AAndrews logo

Andrews E22 Fault Code: Causes, Fixes & Repair Costs

What does the Andrews E22 fault code mean?

The E22 code on an Andrews water heater most likely indicates an ignition or flame detection fault — part of the E2x family of error codes used across the Andrews range (ClassicFlo, HiFlo EVO, EcoFlo, FastFlo and similar models). When the appliance attempts to light, the integrated Honeywell control board either fails to confirm that a flame has been established, or detects a problem with the flame-sensing signal. After a set number of failed ignition attempts, the unit enters a safe lockout and holds the code on the display. Because Andrews does not publish full fault-code lists publicly, always cross-reference with your model's installation manual or Andrews technical support if the description below does not match your symptoms exactly.

Lockout — engineer likely May need a Gas Safe engineer 4 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check that gas is available to other appliances DIY safe

    Turn on a gas hob ring or check another gas appliance. If nothing lights, the problem is with the gas supply rather than the Andrews unit itself. Check your meter is in credit and that the emergency control valve on the gas meter is fully open (handle in line with the pipe).

  2. Check and restore boiler system pressure if applicable DIY safe

    If your Andrews unit is part of a sealed heating system, look at the pressure gauge. It should read between 1 and 1.5 bar when cold. If it is below 1 bar, top it up using the filling loop and refer to the user guide for your specific model. Note: many Andrews water heaters are open-vented or direct-fired and do not have a filling loop — skip this step if yours has no pressure gauge.

  3. Check for a frozen condensate pipe in cold weather DIY safe

    In temperatures below 0 °C, a plastic condensate pipe running outside the building can freeze solid, causing the appliance to lock out. If you can safely reach the pipe, thaw it by pouring warm (not boiling) water along its length or by applying a heat wrap. Once clear, attempt a reset.

  4. Reset the appliance once DIY safe

    Press and hold the reset button (or turn the reset knob, depending on your Andrews model) as described in your user guide. Allow the unit a full ignition cycle — typically 30 to 60 seconds — before deciding whether it has lit successfully. If it locks out again immediately or within a short time, do not keep resetting; repeated resets without fixing the underlying fault can damage components and mask the true problem.

  5. Have a Gas Safe engineer clean or replace the flame-sensing electrode Gas Safe engineer

    An engineer will remove the burner assembly, inspect the sensor rod for carbon fouling or tip erosion, and either clean it with a fine abrasive or replace it. This is one of the most cost-effective fixes for E2x lockouts and is often carried out during an annual service visit.

  6. Have a Gas Safe engineer inspect and test the ignition electrode and lead Gas Safe engineer

    The engineer will check the electrode gap, look for cracks in the ceramic body, and test the ignition lead for continuity and insulation breakdown. Worn electrodes and cracked leads are straightforward, relatively inexpensive parts to replace.

  7. Have a Gas Safe engineer test the gas valve Gas Safe engineer

    Using a gas analyser and pressure gauge, the engineer will verify that the valve opens correctly and delivers the right gas rate to the burner. A valve that is stuck, slow to open, or passing insufficient gas will require replacement — this is a notifiable gas-safety repair that must be carried out by a Gas Safe registered person.

  8. Have a Gas Safe engineer inspect the fan and air-proving switch Gas Safe engineer

    The engineer will check fan speed, look for worn bearings, and test the differential pressure switch that signals the board when airflow is established. A faulty fan or switch that prevents the pre-purge cycle completing will cause repeated lockouts.

  9. Have a Gas Safe engineer test the PCB and consider replacement if all other components pass Gas Safe engineer

    If electrodes, gas valve, fan, and flue all check out, the control board itself may be generating a false lockout or failing to produce a spark trigger. PCB diagnosis requires specialist test equipment; replacement is the usual outcome if the board is confirmed faulty.

  10. Call a Gas Safe registered engineer with Andrews commercial water heater experience Gas Safe engineer

    If you have not already done so, book a Gas Safe registered engineer — ideally one familiar with Andrews or Honeywell-controlled commercial water heaters. Note down the full code as it appears on the display, the model number (usually on a data plate inside the front panel), and any pattern to when the fault occurs (e.g. first thing in the morning, after a period of inactivity). This information helps the engineer diagnose quickly and arrive with the right parts.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£380, depending on the underlying cause.

Frequently asked questions

Is E22 definitely an ignition fault on my Andrews water heater?

Andrews does not publish its full fault-code list openly, so E22 cannot be confirmed without consulting the manual for your specific model. That said, the E2x range of codes on Andrews appliances running Honeywell integrated controls is consistently associated with ignition and flame-detection faults. Check the data plate inside the front panel for your exact model, then call Andrews technical support (andrewswaterheaters.co.uk) or a Gas Safe engineer experienced with Andrews units if the description on this page does not match what your appliance is doing.

Can I fix Andrews E22 myself?

A handful of preliminary checks are safe for a homeowner: confirming gas reaches other appliances, topping up system pressure if the unit is on a sealed system and pressure is low, thawing a frozen condensate pipe in winter, and pressing reset once. Beyond that, every internal repair — cleaning or replacing electrodes, testing the gas valve, inspecting the flue or fan — must be done by a Gas Safe registered engineer. Andrews explicitly requires that all service work is carried out by qualified personnel.

How much will it cost to repair Andrews E22?

For the most common causes — electrode cleaning or replacement and related labour — most people pay in the region of £120 to £250 all in. If the gas valve needs replacing, expect £280 to £380 once parts and labour are combined. A PCB replacement is at the top of the typical range and can exceed £400 to £500 depending on the specific board and engineer's call-out fee, though this is a less common outcome. Getting an annual service (roughly £80 to £150) is the best way to catch electrode wear before it causes a lockout.

How do I stop Andrews E22 from coming back?

The most effective prevention is an annual service by a Gas Safe engineer familiar with Andrews units. During a service the engineer will clean or replace the flame sensor and ignition electrode, check gas pressure and combustion quality, and inspect the flue — addressing the root causes of E2x lockouts before they put the unit into lockout. Keeping the area around the air intake clear of debris and ensuring the flue terminal outside is unobstructed also reduces the risk of airflow-related ignition failures.

Affected models: Andrews ClassicFlo, Andrews HiFlo EVO, Andrews EcoFlo, Andrews FastFlo

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Andrews E22 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →