AAriston logo

Ariston 202 Fault Code: Causes, Fixes & Repair Costs

What does the Ariston 202 fault code mean?

Ariston fault code 202 belongs to the 200-series, which covers domestic hot water (DHW) circuit sensor faults. On most Ariston boilers, code 202 points to a short circuit on the DHW flow or temperature sensor — the component that detects when you open a hot tap and tells the PCB to fire the burner. When this sensor develops an electrical fault, the boiler cannot operate safely and will typically lock out, cutting off your hot water supply. On Evo-range models (Clas HE evo, Clas HE evo System, E-combi evo, and E-system evo), the same code instead relates to a fault with the bottom storage temperature probe, which monitors the temperature in the lower section of a stored hot water vessel. A small number of sources also associate code 202 with a flame detection or ignition lockout on certain variants. Because Ariston applies this code slightly differently across its product range, always check your boiler's specific manual if you are unsure which interpretation applies to your unit.

Lockout — engineer likely May need a Gas Safe engineer 8 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Reset the boiler once DIY safe

    Locate the reset button on your boiler's control panel — on most Ariston models it is labelled with a flame and cross symbol or a circular arrow. Press and hold it for approximately five seconds until the boiler attempts to restart. Allow it to complete its ignition sequence before judging whether the fault has cleared. If code 202 reappears immediately or returns within a short time, do not continue resetting, as repeated resets can mask a worsening problem and in rare cases cause additional wear.

  2. Check that your gas supply is working DIY safe

    Confirm that other gas appliances in your home — such as a gas hob or fire — are working normally. If they are not, contact your gas supplier, as the issue may be an interrupted supply rather than a boiler fault. Do not attempt to investigate gas pipework yourself.

  3. Note the exact boiler model and code variant DIY safe

    Find your boiler's model name on the front casing or inside the front panel. This tells you whether you have an Evo-range model (which uses code 202 for the bottom storage probe) or another Ariston model (where 202 means a DHW sensor short circuit). Pass this information to the engineer you contact — it will speed up diagnosis and parts ordering.

  4. Have a Gas Safe engineer inspect the sensor wiring and connections Gas Safe engineer

    An engineer will access the internal wiring loom and check the connectors leading to the DHW flow or temperature sensor. Loose, corroded, or chafed connectors are a common and relatively quick fix. The engineer will also verify that no other components on the same circuit are contributing to the fault.

  5. Have the sensor tested electrically and replaced if necessary Gas Safe engineer

    Using a multimeter, the engineer will measure the sensor's resistance and compare it to the manufacturer's specification. A sensor reading outside tolerance confirms it has failed and must be replaced. On Evo models, the bottom storage probe will be tested in the same way. Replacement sensors are straightforward to fit but require draining part of the system and correctly re-pressurising afterwards.

  6. Ask the engineer to inspect the PCB if the fault persists after sensor replacement Gas Safe engineer

    If a new sensor does not clear the fault, the problem may lie with the printed circuit board (PCB), which processes the sensor's signal. PCB diagnosis and replacement is specialist work and should only be carried out by a Gas Safe registered engineer. This is a less common outcome but worth raising if the initial repair does not resolve the lockout.

  7. Call a Gas Safe registered engineer Gas Safe engineer

    If the boiler remains in lockout after a single reset attempt, contact a Gas Safe registered engineer to carry out a proper diagnosis. You can verify an engineer's registration at gassaferegister.co.uk. Attempting internal repairs yourself on a gas appliance is illegal and dangerous.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£300, depending on the underlying cause.

Frequently asked questions

Will Ariston fault code 202 clear itself, or does it need a reset?

Code 202 is a lockout fault, which means the boiler has shut down and will not restart on its own. You can try pressing the reset button once to see if it was a one-off glitch. If the fault returns, the underlying sensor or wiring problem needs to be diagnosed and repaired by a Gas Safe engineer before the boiler will run reliably again.

My boiler is an Ariston Clas HE evo — does code 202 mean the same thing?

Not quite. On the Evo range (Clas HE evo, Clas HE evo System, E-combi evo, and E-system evo), code 202 relates to the bottom storage temperature probe rather than the standard DHW flow sensor. The repair process is similar — an engineer will test the probe electrically and replace it if it has failed — but the probe is located differently, so it is worth telling your engineer which model you have before they arrive.

How much does it cost to fix Ariston fault code 202 in the UK?

For a straightforward sensor or probe replacement, most homeowners pay in the region of £120 to £300 all-in, covering the call-out, labour, and the part itself. If the wiring loom also needs attention the bill may sit towards the upper end of that range. In the less common situation where the PCB is also found to be faulty, costs can rise to £350–£500 or more — but this is not the typical outcome for a code 202 fault.

Is there anything I can do myself before calling an engineer for code 202?

Your options as a homeowner are limited to one reset attempt and confirming that other gas appliances in your home are working (to rule out a gas supply interruption). The sensor, its wiring, and all internal boiler components must be inspected and replaced by a Gas Safe registered engineer. Attempting to access or repair these parts yourself is not permitted under UK gas safety legislation.

Affected models: Ariston Clas HE, Ariston Clas HE evo, Ariston Clas HE evo System, Ariston E-combi evo, Ariston E-system evo, Ariston Genus, Ariston Alteas, Ariston Egis Plus

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Ariston 202 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.