AATAG logo

ATAG 129 Fault Code: Causes, Fixes & Repair Costs

What does the ATAG 129 fault code mean?

Fault code 129 on ATAG boilers indicates that the boiler's fan has failed to start up. When the fan cannot spin up to the required speed, the boiler locks out as a safety precaution and refuses to fire. You may notice a bell symbol displayed alongside the code 129 on the boiler — this confirms the unit is in lockout and needs a reset and/or engineer intervention to clear. If you have an ATAG digital programmer plugged in, it will display a sub-code alongside 129 that points to the specific nature of the fan fault — for example, sub-code 2 indicates 'fan failure — low RPM', meaning the fan is spinning but cannot reach the speed required for safe combustion. A related but separate code, 151, covers situations where the fan starts but cannot maintain or achieve the correct speed range, or where there is a control unit fault — so if you are seeing 151 rather than 129, the fan itself may be partially operational but not reliably controlled.

Lockout — engineer likely May need a Gas Safe engineer 4 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check your gas supply is working DIY safe

    Confirm other gas appliances in the property — such as a gas hob — are working normally. If you have no gas supply at all, contact your gas supplier rather than an engineer.

  2. Attempt a boiler reset DIY safe

    Press and hold the reset button on the boiler control panel as described in your user guide. The boiler will attempt to restart. If it locks out again with code 129, do not reset more than two or three times in quick succession as this can cause further issues. A persistent 129 after resetting confirms an engineer is needed.

  3. Inspect the external flue terminal for obvious blockage DIY safe

    From outside, visually check that the flue outlet and air intake are not obstructed by leaves, bird nesting material, or other debris. Do not attempt to dismantle anything — this is a visual check only. If you spot a blockage you cannot safely remove from outside, report it to your engineer.

  4. Engineer to test fan wiring and connections Gas Safe engineer

    A Gas Safe engineer will use a multimeter to check continuity and voltage across the wiring harness between the PCB and the fan motor. Loose, corroded, or broken connectors will be tightened or replaced at this stage.

  5. Engineer to inspect and test the fan motor and capacitor Gas Safe engineer

    The engineer will physically inspect the fan blades for obstructions and bearing wear, then electrically test the motor and any associated capacitor. If the motor is seized or the capacitor has failed, the relevant component will be replaced.

  6. Engineer to test PCB output signals Gas Safe engineer

    If the fan motor and wiring both test as sound, the engineer will check whether the PCB is correctly sending drive signals to the fan. A faulty PCB will need repair or replacement by a qualified professional.

  7. Call a Gas Safe registered engineer if the fault persists Gas Safe engineer

    All internal boiler work on gas appliances is legally required to be carried out by a Gas Safe registered engineer in the UK. If your boiler is still within its warranty period, contact ATAG directly on 0800 680 0100 before arranging a third-party repair, as warranty work is carried out by ATAG's own engineers at no charge.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£350, depending on the underlying cause.

Frequently asked questions

Can I fix ATAG fault code 129 myself?

The only safe steps a homeowner can take are checking the gas supply is on, looking at the external flue for obvious blockages, and attempting a reset once or twice. Everything else — testing the fan motor, replacing components, or working on wiring inside the boiler — must be carried out by a Gas Safe registered engineer. Attempting internal boiler work without registration is illegal in the UK and can be dangerous.

How much does it cost to fix a 129 fault on an ATAG boiler?

For most people, the repair falls somewhere between £120 and £350 depending on what is found. A wiring or connection fix is typically at the lower end, while a full fan assembly replacement usually comes in around £225–£275 all-in including labour. If the PCB is also at fault, costs can rise considerably — PCB replacement on ATAG boilers tends to be in the region of £400–£500 — though this is less common. If your boiler is approaching 10–15 years old and needs a major component, it is worth getting a new boiler quote alongside the repair quote.

What is the difference between ATAG fault codes 129 and 151?

Both codes relate to the fan but indicate different failure modes. Code 129 means the fan has not started at all — the boiler cannot detect any rotation when it tries to fire. Code 151 means the fan starts but cannot reach or maintain the correct speed range, or there is a control unit fault affecting speed regulation. In practice, 129 is more often a mechanical or electrical failure of the fan motor or its wiring, while 151 can sometimes point toward a PCB or speed-control issue. An engineer will diagnose which components are at fault in either case.

My ATAG boiler is still under warranty — do I need to pay for this repair?

ATAG offers a 10-year manufacturer warranty on many of their boilers, and during this period they send their own engineers to diagnose and fix faults at no cost to you (subject to warranty terms and conditions). Before booking and paying for an independent Gas Safe engineer, call ATAG directly on 0800 680 0100 to check whether your boiler is still covered. Have your boiler model and installation date to hand.

Affected models: ATAG iC Economiser, ATAG iC Range, ATAG iC One, ATAG Q Series

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: ATAG 129 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.