ATAG 1P4 Fault Code: Causes, Fixes & Repair Costs

What does the ATAG 1P4 fault code mean?

The 1P4 fault code on an Atag boiler (also displayed as F1P4 or fault code 108) indicates that the system water pressure has dropped below 0.8 bar — the minimum threshold the boiler needs to operate safely. When your central heating system loses pressure, the boiler locks out as a protective measure rather than run dry. In most cases this is a straightforward fix: the system simply needs topping up via the filling loop to bring pressure back into the correct cold-fill range of 1.0–1.1 bar. Once the system heats up, it is normal for pressure to climb to around 1.8–2.4 bar — this is just water expanding with heat. However, if pressure drops repeatedly, an underlying fault such as a water leak, a weeping pressure relief valve, or a faulty pressure sensor is likely and will need professional attention.

Lockout — engineer likely Some DIY checks possible 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the boiler pressure gauge DIY safe

    Look at the pressure gauge on the front or underside of the boiler. A reading below 1.0 bar when the system is cold confirms low pressure is the cause of the 1P4 fault. If the gauge reads 1.0 bar or above, the fault may point to a sensor issue rather than genuinely low pressure — skip to the engineer step.

  2. Locate the filling loop and repressurise the system DIY safe

    The filling loop is typically a short, braided flexible hose with one or two small valve handles, usually found beneath the boiler. Slowly open the valve(s) by a quarter-turn — you should hear water entering the system. Watch the pressure gauge rise and stop filling once it reaches 1.0–1.1 bar. Close the valve(s) fully. Do not overfill past 1.5 bar; if you do, bleed a small amount of water from a radiator bleed valve to bring the pressure back down.

  3. Reset the boiler DIY safe

    Press and hold the reset button on the boiler control panel (typically marked with a flame symbol or the word 'Reset') for 3–5 seconds, then release. The boiler should attempt to restart. Allow a few minutes for it to complete its start-up sequence and check whether the 1P4 code has cleared.

  4. Check for visible leaks around the system DIY safe

    While the boiler restarts, take a few minutes to inspect radiator valve connections, any visible pipework, and the area directly beneath the boiler for damp patches, rust staining, or limescale deposits. If you spot active drips or wet patches, do not keep repressurising — switch the boiler off and call a Gas Safe engineer, as topping up a leaking system will only mask the problem.

  5. Monitor the pressure over the following days DIY safe

    Once running normally, keep an eye on the pressure gauge over the next 48–72 hours. A pressure that remains stable suggests a one-off top-up was all that was needed. If the reading drops again within a few days, there is an ongoing leak or component fault that needs professional investigation.

  6. Call a Gas Safe registered engineer if the fault persists or pressure keeps dropping Gas Safe engineer

    If the 1P4 code returns after repressurising, if you cannot locate the filling loop, if pressure is falling repeatedly, or if you suspect a PRV, sensor, or internal component fault, contact a Gas Safe registered engineer. They can pressure-test the system to find hidden leaks, test the pressure sensor, inspect the PRV, and investigate any underlying circulation or sensor faults that may be contributing to the lockout.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £80–£300, depending on the underlying cause.

Frequently asked questions

Can I fix the Atag 1P4 fault myself without calling an engineer?

In many cases, yes. If the pressure gauge shows below 1.0 bar, repressurising the system via the filling loop and resetting the boiler is a straightforward DIY task that costs nothing. However, if pressure keeps dropping after you top it up, or if you cannot identify a filling loop, you should call a Gas Safe engineer — repeatedly topping up a leaking system is not a fix.

What pressure should my Atag boiler be at?

When the system is cold, the pressure should sit between 1.0 and 1.1 bar. As the water heats up it expands, so a reading of 1.8–2.4 bar when the heating is running is entirely normal. If the cold pressure is consistently below 0.8 bar, the boiler will lock out and display the 1P4 fault.

Why does my Atag boiler keep losing pressure and showing 1P4?

If you are topping up the system more than once every couple of months, there is almost certainly a leak somewhere. Common culprits include a weeping pressure relief valve (look for a trickle from the external overflow pipe), a dripping radiator valve, a loose pipe joint, or a failing expansion vessel. A Gas Safe engineer can carry out a proper pressure test to pinpoint the source. Ignoring a persistent pressure loss can lead to more expensive damage over time.

Could the 1P4 fault be caused by something more serious than low pressure?

Usually not — the vast majority of 1P4 faults are simply low water pressure, fixed by a quick top-up. However, in rare cases a faulty pressure sensor can trigger the code even when actual pressure is adequate, and a pattern of three successive flow-check failures leading to a 1P4 lockout can indicate a circulation problem or temperature sensor fault. If your boiler is locking out repeatedly or showing other fault codes alongside 1P4, have a Gas Safe engineer carry out a full diagnostic. If a component like the PCB ever needs replacement, costs can rise to £400 or more — though this is uncommon for a pressure-related fault.

Affected models: Atag iC Economiser+, Atag iC FIVE, Atag iR FIVE, Atag Q Series, Atag A Series

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: ATAG 1P4 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →