BBaxi logo

Baxi E.04-.12 Fault Code: Causes, Fixes & Repair Costs

What does the Baxi E.04-.12 fault code mean?

The E.04-.12 code is a permanent safety lockout on Baxi boilers, triggered when the control board detects a flame signal at a time when no flame should be present — or when combustion is behaving erratically. Because the boiler's ionisation circuit is reporting a flame that cannot be accounted for, the appliance shuts itself down immediately as a precaution. Unlike some soft faults that clear on their own, this is a permanent lockout: the boiler will stay off until the root cause is resolved and the fault is manually reset. Typical culprits include a faulty or contaminated flame-sensing electrode, a problem with the gas-air mixing unit (sometimes called a venturi), a defective gas valve, excessively high CO2 in the flue gases due to poor combustion, or in some cases a brief mains voltage fluctuation that confused the control board. Because gas combustion is directly involved, a Gas Safe registered engineer should be contacted promptly once basic homeowner checks have been completed.

Lockout — engineer likely May need a Gas Safe engineer 9 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check your gas supply is active DIY safe

    Confirm the gas isolation valve behind or near the boiler is fully open (handle in line with the pipe). Test another gas appliance — a hob burner or gas fire — to verify supply is reaching your home. If there is no gas supply at other appliances, contact your gas supplier rather than your boiler engineer.

  2. Reset the boiler once DIY safe

    Press and hold the reset button (or turn the reset dial to the reset position, depending on your model) for a few seconds until the boiler attempts to restart. Allow the ignition sequence to complete. Only attempt this once or twice at most — repeated resets on a gas-combustion lockout can mask a developing fault and are not safe practice.

  3. Check for a frozen condensate pipe (cold weather only) DIY safe

    In freezing conditions, the plastic condensate pipe running from the boiler to an outside drain or soakaway can block with ice, preventing the boiler from firing. The pipe is typically 21–32 mm white or grey plastic. If it feels solid or you can see ice, gently pour warm (not boiling) water along its length to thaw it, then attempt a reset. Boiling water can crack the plastic and cause a leak.

  4. Do not attempt further resets if the fault returns DIY safe

    If the E.04-.12 code reappears after a reset, stop cycling the boiler. Repeated attempted starts on a false-flame fault will not resolve the underlying problem and could complicate the engineer's diagnosis.

  5. Have a Gas Safe engineer inspect and clean the ionisation electrode Gas Safe engineer

    An engineer will remove the burner assembly, visually inspect the flame-sensing probe for carbon fouling or cracking, clean it carefully, check the probe gap against the manufacturer's specification, and replace it if it is damaged. This is frequently all that is needed to clear a persistent E.04-.12.

  6. Engineer to test and verify gas-air unit and gas valve operation Gas Safe engineer

    Using a flue-gas analyser, the engineer will measure CO2 output and check that the gas-air unit (venturi) is delivering the correct mixture ratio. They will also electrically test the gas valve coils and check for correct opening and closing. Any component outside specification will be replaced.

  7. Engineer to inspect PCB and wiring loom Gas Safe engineer

    If the combustion components test correctly, the engineer will check the wiring connectors at the gas valve and the PCB for corrosion, chafing, or loose terminals. If the PCB is generating a false ionisation signal internally, it will need to be replaced.

  8. Call a Gas Safe registered engineer if not already done Gas Safe engineer

    Because E.04-.12 involves a gas combustion safety lockout, all diagnostic and repair work beyond basic homeowner checks must be carried out by a Gas Safe registered engineer. You can verify an engineer's registration at gassaferegister.co.uk. Do not leave the boiler running repeatedly in lockout and do not attempt to bypass any safety devices.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£350, depending on the underlying cause.

Frequently asked questions

Can I reset a Baxi E.04-.12 fault myself or do I need an engineer?

You can attempt a single manual reset after checking the gas supply is on and — in winter — ruling out a frozen condensate pipe. If the lockout clears and does not return, monitor the boiler closely. However, because E.04-.12 is a gas combustion fault caused by a false flame signal, it almost always indicates a faulty electrode, gas-air unit, or gas valve that requires a Gas Safe engineer to properly diagnose and repair. Repeated resetting without fixing the root cause is not recommended.

How much does it typically cost to repair a Baxi E.04-.12 fault in the UK?

For the most common repairs — cleaning or replacing the ionisation electrode, or replacing the gas valve — most homeowners pay somewhere between £100 and £350 including call-out, labour, and parts. If the gas-air unit needs replacing the bill can reach the higher end of that range. A PCB replacement is less common but can add £300–£500 on top; if the PCB is the cause and the boiler is over ten years old, it is worth discussing replacement versus repair with your engineer.

What is the gas-air unit on a Baxi boiler and why does it cause this fault?

The gas-air unit (also called the venturi or gas-air ratio unit) is the component that blends gas and air in the correct proportion before they reach the burner. If it wears out or develops a fault, the mixture becomes imbalanced — the burner may run too rich, producing excessive CO2, or combustion may become erratic. The control board picks up the abnormal ionisation reading and triggers an E.04-.12 lockout as a safety measure. Replacement requires a Gas Safe engineer and the part typically costs £150–£300 fitted.

Is the Baxi E.04-.12 fault dangerous?

The boiler has shut itself down precisely because it detected something abnormal about the flame signal, so there is no active combustion danger while the lockout is in place. However, you should not attempt to defeat or repeatedly override the lockout, and you should not attempt any work on the gas valve, burner, or related components yourself. Call a Gas Safe registered engineer promptly — this is not a fault to leave unattended for extended periods.

Affected models: Baxi 200 Combi, Baxi 400 Combi, Baxi 600 Combi, Baxi 800 Combi, Baxi Duo-tec Combi, Baxi Platinum Combi, Baxi EcoBlue Combi, Baxi Megaflo System, Baxi 100 Heat

Last reviewed 2 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Baxi E.04-.12 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →