Buderus 0Y 276 Fault Code: Causes, Fixes & Repair Costs

What does the Buderus 0Y 276 fault code mean?

Fault code 0Y 276 tells you that the boiler's flow temperature sensor has recorded water temperatures above 95°C, prompting the boiler to shut itself down as a safety measure. The broader 0Y code class means the actual flow temperature has climbed higher than the target setpoint, and the boiler cuts out to protect both itself and your heating system from dangerous overheating. In some cases this can happen without a genuine component failure — for instance, if several thermostatic radiator valves (TRVs) are closed at the same time, water has nowhere to circulate and rapidly overheats at the heat exchanger.

Lockout — engineer likely Some DIY checks possible May need a Gas Safe engineer 7 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check that your radiator TRV valves are open DIY safe

    Walk around the property and make sure thermostatic radiator valves are not all turned to the closed or frost-protection position. Open several radiators fully so the pump has adequate flow paths. This costs nothing and resolves the fault surprisingly often.

  2. Check and top up system pressure if needed DIY safe

    Look at the boiler pressure gauge. It should read between 1.0 and 1.5 bar when cold. If it is below 1 bar, use the filling loop to top it up — refer to your boiler manual for the location. Low pressure reduces water flow and can contribute to localised overheating.

  3. Reset the boiler DIY safe

    Press and hold the Reset button for around 5 seconds, or switch the boiler off at the mains for 15 seconds and switch it back on. Do this no more than two or three times. If the fault clears and the boiler fires successfully, monitor it over the next hour. If 0Y 276 returns, move on to the steps below — repeated resets without fixing the root cause will not help and could mask a genuine problem.

  4. Have a Gas Safe engineer test the NTC flow temperature sensor Gas Safe engineer

    An engineer will disconnect the NTC thermistor and test its electrical resistance with a multimeter at known temperatures. A sensor reading out of the expected resistance range indicates it has failed and needs replacing. This is a relatively inexpensive repair and one of the most common fixes for this fault code.

  5. Have the circulation pump inspected and tested Gas Safe engineer

    The engineer can run Buderus service function t03 to observe pump behaviour through the boiler's own diagnostics. They will check the pump's connection cable, listen for signs of a seized impeller, and verify the pump is delivering adequate flow. A seized pump can sometimes be freed; a worn or failed unit will need replacing.

  6. Have the safety thermostat checked Gas Safe engineer

    If the pump and NTC sensor are confirmed healthy, an engineer should check whether the high-limit safety thermostat has tripped or failed. A tripped thermostat may simply need resetting; a faulty one will need replacement.

  7. Have the PCB inspected as a last resort Gas Safe engineer

    If all other components check out, the engineer should examine the control board for signs of heat damage, burnt components, oxidised connectors, or moisture. PCB replacement is the most expensive outcome for this fault, so a methodical engineer will rule out cheaper causes first. Always supply your exact Buderus model designation when sourcing a replacement board.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £90–£380, depending on the underlying cause.

Frequently asked questions

Can I fix Buderus fault code 0Y 276 myself?

The only homeowner-safe actions are opening closed TRV valves, topping up system pressure via the filling loop, and resetting the boiler a couple of times. If those steps do not clear the fault, the cause is almost certainly a failed sensor, pump, or internal component that must be diagnosed and repaired by a Gas Safe registered engineer. Do not attempt to access internal components yourself.

Why does 0Y 276 keep coming back after I reset the boiler?

A recurring 0Y 276 fault means the underlying cause has not been addressed. The most likely culprits are a degraded NTC flow temperature sensor sending false high readings, a circulation pump that is losing efficiency, or TRVs that are restricting flow across large parts of the system. Each reset without a fix puts extra thermal stress on the boiler, so book an engineer rather than continuing to reset.

How much does it typically cost to repair a Buderus 0Y 276 fault in the UK?

Most people with this fault end up paying somewhere between £90 and £380 all-in. An NTC sensor replacement including labour usually costs around £80–£180, while a circulation pump swap typically runs £150–£350 depending on your region and the pump model. If the PCB turns out to be the cause, replacement costs are significantly higher — often £450–£700 — but this is the least common outcome. Engineers in London and the South East generally sit at the top of these ranges, while the North of England and Wales tend to be 10–20% cheaper.

Is it safe to keep using my boiler after seeing fault code 0Y 276?

No — the boiler will have already shut itself down as a safety measure, so it will not produce heat or hot water until the fault is resolved. Do not try to force it back into operation through repeated resets if it keeps locking out. The fault indicates water in the system has reached or approached 95°C, which is genuinely dangerous. Get it looked at promptly.

Affected models: Buderus GB172, Buderus GB192, Buderus GB212, Buderus Logamax Plus GB072, Buderus Logamax Plus GB162, Buderus Logamax U072, Buderus Logano GE315

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Buderus 0Y 276 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →