Chaffoteaux 213 Fault Code: Causes, Fixes & Repair Costs

What does the Chaffoteaux 213 fault code mean?

Fault code 213 on Chaffoteaux boilers sits within the 210-series of codes, which relate to the heating return circuit sensor. Code 213 specifically indicates that the boiler's control board has detected a short circuit or out-of-range reading from the return NTC thermistor — the sensor responsible for monitoring the temperature of water as it comes back into the boiler from the heating system. When this sensor reports an implausible value (zero or near-zero resistance suggests a short circuit; infinite resistance suggests an open circuit or broken connection), the boiler locks out as a safety measure. Related codes in the same series include 211 (return sensor reading too low or open circuit) and 212 (return sensor reading anomaly); 213 is the short-circuit variant. The boiler will not fire until the fault is cleared.

Lockout — engineer likely May need a Gas Safe engineer 8 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Reset the boiler once or twice DIY safe

    Press and hold the reset button on the boiler's front panel as described in your user manual. A single short-circuit spike can occasionally trigger a spurious lockout. If the boiler fires up and runs normally after one or two resets, monitor it closely. If code 213 returns within a short period, move on to further investigation and do not keep resetting — repeated lockouts indicate a genuine fault.

  2. Check system pressure DIY safe

    Look at the pressure gauge on the boiler front. It should read between 1.0 and 1.5 bar when the heating is cold. If it has dropped below 1 bar, top it up via the filling loop until it reaches approximately 1.2 bar, then attempt another reset. Low pressure alone is unlikely to cause code 213, but it is a quick, safe check worth doing before calling an engineer.

  3. Check for obvious moisture around the sensor area DIY safe

    With the boiler switched off and cooled down, visually inspect around the boiler casing for signs of a water leak or heavy condensation near pipework. Do not open the boiler casing or touch any internal components. If you can see dripping water or significant damp, note this when you call an engineer — it may be the root cause of the connector short.

  4. Engineer to test the return NTC sensor resistance Gas Safe engineer

    A Gas Safe registered engineer will disconnect the return NTC thermistor and measure its resistance with a calibrated multimeter. At approximately 25°C, a healthy Chaffoteaux return sensor should read around 8.1–8.6 kΩ. A reading close to 0 Ω confirms a short circuit in the sensor; an open-circuit (infinite) reading confirms a break. Either result means the sensor needs replacing.

  5. Engineer to inspect wiring loom and connectors Gas Safe engineer

    The engineer will also check the wiring between the sensor and the PCB for signs of chafing, melted insulation, corroded pins, or moisture damage. A damaged wire can be repaired or the loom section replaced; corroded connectors should be cleaned or renewed. This step is often done alongside the sensor test and adds little time to the job.

  6. Engineer to replace the return NTC thermistor if faulty Gas Safe engineer

    If the sensor tests outside specification, the engineer will fit a new return NTC thermistor. The compatible Ariston/Chaffoteaux thermistor (part reference 61000733) is a low-cost part, typically under £20 including VAT from UK spare parts suppliers. Once fitted and connected, the engineer will clear the fault, fire the boiler, and verify the return temperature reading is being reported correctly.

  7. Engineer to assess and replace the PCB if the fault persists Gas Safe engineer

    If the sensor and wiring both test correctly but code 213 continues to appear, the PCB's sensor input circuit is likely faulty. The engineer will inspect the board for visible damage and, if required, fit a replacement PCB matched to the boiler model. This is the most expensive outcome and is relatively uncommon for this fault code.

  8. Call a Gas Safe registered engineer Gas Safe engineer

    If the fault does not clear after a reset and basic pressure check, book a Gas Safe registered engineer to diagnose and resolve the fault. You can verify any engineer's credentials at gassaferegister.co.uk. Annual boiler servicing can help catch sensor and wiring issues before they cause a breakdown.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£250, depending on the underlying cause.

Frequently asked questions

Is Chaffoteaux fault code 213 dangerous?

Code 213 is a sensor fault rather than a gas or combustion safety issue, so it does not indicate an immediate danger such as a gas leak or carbon monoxide risk. However, the boiler locks out and will not provide heating or hot water until the fault is fixed. You should still have it looked at promptly by a Gas Safe registered engineer, particularly in cold weather.

Can I fix fault code 213 myself?

The only checks a homeowner can safely carry out are resetting the boiler (once or twice), checking the system pressure and topping up via the filling loop if needed, and looking for obvious signs of moisture or a water leak around the boiler exterior. Any work inside the boiler — testing or replacing the sensor, inspecting wiring, or working on the PCB — must be carried out by a Gas Safe registered engineer. Attempting internal repairs yourself is unsafe and could invalidate your warranty or home insurance.

How much does it cost to fix a Chaffoteaux 213 fault in the UK?

For most people this fault is resolved by replacing the return NTC sensor, which is a cheap part (around £10–£20). Combined with a standard Gas Safe engineer callout and labour, the total is typically £100–£200. If the wiring loom also needs attention, costs sit toward the upper end of that range. In the less common scenario where the PCB is at fault, expect to pay £250–£450 for a board replacement including labour. Always get at least two quotes for PCB work, and consider the age and overall condition of the boiler before committing to an expensive repair.

What is the difference between Chaffoteaux fault codes 211, 212, and 213?

All three codes are in the 210-series, which covers the heating return circuit temperature sensor. Code 211 typically indicates the sensor is reading an abnormally low temperature or an open circuit (broken connection or failed sensor with very high resistance). Code 212 indicates a general sensor anomaly or out-of-range reading. Code 213 specifically points to a short circuit in the return sensor circuit — where the resistance has collapsed toward zero, suggesting the sensor or its wiring has shorted. The diagnostic and repair approach is very similar for all three: an engineer tests the sensor resistance and inspects the wiring before deciding whether to replace the sensor, the loom, or in rare cases the PCB.

Affected models: Talia Green, Talia System, Inoa, Inoa System, Pigma, Pigma System, Expert Control, Celtic HE

Last reviewed 15 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Chaffoteaux 213 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →