Chaffoteaux 620 Fault Code: Causes, Fixes & Repair Costs

What does the Chaffoteaux 620 fault code mean?

Fault code 620 on a Chaffoteaux boiler indicates a problem within the fan and flue airflow system. The boiler's control board has detected that the fan and air pressure switch are not communicating correctly — for example, the fan may be running but failing to generate the expected pressure change that triggers the air pressure switch, or a flue-related sensor is returning an out-of-range reading. As a safety precaution the boiler locks out to prevent combustion gases from building up. Code 620 sits within Chaffoteaux's 600-series fault family, which covers all flue gas, fan, and airflow-related issues. Related codes in the same family include 601 (flue gas sensor anomaly), 610 (thermal fuse open, typically due to overheating), and 612 (general fan anomaly). If your display shows one of those instead, the diagnostic process is very similar to what is described here.

Lockout — engineer likely May need a Gas Safe engineer 7 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Reset the boiler once DIY safe

    Locate the reset button on your Chaffoteaux boiler (usually marked with a flame or reset symbol on the fascia) and hold it for the required time as shown in your user manual. Wait a full two minutes for the boiler to attempt a restart. If it fires up and runs normally, monitor it closely over the next day or two. If the fault returns, do not keep resetting — repeated resets without fixing the underlying cause can cause further damage.

  2. Check your gas supply DIY safe

    Make sure the gas isolation valve on the supply pipe to the boiler is fully open (handle in line with the pipe). Then check whether other gas appliances in the property — the hob, for instance — are working normally. If no gas appliances are working, contact your gas supplier rather than an engineer.

  3. Inspect the external flue terminal for obstructions DIY safe

    Go outside and look at the flue outlet on the wall or roof. Check for anything that could be restricting airflow: bird nests, leaves, ice, or damage to the terminal cowl. If you can safely reach the terminal and there is a clear physical obstruction such as a nest or ice, remove it carefully. Do not probe inside the flue or attempt to remove the terminal itself.

  4. Check the condensate pipe in cold weather DIY safe

    In freezing temperatures, the external section of the white plastic condensate pipe can freeze solid, which can cause related boiler lockouts. If you suspect this, gently pour warm (not boiling) water over the external section of the pipe until it flows freely, then reset the boiler. Note that a frozen condensate pipe typically triggers its own specific fault code, but it is worth ruling out.

  5. Call a Gas Safe registered engineer to diagnose and repair the fault Gas Safe engineer

    All internal inspection and repair work on a Chaffoteaux boiler must be carried out by a Gas Safe registered engineer. The engineer will test the fan motor and measure its speed, inspect the air pressure switch and replace it if the diaphragm has failed, check the pressure switch tubing for cracks or blockages, test the flue NTC sensor, inspect wiring connections to the fan and PCB, and clear or replace any faulty components. Ask to see the engineer's Gas Safe ID card before work begins. You can verify registration at gassaferegister.co.uk.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £130–£380, depending on the underlying cause.

Frequently asked questions

Is fault code 620 dangerous — should I leave the house?

The boiler has locked itself out as a safety measure, so combustion is not taking place and there is no immediate danger from carbon monoxide while the boiler is in lockout. You do not need to evacuate. However, you should not attempt to override the lockout or keep resetting the boiler repeatedly, as this could bypass safety systems. Get it looked at by a Gas Safe engineer promptly — do not leave it weeks. If you smell gas at any point, leave the property immediately, do not operate any switches, and call the National Gas Emergency Service on 0800 111 999.

Can I fix a Chaffoteaux 620 fault myself?

The only checks a homeowner can safely carry out are: a single reset, confirming the gas supply is on, looking at the external flue terminal for obvious blockages, and thawing a frozen condensate pipe in cold weather. Everything else — testing the fan, replacing the air pressure switch, checking sensor wiring, or touching the PCB — must be done by a Gas Safe registered engineer. Attempting internal boiler repairs without Gas Safe registration is illegal under UK gas safety regulations and invalidates your home insurance.

How much does it typically cost to fix a Chaffoteaux 620 fault?

For most homeowners the repair falls between £130 and £380 including parts and labour. A straightforward air pressure switch or sensor replacement sits toward the lower end, while a full fan motor replacement with a standard call-out tends to land in the £200–£350 range. A PCB replacement is less common but significantly more expensive — typically £350–£550 including labour — and should only be confirmed as necessary after the fan, switch, tubing, and wiring have all been tested and found to be in order. Engineers in London and the South East generally charge 10–15% more than the national average.

My Chaffoteaux shows code 620 only on cold or windy days — is that normal?

This is a recognised pattern. Strong wind blowing directly into the flue terminal can momentarily reverse the airflow and cause the air pressure switch to trip, triggering a 620 lockout. Similarly, in very cold weather, a partially blocked or poorly insulated flue can restrict airflow enough to trigger the fault. A single reset may clear it temporarily, but recurring weather-related faults usually indicate that the flue terminal cowl is worn or poorly sited, or that an underlying component such as the fan or pressure switch is marginal and only fails under adverse conditions. An engineer can assess whether the terminal needs replacing or repositioning.

What is the difference between codes 601, 610, 612, and 620 on a Chaffoteaux boiler?

All four codes belong to the 600-series, which covers the flue gas and airflow system. Code 601 points specifically to a fault with the flue gas sensor (the NTC that monitors exhaust temperature). Code 610 indicates the thermal fuse has blown, usually because a component overheated. Code 612 is a general fan anomaly — the PCB has detected the fan is not operating correctly. Code 620 is most closely associated with the interaction between the fan and the air pressure switch — the fan may be running but not generating the expected airflow signal, or the switch itself has failed. In practice there is some overlap in symptoms, and a Gas Safe engineer will test all these components together to pinpoint the exact cause.

Affected models: Chaffoteaux Pigma, Chaffoteaux Inoa, Chaffoteaux Talia, Chaffoteaux Urbia, Chaffoteaux Britony, Chaffoteaux Expert Control, Chaffoteaux Celtic

Last reviewed 15 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Chaffoteaux 620 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →