Chaffoteaux 704 Fault Code: Causes, Fixes & Repair Costs

What does the Chaffoteaux 704 fault code mean?

Fault code 704 on Chaffoteaux boilers indicates a problem with the return temperature sensor (NTC thermistor) on heating zone 3. This sensor monitors the temperature of water coming back to the boiler after it has circulated through the zone 3 heating circuit, helping the boiler maintain safe and efficient operation. When the boiler's control board receives a reading from this sensor that falls outside the expected range — or receives no signal at all — it logs code 704 and may lock out. Because zone 3 is specific to multi-zone installations, this fault is most commonly seen on Chaffoteaux models fitted with external zone modules (such as the Alixia, Inoa, Talia, and Pigma ranges) rather than straightforward single-zone combis. Codes 701–703 cover flow probe faults on zones 1–3 respectively, so if you are also seeing those codes it can help narrow down whether the issue lies with wiring, a zone module, or the main PCB.

Lockout — engineer likely May need a Gas Safe engineer 4 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Reset the boiler once or twice DIY safe

    Press the reset button on the boiler's front panel and allow a full restart cycle. If the fault clears and does not return within a day or two, the trigger may have been a temporary electrical glitch. Do not reset more than two or three times in quick succession — repeated resets without a successful start can indicate a genuine fault that needs attention.

  2. Check that the mains power supply is stable DIY safe

    Confirm the boiler's fused spur is switched on and the fuse has not blown. If you have a known problem with power surges in your property, mention this to your engineer, as a surge-protection device on the boiler's supply could help prevent recurrence.

  3. Visually inspect accessible sensor wiring (do not open the boiler casing) DIY safe

    Without removing any boiler panels, look at the wiring loom running to the zone module (if externally mounted) for obvious signs of damage — scorching, pinched cables, or connectors that have worked loose. Note anything unusual and report it to your engineer. Do not disconnect or reconnect any wiring yourself.

  4. Arrange for a Gas Safe engineer to test the zone 3 return NTC sensor Gas Safe engineer

    A qualified engineer will disconnect the sensor connector and measure its resistance with a multimeter. A healthy sensor reads around 8.1–8.6 kΩ at 25°C. A reading of zero, open circuit, or well outside the expected range confirms sensor failure. The engineer will also inspect the connector pins for oxidation and clean or replace them as needed.

  5. Have the engineer inspect and test the zone module and wiring harness Gas Safe engineer

    If the sensor tests within spec, the engineer will trace the circuit back through the zone module (where fitted) and on to the PCB, checking for continuity, correct polarity, and signs of heat damage or moisture ingress in the connector block.

  6. PCB inspection and replacement if required Gas Safe engineer

    Should both the sensor and wiring prove serviceable, the main PCB or zone expansion board must be assessed for burnt components, damaged tracks, or swollen capacitors. PCB repair or replacement is specialist work and must only be carried out by a qualified engineer using parts appropriate for the specific boiler model.

  7. Call a Gas Safe registered engineer if you have not already done so Gas Safe engineer

    All internal boiler diagnostics and repairs on a gas appliance must be carried out by a Gas Safe registered engineer under the Gas Safety (Installation and Use) Regulations 1998. You can verify any engineer's registration at gassaferegister.co.uk. If fault code 704 persists after a reset, book a visit promptly rather than continuing to run the boiler.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£300, depending on the underlying cause.

Frequently asked questions

Is fault code 704 dangerous — should I turn the boiler off?

Code 704 is an electrical sensor fault rather than a gas or combustion issue, so it is not an immediate safety emergency in the way that a carbon monoxide alarm or gas smell would be. However, the boiler will usually lock out automatically to protect itself. Leave it locked out and arrange an engineer visit — do not attempt to keep resetting it indefinitely, as this can mask an underlying problem.

How much does it typically cost to fix a Chaffoteaux 704 fault?

In most cases the repair involves replacing the zone 3 return NTC sensor, which is an inexpensive part. Including a call-out fee and labour you would typically expect to pay £100–£300 for a sensor swap. If the fault turns out to be the PCB or zone expansion module, costs rise considerably — a PCB replacement can run to £450–£700 all in — but this is a much less common outcome. Always get a firm quote before authorising any parts.

Can I replace the NTC sensor myself to save money?

Although NTC sensors are straightforward electrical components, replacing one inside a gas boiler requires access to the boiler's internals and work on components connected to a live gas appliance. In the UK this must only be done by a Gas Safe registered engineer. Attempting it yourself is illegal under the Gas Safety (Installation and Use) Regulations 1998 and would invalidate your boiler warranty and home insurance.

Why does my Chaffoteaux only show code 704 on a multi-zone system?

The 700-series fault codes on Chaffoteaux boilers relate specifically to zone temperature sensors. Codes 701–703 cover the flow probes for zones 1–3, while code 704 is the zone 3 return sensor. Single-zone combis do not have a zone 3 circuit, so this fault only appears on installations that use external zone modules to serve separate heating circuits — for example, a property where underfloor heating and radiators run as distinct zones.

Affected models: Chaffoteaux Alixia, Chaffoteaux Inoa, Chaffoteaux Talia, Chaffoteaux Pigma

Last reviewed 15 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Chaffoteaux 704 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →