Johnson & Starley 43
Code 43 on a Johnson & Starley warm-air unit points to a short circuit on the return air temperature sensor — the probe measuring the temperature of air being drawn back into the heater from the house. The controller uses this reading to manage heat output and fan behaviour; a sensor shorted (typically to earth, or across its own conductors) returns an impossible value, so the unit flags code 43. The documented action is to inspect the wiring connections and check the sensor's resistance. Its neighbouring code 44 covers the return sensor's other failure modes (open or short on the central-heating return on combined models), making 43/44 a diagnostic pair around return-side temperature sensing.
Causes, fixes & costs for Johnson & Starley 43 → · All Johnson & Starley codes