Sime AL 10
When your Sime boiler displays AL 10, it has detected a problem with the central heating flow NTC (Negative Temperature Coefficient) thermistor — the small temperature-sensing component mounted on the CH flow pipework inside the boiler. This sensor continuously feeds water-temperature readings to the PCB so the boiler can regulate heat output accurately, typically targeting between 60–80°C for a central heating circuit. If the PCB receives a reading that falls outside expected parameters — whether due to an open circuit, a short circuit, or a value that simply doesn't make sense — it classifies this as a sensor fault, displays 'AL' followed by '10' on the screen, turns the light bar red, and locks the boiler out as a safety precaution. The boiler will not fire until the underlying fault is resolved and the unit is reset.