Baxi E.04-.05
The Baxi E.04-.04 and E.04-.05 fault codes both indicate a permanent lockout caused by a problem with the flue gas temperature sensor (an NTC thermistor). Specifically, the boiler's PCB has detected that this sensor has short-circuited, is not connected at all, or has a poor connection that is producing unreliable readings. Because the PCB continuously monitors the resistance signal from this thermistor to track flue gas temperature, a short-circuit causes wildly incorrect data to reach the control board — and as a safety precaution, the boiler shuts down completely and will not restart until the fault is resolved and a manual reset is performed. These are classed as permanent faults, meaning a reset alone will not clear them without the underlying issue being fixed first. Two related sub-codes worth knowing: E.04-.06 triggers when a critically high flue gas temperature is actually reached (often alongside a circulation or sensor fault), and E.04-.08 indicates the boiler has hit its maximum safe temperature limit, which can also involve the safety thermostat opening or a circulation failure.