Glow-worm F71
The F71 code appears on Glow-Worm boilers when the control board detects a problem with one or both of the water temperature sensors — specifically the flow sensor (which monitors water leaving the boiler) or the return sensor (which monitors cooler water coming back from the heating circuit). These sensors are NTC thermistors: small resistive components whose electrical resistance changes as temperature rises or falls, giving the PCB a continuous read-out of water temperature. When the PCB receives a reading that is implausible, out of range, or missing entirely, it triggers F71 and shuts the boiler down as a precaution. The fault can point to a wiring or connector issue, a failed thermistor, a circulation problem, or — less commonly — a defective internal expansion vessel or PCB fault affecting how sensor signals are interpreted.
Causes, fixes & costs for Glow-worm F71 → · All Glow-worm codes