Glow-worm F84
The F84 code appears when the boiler's control board detects a persistent, irreconcilable difference between the readings from the heating flow NTC thermistor and the heating return NTC thermistor. Under normal operation, these two sensors work in tandem — the flow thermistor monitors water leaving the heat exchanger, while the return thermistor reads the cooler water coming back from the radiators. When the gap between their readings is permanently outside acceptable limits, the boiler concludes something is wrong with the sensing arrangement itself and locks out to prevent unsafe operation. This typically points to a faulty, swapped, or disconnected thermistor, damaged wiring between the sensors and the PCB, or — less commonly — a circulation problem that is preventing normal heat distribution around the system.