Baxi H.01-.08
The H.01–.08 code is a temporary self-protection status on Baxi boilers, meaning the boiler has detected that the flow temperature in heating mode is climbing faster than expected. Rather than locking out completely, the boiler pauses operation for roughly 10 minutes to let things settle, then attempts to restart automatically. It points to either insufficient or absent water circulation through the primary circuit, or a flow temperature sensor that is misreading. It is worth knowing where this sits within the wider H.01 family: H.01–.05 triggers when the difference between flow and return temperatures exceeds the permitted maximum, H.01–.08 (this code) fires when the flow temperature itself rises too rapidly in heating mode, and H.01–.18 indicates a temporary loss of circulation. All three share the same root causes but the boiler's internal logic distinguishes them by which threshold has been crossed.