Baxi H.01-.14
H-codes on Baxi boilers are 'blocking' faults rather than permanent lockouts. The boiler pauses to protect itself but may restart automatically once conditions return to normal, without needing a manual reset. H.01–.14 specifically tells you that the water temperature at the flow sensor has climbed beyond the permitted maximum, most likely because water is not circulating properly around the heating system. Several sub-codes sit within this family and each points to a slightly different aspect of the same underlying problem: H.01.05 means the temperature difference between the flow and return pipes has become too large, suggesting sluggish or blocked circulation; H.01.08 means the flow temperature in heating mode is rising faster than it should, causing the boiler to pause for roughly ten minutes before attempting to restart; H.01.14 (the broadest of the group) confirms the overall maximum flow temperature threshold has been breached. All of these sub-codes share the same root causes and the same diagnostic approach.