Daikin H1-00 Fault Code: Causes, Fixes & Repair Costs

What does the Daikin H1-00 fault code mean?

The H1-00 code on Daikin Altherma heat pumps indicates a problem with the optional indoor ambient temperature sensor (thermistor R6T) or, on some models, a communication breakdown between the indoor and outdoor units. The system has detected that the sensor reading is outside its expected operating range — returning an implausible value or no signal at all. On most Altherma Monobloc models the heat pump will continue running in a limited capacity, but the fault should be investigated promptly to avoid incorrect operation or further component damage.

Engineer may be needed 4 models affected

General guidance only — not a substitute for professional advice, and not certified by an heat pump engineer. Always have your specific appliance assessed by a qualified professional. Any heat pump work must be carried out by an MCS-certified heat pump engineer. If you notice a refrigerant leak, a burning smell or water leaking from the unit, switch it off at the isolator and call an MCS-certified heat pump engineer. Refrigerant work must be carried out by an F-Gas registered engineer.

Common causes

How to fix it

  1. Check whether the unit is still in warranty DIY safe

    Daikin typically offers a 5-year warranty on Altherma heat pumps when registered. If your system is under 5 years old, contact your installer or Daikin UK before spending anything — parts and labour may be fully covered. Keep your installation paperwork to hand.

  2. Perform a controlled power reset DIY safe

    Switch off the heat pump at the indoor controller, then turn off the dedicated isolator or circuit breaker for both the indoor and outdoor units. Leave everything off for at least 10 minutes to allow the PCB capacitors to fully discharge. Restore power and check whether H1-00 reappears. A one-off power event can cause a transient fault that clears cleanly this way. If the code returns within a short time, a reset alone will not resolve the underlying issue.

  3. Check the outdoor unit for obstructions DIY safe

    While the unit is resetting, go outside and check that the outdoor unit's air intake and discharge are free from leaves, debris, or compacted snow and ice. Poor airflow can cause sensor readings to behave unexpectedly. Clear any blockages by hand — do not use sharp tools or a pressure washer near the unit.

  4. Verify system water pressure DIY safe

    Check the system pressure gauge on the indoor unit. Daikin Altherma systems typically operate between 1.0 and 2.5 bar when cold. If pressure is low, top up via the filling loop following the guidance in your user manual. Low pressure is not a direct cause of H1-00 but rules out a simultaneous secondary problem.

  5. Inspect the sensor connector and wiring — engineer task heat pump engineer

    An MCS-certified engineer should visually inspect the wiring loom and connector at thermistor R6T and at the hydro PCB A1P for signs of corrosion, chafing, or loose pins. A multimeter resistance check of R6T against Daikin's published temperature-resistance table will confirm whether the sensor is within specification or has failed.

  6. Test and replace thermistor R6T if required — engineer task heat pump engineer

    If resistance readings are outside specification, the engineer should replace thermistor R6T with the correct Daikin-approved part for the model. After fitting, they should clear the fault code and confirm the sensor reads a plausible ambient temperature before returning the system to normal operation.

  7. Inspect the hydro PCB A1P and noise filter PCB — engineer task heat pump engineer

    If the thermistor and wiring are both healthy, the engineer should check that the hydro PCB A1P is receiving the correct supply voltage and inspect the noise filter PCB for signs of burn marks, swollen capacitors, or physical damage. PCB replacement should only be carried out by a qualified engineer using manufacturer-approved components.

  8. Verify the incoming power supply quality — engineer task heat pump engineer

    The engineer should confirm that the mains supply voltage and phase balance meet Daikin's specifications (typically within 4 % imbalance for three-phase supplies). If supply quality is poor, an electrician should investigate upstream before the heat pump is returned to service.

  9. Contact an MCS-certified heat pump engineer if the fault persists heat pump engineer

    If H1-00 returns after a reset and the above homeowner checks have been completed, book a visit from an MCS-certified heat pump engineer experienced with Daikin Altherma systems. Any work involving refrigerant circuit components also requires an F-Gas registered engineer. You can find qualified engineers via the MCS installer database at mcscertified.com.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£450, depending on the underlying cause.

Frequently asked questions

Can I keep using my heat pump while H1-00 is showing?

On most Daikin Altherma Monobloc models the system continues to operate when H1-00 is active, because R6T is an optional rather than a critical sensor. However, running with a faulty ambient sensor means the heat pump may not be optimising its output correctly, which can reduce efficiency and increase running costs. It is worth getting the fault diagnosed within a few days rather than ignoring it indefinitely.

H1-00 appeared after a power cut — do I need an engineer?

Not necessarily straight away. A power surge or brief outage can occasionally latch a fault code without any hardware actually failing. Perform the controlled power reset described above (switch off the isolator, wait 10 minutes, restore power). If H1-00 does not return within a normal heating cycle, the issue was almost certainly a transient power event. If the code comes back, call an engineer.

How much does it typically cost to fix H1-00 on a Daikin Altherma?

Most people with this fault pay somewhere between £150 and £450 all in. A wiring or connector repair sits at the lower end (around £150–£200 including the callout), while a thermistor replacement typically comes to £200–£350 including parts and labour. A hydro PCB replacement is the more expensive scenario, usually £400–£600 once parts and labour are combined — and in rare cases where a main PCB or additional components are needed, costs can climb higher still. Always ask for a written quote before work begins.

Is H1-00 covered under my Daikin warranty?

Daikin Altherma heat pumps typically carry a 5-year warranty when properly registered after installation. If your unit is within that period and the fault is due to a manufacturing defect rather than physical damage or incorrect installation, the repair should be covered at no cost. Contact your original MCS-certified installer in the first instance — they are responsible for warranty claims with Daikin. If you are unsure who installed your system, Daikin UK customer support can advise.

Affected models: Daikin Altherma 3 M (ASHP), Daikin Altherma Monobloc (e.g. EDLQ05CAV3), Daikin Altherma HT, Selected older Daikin split and chiller units

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a heat pump engineer

✓ Your boiler details: Daikin H1-00 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →