Daikin PJ-00 Fault Code: Causes, Fixes & Repair Costs

What does the Daikin PJ-00 fault code mean?

The PJ-00 fault code flags a configuration or hardware problem with the outdoor unit's main PCB. Specifically, it points to one of two closely related issues: either the capacity setting adaptor (a small plug-in resistor that tells the board what size unit it's controlling) is absent or incorrect, or there is a mismatch between the inverter board and the fan driver board installed in the outdoor unit. Either way, the outdoor unit cannot verify its own identity or configuration, so it locks out to prevent damage. This code sits within the 'P' family of outdoor unit errors and the sub-code '00' identifies the master outdoor unit as the source.

Lockout — engineer likely 4 models affected

General guidance only — not a substitute for professional advice, and not certified by an heat pump engineer. Always have your specific appliance assessed by a qualified professional. Any heat pump work must be carried out by an MCS-certified heat pump engineer. If you notice a refrigerant leak, a burning smell or water leaking from the unit, switch it off at the isolator and call an MCS-certified heat pump engineer. Refrigerant work must be carried out by an F-Gas registered engineer.

Common causes

How to fix it

  1. Note the exact fault code displayed and perform a single power-cycle reset DIY safe

    Before touching anything, take a photo of the fault code on the controller display. Switch the heat pump off at the indoor controller, wait 30 seconds, then switch it back on. If PJ-00 clears and does not return, monitor the unit closely over the next few hours. If the fault reappears after just one reset, do not keep cycling the power — repeated resets will not resolve a configuration fault and may mask the issue for an engineer.

  2. Check the outdoor unit for obvious physical issues DIY safe

    Walk around the outdoor unit and look for signs of water pooling inside the casing, storm damage, or debris blocking the cabinet. Do not open the electrical enclosure or touch any internal components. If you can see that a connector has physically come away from a board through the vents, report this to your engineer but do not attempt to reconnect it yourself.

  3. Check whether a PCB or any component was recently replaced DIY safe

    If your system has had any recent service work — particularly a main PCB replacement — this is almost certainly the cause. Contact the engineer who did the work and tell them PJ-00 has appeared; the likely culprit is a missing or incorrect capacity setting adaptor, which is a straightforward and inexpensive fix when caught early.

  4. Have an engineer verify and fit the correct capacity setting adaptor heat pump engineer

    An MCS-certified engineer will open the outdoor unit electrical enclosure, identify the main PCB, and check whether the capacity setting adaptor (a small resistor plug specific to the unit's rated output) is present and matched to the unit. If it is missing or wrong, fitting the correct one is a quick and low-cost fix. The part itself costs only a few pounds, though you will still pay the engineer's callout and labour time.

  5. Have the engineer confirm PCB compatibility and board identity heat pump engineer

    If the adaptor is correct, the engineer should cross-reference the part numbers on all installed boards (control PCB, inverter PCB, fan driver PCB) against the unit's model number. A board sourced from the wrong series will need to be returned and the correct one ordered. Daikin UK's parts warehouse in Weybridge stocks common boards and can often deliver next working day.

  6. Have the engineer apply the correct field settings heat pump engineer

    After any PCB replacement, Daikin requires specific field settings to be programmed through the service interface. The engineer should work through the field setting checklist in the unit's service manual to confirm all parameters — including capacity, connected indoor units, and sensor assignments — are correctly configured.

  7. Have the engineer inspect for electrical damage and test the board heat pump engineer

    If no configuration error is found, the engineer should inspect the PCB for signs of surge damage (scorching, swollen capacitors), moisture ingress, or corroded connectors. Wiring continuity and fuse integrity should also be checked. If the board is confirmed faulty and is not repairable, it will need to be replaced with the correct matched board and adaptor.

  8. If the fault persists, contact an MCS-certified heat pump engineer for a full diagnostic heat pump engineer

    PJ-00 always requires an engineer to resolve correctly — there is no homeowner fix for a PCB configuration or hardware fault. Ensure your engineer is MCS-certified and, if refrigerant circuit work becomes necessary during the repair process, F-Gas registered. If the unit is still within Daikin's warranty period (typically 5–7 years via a certified installer), log the fault with Daikin UK before authorising any paid repair work.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £280–£750, depending on the underlying cause.

Frequently asked questions

Can I fix the Daikin PJ-00 fault myself?

No — PJ-00 is a PCB configuration or hardware fault inside the outdoor unit's electrical enclosure, which is not safe or appropriate for a homeowner to open. The only DIY steps are noting the fault code, trying a single reset, and checking the outside of the unit for obvious damage. Everything else requires an MCS-certified engineer.

Is PJ-00 always caused by a failed PCB, or could it be something cheaper?

Quite often it is something cheaper. If a PCB has been replaced recently, the most likely cause is simply a missing or incorrectly rated capacity setting adaptor — a part that costs around £5–£10. You still pay for the engineer's callout and time, but the repair itself is straightforward. Only if the adaptor is correct and the boards are properly matched should a full PCB replacement be considered. For reference, a new outdoor unit PCB with labour typically costs £400–£750; a board refurbishment service can be £150–£400. For rare cases involving multiple failed boards or severely water-damaged units, costs can exceed these figures.

My heat pump is still under warranty — does Daikin cover PJ-00?

Potentially yes. Daikin offers 5–7 year parts and labour warranties through MCS-certified installers. Log the fault with Daikin UK before authorising any paid repair work, as an unauthorised repair could affect your warranty. If the fault has appeared after a recent service by your installer — for example because a PCB was swapped without fitting the correct adaptor — that installer may be liable for the cost of putting it right.

Will PJ-00 damage my heat pump if I leave it running?

The unit has locked itself out specifically to prevent damage, so it will not run normally while PJ-00 is active. Do not attempt to repeatedly reset the unit to force it to run — this will not resolve a configuration fault and may cause additional wear on components that try to start without valid configuration data. Book an engineer promptly, particularly in cold weather when losing your heating and hot water has an immediate impact.

Affected models: Daikin Altherma (residential air-source heat pump range), Daikin SkyAir, Daikin VRV (multi-unit / commercial), Daikin ducted outdoor units (various series)

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a heat pump engineer

✓ Your boiler details: Daikin PJ-00 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →