Ferroli A07 Fault Code: Causes, Fixes & Repair Costs

What does the Ferroli A07 fault code mean?

The A07 code appears when the flue gas probe detects an excessively high temperature — typically sustained for more than around two minutes — and the boiler shuts itself down as a safety precaution. Because it begins with 'A', this is a lockout fault on Ferroli boilers, meaning the boiler will not restart on its own and needs a manual reset once the underlying problem has been addressed. You may also encounter the related codes F07 and F14 on some Ferroli models: F-prefix codes are 'blocking' faults that can clear automatically when the triggering condition resolves, whereas A07 always requires deliberate intervention. In all cases the root concern is the same — the flue gas pathway or the heat exchanger is running hotter than it should be, and the boiler is protecting itself from damage or a potentially unsafe condition.

Lockout — engineer likely Some DIY checks possible May need a Gas Safe engineer 6 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Inspect the external flue terminal for visible blockages DIY safe

    Go outside and look at the point where the flue exits the building. Check for bird nests, compacted debris, ice, or any physical obstruction covering the outlet. Do not attempt to access the roof unsafely; if the terminal is at height and you cannot see it clearly from ground level, leave this check to an engineer.

  2. Check whether the condensate pipe is frozen DIY safe

    During cold weather, locate the condensate pipe — usually a white or grey plastic pipe (typically 21.5 mm or 32 mm diameter) that exits the boiler and runs to an external drain or soakaway. If it feels solid or you can see ice, gently warm the frozen section using warm (not boiling) water or a heat pad. Never use a naked flame.

  3. Reset the boiler once the external checks are complete DIY safe

    Switch the boiler off at its power switch and leave it for around 10–15 seconds to allow the internal electronics to settle. Then press and hold the reset button while switching the boiler back on. Keep the reset button pressed until the display changes or the boiler completes its startup sequence, then release it. If the A07 returns within a short period, do not keep resetting — repeated forced restarts when a mechanical fault is present can cause costly damage to the heat exchanger or fan.

  4. Do not reset the boiler more than two or three times DIY safe

    If the fault code reappears after two or three resets, there is a genuine internal problem. Stop attempting resets and arrange for a Gas Safe engineer to investigate. Each unnecessary restart risks overheating and damaging components.

  5. Have a Gas Safe engineer inspect the fan and air pressure switch Gas Safe engineer

    An engineer will test fan speed and output, check the pressure switch sensing tube for blockages or cracks, and verify that the switch is opening and closing at the correct differential pressure. A faulty fan or switch will be replaced with the correct Ferroli part.

  6. Have the flue gas probe tested and replaced if necessary Gas Safe engineer

    The engineer will measure the probe's electrical resistance and compare it against the manufacturer's specification across a range of temperatures. A probe that reads outside tolerance, or whose wiring is damaged, will be replaced. This is a straightforward repair on most Ferroli models.

  7. Have the heat exchanger inspected and chemically cleaned or descaled Gas Safe engineer

    If servicing history is poor or the boiler is in a hard-water area, the engineer may flush or chemically descale the heat exchanger. A severely scaled exchanger that cannot be restored may need replacement — a costlier repair that, on older units, can tip the balance towards replacing the boiler altogether.

  8. Call a Gas Safe registered engineer if the fault persists or you are unsure Gas Safe engineer

    If none of the homeowner checks resolve the A07, or if the boiler is locking out repeatedly, contact a Gas Safe registered engineer. You can verify any engineer's registration at gassaferegister.co.uk. Do not attempt to access internal gas components, the PCB, or the fan yourself.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£300, depending on the underlying cause.

Frequently asked questions

What is the difference between Ferroli fault codes A07, F07, and F14?

All three relate to abnormal flue gas temperature conditions, but they behave differently. A07 is a lockout code — the boiler shuts down completely and will only restart after a manual reset. F07 and F14 are blocking codes, meaning the boiler pauses operation but may attempt to restart automatically once the triggering condition clears (for example, if a condensate pipe thaws). If you are seeing F07 or F14 regularly, or they have progressed to A07, treat it as a sign that an underlying fault needs professional attention rather than relying on automatic recovery.

Can I reset a Ferroli A07 fault myself?

Yes, a single reset attempt is a reasonable first step once you have checked the flue terminal and ruled out a frozen condensate pipe. Switch the boiler off, wait about 15 seconds, then press and hold the reset button while turning it back on. However, if the code returns after two or three resets, stop and call a Gas Safe engineer. Repeatedly forcing the boiler to fire when a mechanical fault is present — particularly a fan or heat exchanger problem — risks causing serious and expensive damage.

How much does it typically cost to fix a Ferroli A07 fault in the UK?

Most A07 repairs fall in the region of £100–£300 all-in. A flue gas sensor replacement is usually at the lower end (roughly £80–£130 including labour), while a fan replacement typically costs £180–£250. A Gas Safe engineer's initial diagnosis visit alone generally costs £80–£150. If the heat exchanger is severely scaled and needs replacement, costs can rise considerably higher — potentially £400–£600 or more — and on a Ferroli that is over 10 years old it is worth comparing that against the cost of a new boiler.

Why does my Ferroli keep showing A07 even after a reset?

A recurring A07 almost always points to a persistent mechanical or sensor problem rather than a one-off glitch. The most common culprits are a fan that is losing efficiency, a heat exchanger that is heavily scaled and retaining too much heat, or a flue gas probe that has drifted out of calibration. Less often, a partially blocked flue terminal or a faulty air pressure switch is the cause. Each time you reset without fixing the root cause, you risk further damage, so arrange a professional inspection if the fault keeps coming back.

Affected models: Ferroli Modena, Ferroli Bluehelix, Ferroli Optimax, Ferroli i-Series, Ferroli Domiproject, Ferroli Divatech

Last reviewed 8 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Ferroli A07 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →