Intergas 14 Fault Code: Causes, Fixes & Repair Costs

What does the Intergas 14 fault code mean?

Fault code 14 on Intergas boilers indicates that the boiler's PCB has detected a problem with the readings coming from the S1 temperature sensor. The S1 sensor sits on the heat exchanger and monitors the temperature of water leaving it — the flow temperature. When those readings fall outside the boiler's acceptable tolerance range, the boiler locks out and displays code 14 to protect itself from operating in an unsafe or inefficient condition. The root cause could be the sensor itself, a problem with the heat exchanger it monitors, or a PCB that is misreading or not receiving the sensor signal at all.

Lockout — engineer likely May need a Gas Safe engineer 4 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Do not repeatedly reset the boiler DIY safe

    Unlike some fault codes where a reset is a reasonable first step, resetting the boiler is not designed to clear an underlying fault code 14. The reset function is intended to be used after the fault has been identified and repaired. Repeatedly resetting a locked-out boiler without addressing the cause risks masking the problem and could cause further damage.

  2. Check your gas supply is working DIY safe

    Before calling an engineer, quickly confirm that other gas appliances in your home (such as your hob or oven) are working normally. If they are not, the issue may be with your gas supply rather than the boiler — contact your gas supplier. If only the boiler is affected, proceed with arranging an engineer visit.

  3. Engineer to test and replace the S1 sensor if required Gas Safe engineer

    A Gas Safe registered engineer will measure the resistance of the S1 sensor against the manufacturer's specification. If the reading is outside tolerance, the sensor should be replaced with a genuine Intergas part. Using non-original sensors can cause further faults or void your warranty. After fitting a new sensor the engineer will reset the boiler and monitor its operation.

  4. Engineer to inspect and service the heat exchanger Gas Safe engineer

    If a new S1 sensor does not clear the fault, the engineer will inspect the heat exchanger for limescale build-up or physical damage. Light to moderate limescale may be addressed with a descale treatment or a full system power flush. A cracked heat exchanger will need to be replaced promptly — water leaking from a crack can quickly damage surrounding electrical components.

  5. Engineer to test the PCB Gas Safe engineer

    If the sensor and heat exchanger are both found to be in acceptable condition, the engineer will use a multimeter to test the PCB for correct power delivery and signal processing. A faulty PCB will need to be replaced. Given the cost of a new PCB, it is worth asking your engineer to discuss whether repair or full boiler replacement makes better financial sense, especially on older units.

  6. Call a Gas Safe registered engineer Gas Safe engineer

    Fault code 14 requires diagnosis and repair by a qualified Gas Safe registered engineer. Do not attempt to access internal boiler components yourself. When booking, mention the specific fault code so the engineer can arrive prepared with the most likely replacement parts, such as an S1 sensor, reducing the number of visits needed.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£350, depending on the underlying cause.

Frequently asked questions

Can I reset my Intergas boiler to fix fault code 14?

Resetting the boiler will not fix the underlying problem causing code 14. On Intergas boilers the reset function is intended to restart the boiler after a fault has been properly diagnosed and repaired — not as a troubleshooting step in itself. If you reset the boiler and it fires up temporarily before locking out again, the root cause is still present. Call a Gas Safe engineer rather than continuing to reset.

How much does it cost to repair Intergas fault code 14 in the UK?

For the most common repair — replacing the S1 sensor — you can typically expect to pay around £120–£200 including an engineer call-out and the part. If the heat exchanger needs descaling or a power flush the cost usually falls in the £150–£350 range. A full heat exchanger replacement tends to cost around £400 and a PCB replacement is typically in the £400–£500 bracket. If your boiler is older or out of warranty and facing a major component failure, it is worth getting a new boiler quote at the same time, as a full replacement typically costs between £1,500 and £3,000 installed.

What is the S1 sensor on an Intergas boiler and why does it matter?

The S1 sensor is a temperature probe mounted on the heat exchanger that continuously measures the temperature of water flowing out of it. It feeds this data to the PCB, which uses it to control burner operation and keep the boiler running safely. When S1 readings are absent or outside the expected range, the PCB locks the boiler out to prevent overheating or unsafe operation. It is important that only genuine Intergas S1 sensors are used as replacements — non-original parts can cause ongoing faults or invalidate your warranty.

How can I prevent fault code 14 from coming back?

The two most effective preventive measures are having the boiler serviced annually (which also keeps your Intergas warranty valid) and fitting a magnetic system filter if one is not already installed — this catches metallic sludge that can affect sensors and heat exchangers. If you live in a hard water area (most of southern England), fitting a scale reducer and adding a suitable inhibitor to the system water significantly reduces limescale build-up on the heat exchanger, which is the second most common trigger for this fault code.

Affected models: Intergas Combi Compact, Intergas HRE, Intergas Xtreme, Intergas Rapid

Last reviewed 8 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Intergas 14 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →