Intergas F004 Fault Code: Causes, Fixes & Repair Costs

What does the Intergas F004 fault code mean?

The F004 code appears on Intergas boilers when the PCB (the boiler's control board) cannot detect a valid flame signal from the burner. This can mean one of two things: the burner is attempting to ignite but the flame sensor isn't picking up the flame, or the boiler is failing to ignite at all. Either way, the boiler locks out as a precaution to prevent unsafe operation. When the fault triggers, the service symbol flashes and F004 is shown on the left-hand display for around 30 seconds before the boiler shuts down.

Lockout — engineer likely May need a Gas Safe engineer 4 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check that your gas supply is active DIY safe

    Confirm that other gas appliances in the property (hob, gas fire, etc.) are working normally. Also check that the isolation valve on the pipe leading into the boiler is in the open position — the handle should be parallel to the pipe. If you have a prepayment meter, ensure it has sufficient credit.

  2. Reset the boiler DIY safe

    Press and hold the flashing Service button on the boiler's control panel for approximately two seconds to reset. The boiler will attempt to re-ignite. If it fires up and runs normally, monitor it over the next 24 hours. If F004 returns, do not keep resetting repeatedly — two or three attempts is the limit before you need professional help.

  3. Do not attempt to inspect or replace internal components yourself Gas Safe engineer

    The flame sensor, gas valve, ignition electrode, and connecting leads are all internal boiler components. Inspecting, cleaning, or replacing any of these requires the boiler to be stripped down and involves gas pipework. This work must only be carried out by a Gas Safe registered engineer — it is illegal and dangerous for an unqualified person to do so.

  4. Contact a Gas Safe registered engineer to diagnose and repair the fault Gas Safe engineer

    An engineer will remove and inspect the flame sensor first, as it is the most common culprit — cleaning or replacing it is a relatively straightforward job. If the sensor is not at fault, they will test the gas valve electrically and mechanically, check ignition lead continuity and condition, and inspect the burner for carbon fouling. They will carry out any necessary repairs or component replacements safely and legally.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £80–£350, depending on the underlying cause.

Frequently asked questions

Can I reset an Intergas F004 fault myself?

Yes, a reset is the one thing you can safely try yourself. Hold the Service button for about two seconds to clear the lockout and allow the boiler to attempt re-ignition. If F004 comes back after one or two resets, stop trying — repeated failed ignition attempts can cause unburnt gas to accumulate, and the underlying fault needs a Gas Safe engineer to diagnose properly.

How much does it cost to fix an Intergas F004 fault in the UK?

Most people pay somewhere between £80 and £350 depending on what's wrong. If the flame sensor simply needs cleaning or replacing, you're likely looking at the lower end — often covered within a standard call-out and labour charge. A gas valve replacement typically costs around £250–£350 including parts and labour, and may take a day or two if the part needs to be ordered. In rare cases where the PCB is at fault, costs can rise to £400–£500 or more, though this is uncommon with F004 specifically.

Why does my Intergas boiler keep showing F004 after I reset it?

If F004 returns quickly after each reset, the boiler is failing to establish or hold a flame every time it tries to light. This points to a persistent component fault rather than a one-off glitch — most likely a degraded flame sensor, a gas valve that isn't opening correctly, or a wiring issue. Each failed attempt is the boiler correctly protecting itself, so repeated resetting won't fix the underlying problem. You need a Gas Safe engineer to investigate.

Is F004 dangerous — should I stop using the boiler?

Intergas boilers lock out when F004 is triggered, so the boiler has already shut itself down as a precaution. While the lockout itself means the boiler is in a safe state, you should not attempt to bypass it or override the safety shutdown. Arrange for a Gas Safe engineer to inspect the boiler before returning it to normal use. If you smell gas at any point, do not reset the boiler — leave the property, open windows, and call the National Gas Emergency Service on 0800 111 999.

Affected models: Intergas Xtreme, Intergas Kombi Kompakt, Intergas HRE, Intergas Rapid

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Intergas F004 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →