Johnson & Starley 13 Fault Code: Causes, Fixes & Repair Costs

What does the Johnson & Starley 13 fault code mean?

Fault code 13 (shown as E13 on the display) is a safety lockout that appears across several Johnson & Starley ranges — including the Quantec, Reno, WarmCair, and Economaire. Depending on your specific model, it signals one of two related problems: either the boiler's flue gases have exceeded a safe temperature threshold and the appliance has shut itself down to prevent damage, or the control system has detected a flame sensing or gas pressure failure during operation. In both cases the boiler locks out until the underlying fault is identified and resolved. Because fault code numbering is not consistent across all Johnson & Starley product ranges, you should cross-reference with your own model's manual or contact Johnson & Starley directly on 01604 762881 to confirm the exact meaning for your appliance.

Lockout — engineer likely May need a Gas Safe engineer 4 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check your gas supply is on DIY safe

    Make sure the gas isolation valve on the supply pipe to the boiler is fully open and that other gas appliances in the property (such as a hob or gas fire) are working normally. If no gas appliances are working, contact your gas supplier rather than an engineer.

  2. Reset the boiler — no more than twice DIY safe

    Press and hold the reset button as described in your user manual. If E13 clears and the boiler fires up normally, monitor it over the next hour. If the fault returns after one or two resets, stop resetting — repeated lockouts indicate an underlying fault that needs professional diagnosis.

  3. Inspect the flue terminal for obvious blockages DIY safe

    Go outside and visually check the flue outlet. Look for visible obstructions such as debris, ice, or a bird's nest near the terminal. Do not attempt to clear internal flue blockages yourself. If the terminal looks clear, report your findings to the engineer.

  4. Check system pressure (if a sealed system boiler) DIY safe

    Glance at the pressure gauge on the boiler. It should read between 1.0 and 1.5 bar when cold. If it is below 0.8 bar, top it up via the filling loop following your user manual instructions. Low pressure alone is unlikely to cause E13 but is worth correcting before the engineer visits.

  5. Have a Gas Safe engineer inspect the flame sensor and sensing lead Gas Safe engineer

    An engineer will remove and clean or replace the ionisation probe and check the entire flame detection lead from the probe to the control board for damage, loose connections, or a short to earth. This is the most common fix for E13 on the Quantec and Reno ranges.

  6. Have the fan tested and flue system inspected Gas Safe engineer

    The engineer will check that the combustion fan reaches its correct operating speed and that the flue system is clear, undamaged, and free from restrictions. A faulty fan will need to be replaced; a blocked flue will be cleared or the terminal replaced.

  7. Have gas supply pressure verified at the boiler Gas Safe engineer

    Using a manometer, the engineer will confirm that gas pressure at the boiler inlet is within the manufacturer's specified range both at rest and under load. If pressure drops during firing, the fault may lie with the meter regulator or gas valve, which will need further investigation.

  8. Have the limit switch continuity and heat exchanger condition checked Gas Safe engineer

    The engineer will test the overheat limit switch for correct continuity and inspect the heat exchanger for scaling, sludge build-up, or physical damage. A failed limit switch can be replaced; a severely scaled or cracked heat exchanger may require replacement.

  9. Have the PCB assessed if all other components test satisfactory Gas Safe engineer

    If every other component checks out, the engineer may suspect the PCB is misinterpreting sensor signals. PCB diagnosis and replacement must be carried out by a qualified engineer using manufacturer-compatible parts.

  10. Call a Gas Safe registered engineer if you have not already done so Gas Safe engineer

    E13 is a safety lockout involving gas combustion components. If the boiler has not cleared after one or two resets, book a Gas Safe registered engineer as soon as possible. You can find one at the Gas Safe Register website (gassaferegister.co.uk). Always ask to see their Gas Safe ID card before work begins.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£380, depending on the underlying cause.

Frequently asked questions

Is the E13 fault code the same on all Johnson & Starley boilers?

Not necessarily. Johnson & Starley produce several different product ranges — Quantec, Reno, WarmCair, and Economaire — and the fault code numbering is not universal. On the Quantec and Reno series E13 most commonly relates to flame sensing errors and gas pressure issues, while on other models the same code can indicate a flue or exhaust overtemperature condition. Always check your specific model's manual. If you are unsure, Johnson & Starley's technical line is 01604 762881.

Can I fix Johnson & Starley fault code 13 myself?

There are a couple of quick checks you can safely carry out: confirm the gas supply is on, look for an obvious blockage at the flue terminal outside, and try resetting the boiler once or twice. Beyond that, E13 involves gas combustion components — the flame sensor, gas valve, fan, and potentially the PCB — which must only be worked on by a Gas Safe registered engineer. Attempting to repair these yourself is unsafe and illegal.

How much will it cost to fix E13 on my Johnson & Starley boiler?

Most people pay in the region of £120 to £380 all in, depending on what needs replacing. A flame sensor clean or lead replacement sits at the lower end; a fan replacement typically runs £180–£280 including labour. If the PCB or heat exchanger turns out to be the root cause, costs can be considerably higher — PCBs alone can reach £300–£450 supplied and fitted, and a heat exchanger replacement may exceed that. Getting a fixed-price quote before work starts is always advisable.

Why does my Johnson & Starley boiler keep coming back with fault code 13 after I reset it?

If E13 returns after one or two resets, the underlying fault has not gone away — the boiler is simply locking out again each time it tries to fire and detects the same problem. Repeatedly resetting without fixing the root cause will not resolve it and could mask a developing safety issue. Book a Gas Safe engineer to carry out a proper diagnosis rather than continuing to reset.

Affected models: Quantec, Reno, WarmCair, Economaire

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Johnson & Starley 13 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →