Johnson & Starley 34 Fault Code: Causes, Fixes & Repair Costs

What does the Johnson & Starley 34 fault code mean?

Fault code 34 on a Johnson & Starley warm air unit indicates that the boiler's control electronics have detected an insufficient or unstable incoming mains electrical supply. As a safety precaution, the appliance shuts down rather than continuing to run on degraded power. Once a stable electrical supply is restored, the boiler should be able to resume normal operation — often after a reset. The fault points to something external (your property's electricity supply or the circuit feeding the boiler) or internal (wiring connections within the appliance itself).

Engineer may be needed May need a Gas Safe engineer 1 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check that your property's electricity supply is functioning normally DIY safe

    Confirm other appliances are working and look at your consumer unit for any tripped breakers. If a breaker has tripped, reset it once. If it trips again immediately, do not keep resetting — contact a qualified electrician.

  2. Check the boiler's fused spur or isolator switch DIY safe

    Locate the dedicated fused spur or double-pole isolator switch that supplies power to the boiler (usually on a nearby wall). Make sure it is switched on and that the fuse has not blown. A blown fuse can be replaced like-for-like by a competent person, but if it blows again, stop and call an engineer.

  3. Reset the boiler DIY safe

    If the mains supply appears normal, press the boiler's reset button as described in your user guide. Attempt this no more than two or three times. If fault code 34 returns each time, further DIY action is not appropriate and you should move to the next step.

  4. Arrange for a Gas Safe registered engineer to inspect the boiler's wiring and supply Gas Safe engineer

    A qualified engineer will use a multimeter to measure the actual voltage at the boiler's supply terminals, inspect the wiring from the isolator through to the control board, check all internal connections and the wiring harness, and identify any deterioration or loose terminals that are causing the undervoltage condition.

  5. Engineer to test or replace the control PCB if wiring checks out Gas Safe engineer

    If the mains supply and all wiring are confirmed healthy but code 34 persists, the control board may be misreading the voltage due to an internal fault. On Johnson & Starley warm air units the PCB is supplied as a complete replacement kit. Your engineer will advise whether replacement is cost-effective given the age of the appliance.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£380, depending on the underlying cause.

Frequently asked questions

Can I fix Johnson & Starley fault code 34 myself?

The initial checks — confirming your electricity supply is on, looking for tripped breakers, and pressing the reset button — are safe for a homeowner to carry out. Beyond that, diagnosing and repairing wiring faults or replacing a control board on a warm air unit requires a Gas Safe registered engineer. Attempting electrical work on the boiler yourself risks both safety and invalidating any warranty or service plan.

Will the boiler restart automatically once power is restored?

Johnson & Starley warm air units are designed to return to a safe off-state during a supply failure. Once a stable mains supply is resumed, you will typically need to press the reset button to clear fault code 34 and allow the boiler to restart. If it does not restart normally after one or two resets, the underlying cause has not resolved itself and an engineer's visit is needed.

Could the problem be with my house electrics rather than the boiler itself?

Yes — a failing consumer unit, a deteriorating circuit breaker, or degraded cabling between your consumer unit and the boiler can all cause a persistent undervoltage at the appliance even when the rest of your home's sockets and lights seem fine. In that scenario, a registered electrician would need to inspect the circuit rather than (or in addition to) a Gas Safe engineer checking the boiler's internal wiring.

How much does it cost to replace the PCB on a Johnson & Starley warm air unit if needed?

PCB replacement, including parts and labour, typically falls in the £250–£400 range, though older or less common Johnson & Starley models may have discontinued or hard-to-source boards that push costs higher. The headline repair estimate on this page (£100–£380) reflects the more typical outcome where only wiring repairs or connection work is needed — your engineer should confirm the diagnosis before ordering a PCB.

Affected models: Johnson & Starley warm air units (various models — check the control board cover plate for the full fault code list applicable to your specific unit)

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Johnson & Starley 34 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →