JSJohnson & Starley logo

Johnson & Starley 44 Fault Code: Causes, Fixes & Repair Costs

What does the Johnson & Starley 44 fault code mean?

Code 44 on a Johnson & Starley unit indicates a central-heating return sensor error — the return-side temperature probe has gone open or short circuit. On models that combine warm-air heating with a water circuit (WarmCair D/DW variants providing hot water, and Aquair heat interface units), the controller relies on the CH return probe to manage the water side safely; when its circuit fails in either direction, code 44 appears and normal operation is restricted. Diagnosis is the standard sensor routine: inspect the wiring and connectors, measure the sensor's resistance against the specification table, and replace the failed element.

Engineer may be needed May need a Gas Safe engineer 3 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Reset once and observe DIY safe

    Use the reset control (or switch off at the fused spur for 30 seconds and back on) a single time. If the code returns, stop resetting — Johnson & Starley's warm-air units lock out for a reason, and repetition only masks the fault.

  2. Have a Gas Safe registered engineer complete the documented checks Gas Safe engineer

    The engineer will inspect the CH return sensor's wiring, measure its resistance hot and cold against the table, and replace the sensor or repair the circuit as found, then verify flow/return readings track correctly through a heating cycle.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £90–£240, depending on the underlying cause.

Frequently asked questions

What does code 44 mean?

The central-heating return temperature sensor circuit has failed — open or short. The unit restricts operation because it manages the water circuit by that reading. An engineer confirms sensor versus wiring with a resistance check and replaces the failed part; it is one of the cheaper repairs.

My unit is warm-air only — why a CH code?

Code 44 belongs to the water side, so it appears on the combined models (WarmCair D/DW with hot water, Aquair heat interface units). If a warm-air-only unit shows it, quote the model to the engineer — sensor channel mapping varies across the range.

How much does it cost?

Typically £90–£240 including the visit — the sensor itself is inexpensive. Regional labour rates vary; get a written quote.

Affected models: Johnson & Starley WarmCair D, Johnson & Starley WarmCair DW, Johnson & Starley Aquair HIU

Last reviewed 25 August 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Johnson & Starley 44 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →