Johnson & Starley E02 Fault Code: Causes, Fixes & Repair Costs

What does the Johnson & Starley E02 fault code mean?

E02 on a Johnson & Starley unit is a false flame lockout: the flame-supervision circuit reported a flame at a moment when no flame should exist — typically before ignition or after the gas valve has closed. Controls treat phantom flame signals as seriously as missing ones, because a flame signal with the valve shut suggests either a supervision fault or, worse, gas burning when it should not be. The usual technical causes are benign: a leaking flame signal from a contaminated or damp electrode, condensate tracking across the electrode or its lead, or a fault in the sensing circuit on the board. The unit locks out and must be professionally checked rather than repeatedly reset.

Lockout — engineer likely May need a Gas Safe engineer 4 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Do not keep resetting a false-flame code DIY safe

    One reset is acceptable. E02 concerns flame supervision — the safety chain itself — so recurrence should go straight to an engineer.

  2. Have a Gas Safe registered engineer complete the documented checks Gas Safe engineer

    The engineer will inspect and clean or replace the flame electrode and lead, check for condensate ingress around the sensing path, and test the board's flame-supervision circuit. Because this is the flame-safety chain, they should verify correct flame detection and drop-out times before returning the unit to service.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£300, depending on the underlying cause.

Frequently asked questions

What does E02 mean on my Johnson & Starley?

The controller detected a flame signal when there should be none — a 'false flame'. It is usually a contaminated or damp electrode leaking signal rather than an actual flame, but because it sits in the safety chain the unit locks out and needs an engineer, not repeated resets.

Is a false flame dangerous?

The lockout exists because the condition could indicate gas burning when the valve should be shut. In practice the cause is nearly always electrical leakage on the sensing side — but that distinction is exactly what the engineer verifies. Treat it with respect and, as always, any smell of gas means leave and call 0800 111 999.

What is the usual fix?

Cleaning or replacing the flame electrode and its lead resolves most cases; a board-side supervision fault is the fallback diagnosis. Typical cost £100–£300 depending on which.

Affected models: Johnson & Starley WarmCair CD, Johnson & Starley WarmCair CU, Johnson & Starley WarmCair DW, Johnson & Starley Economaire

Last reviewed 25 August 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Johnson & Starley E02 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →