Keston E41 Fault Code: Causes, Fixes & Repair Costs

What does the Keston E41 fault code mean?

The E41 code indicates that the boiler's fascia (the front control panel) and the main control box (PCB) have lost communication with each other. When this breakdown in the internal data link occurs, the boiler locks out completely and will not attempt to restart on its own — you must press the Reset button to try to clear it. Note that error code E99 on Keston boilers points to the same underlying fault and should be diagnosed in exactly the same way as E41.

Lockout — engineer likely May need a Gas Safe engineer 6 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Reset the boiler using the built-in reset button DIY safe

    Press and hold the reset button (often marked with a spanner symbol) for 3–5 seconds until the boiler attempts to restart. A single reset is worth trying — repeat no more than 2–3 times in total. If the E41 code returns each time, a simple reset will not resolve the underlying fault.

  2. Power-cycle the boiler at the mains DIY safe

    Switch the boiler off at the fused spur or isolator switch, wait at least 30 seconds to allow the electronics to fully discharge, then switch it back on. This occasionally clears a transient electronic glitch. If E41 reappears shortly after, move on to the next steps.

  3. Check and reseat the wiring harness between the fascia and control box Gas Safe engineer

    A Gas Safe engineer will remove the boiler casing and inspect the ribbon cable or loom that links the fascia to the main PCB. They will check for loose connectors, bent or corroded pins, chafed insulation, and any visible damage, reseating or replacing the cable as required. This is the most cost-effective repair if it resolves the fault.

  4. Test the electrical circuits for faults Gas Safe engineer

    As part of a thorough electrical check, an engineer should verify mains voltage (230V), correct polarity, earth continuity, and check for any short circuits or excessive resistance to earth in the boiler wiring. Keston's own guidance recommends this as a standard diagnostic step alongside checking the communication cables.

  5. Replace the fascia PCB if wiring checks out Gas Safe engineer

    If all wiring connections are sound but communication is still failing, the fault likely lies within the fascia circuit board itself. An engineer will source a genuine replacement fascia PCB — ideally from Keston (now part of the Ideal group) — fit it, and re-test the communication link.

  6. Replace the main control box PCB if the fascia is confirmed functional Gas Safe engineer

    Should both the wiring and the fascia board test satisfactorily, the main control box PCB is the likely culprit. The engineer will obtain the correct board for the specific Keston model, replace it, reinstate any stored parameters, and carry out a full commissioning check before returning the boiler to service.

  7. Contact a Gas Safe registered engineer with Keston experience Gas Safe engineer

    Keston boilers use a twin-flue design and a modulating pump, making them more complex than many standard combi boilers. Not all heating engineers are familiar with them. When booking, ask specifically whether the engineer has worked on Keston appliances before. You can also contact Keston's technical helpline via keston.co.uk — they can recommend local engineers who know the range well.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£450, depending on the underlying cause.

Frequently asked questions

What is the difference between Keston E41 and E99?

On Keston boilers, E99 is treated as identical to E41 — both point to a communication breakdown between the fascia panel and the main control box. If your display shows E99, follow exactly the same diagnostic and repair steps as for E41. There is no separate fault procedure for E99.

Can I fix a Keston E41 fault myself?

There are two safe steps a homeowner can try: resetting the boiler (up to 2–3 times) and power-cycling it at the mains for 30 seconds. If either clears the fault, great — keep an eye on it. However, everything beyond that — opening the casing, inspecting wiring, and replacing PCBs — must be carried out by a Gas Safe registered engineer. Keston boilers are particularly complex due to their twin-flue design, so always ask whether an engineer has specific Keston experience before booking.

How much does it cost to fix a Keston E41 fault in the UK?

If the problem is simply a loose or damaged cable, you might pay £120–£200 all-in for the call-out, diagnosis, and a wiring repair. If the fascia PCB needs replacing, expect £300–£450 including parts and labour. A main control box PCB replacement is the most expensive common repair, typically £450–£700 including a genuine Keston board and engineer time. If your boiler is more than 12–15 years old and needs a PCB alongside other worn components, it may be worth comparing the repair cost against a new boiler installation.

Why is my Keston boiler showing E41 after a power cut?

A sudden loss of mains power can occasionally scramble the stored settings or disrupt the communication handshake between the fascia and the main control board, triggering E41 when the boiler restores power. Try power-cycling the boiler — switch it off at the mains for 30 seconds, then back on — and then press the reset button. If the code clears and does not return, the power cut was likely the cause. If E41 comes back within a day or two, there is an underlying hardware fault that needs a Gas Safe engineer to investigate.

Affected models: Keston C36 Combi, Keston C36S, Keston Heat 45, Keston Heat 60, Keston System 36, Keston System 60

Last reviewed 2 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Keston E41 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →