Navien E594 Fault Code: Causes, Fixes & Repair Costs

What does the Navien E594 fault code mean?

The E594 code on a Navien boiler signals either a partial PCB communication breakdown or an EEPROM fault. Put simply, the main control board is struggling to communicate correctly with one or more connected components, or the small memory chip on the board (the EEPROM, which stores configuration data) has developed a problem. Navien uses sub-codes alongside E594 to narrow down exactly where the fault lies — always note the sub-code number shown on your display, as it tells you which component is at fault: Sub-code 0 = high-limit switch of the heat exchanger (check PCB); Sub-code 1 = exhaust sensor wiring or sensor itself; Sub-code 2 = flame rod connection or flame sensor; Sub-codes 3–14 = PCB fault (check the PCB); Sub-code 15 = pressure sensor reading below expected range (check wiring and output voltage); Sub-code 16 = pressure sensor reading above expected range (check wiring and output voltage). Sharing your sub-code with an engineer before they arrive will save diagnostic time and potentially reduce the call-out cost.

Stop & check now May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Note the sub-code displayed alongside E594 DIY safe

    Before doing anything else, write down the full code as shown on the boiler display — for example 'E594-1' or 'E594-15'. This sub-code tells you (and any engineer you call) exactly which component the PCB is flagging, cutting down diagnostic time significantly.

  2. Attempt a power reset DIY safe

    Switch the boiler off at the power switch or unplug it from the mains socket. Wait a full 30 seconds to allow the internal electronics to fully discharge, then restore power. A genuine one-off communication glitch will sometimes clear with a reset. If E594 returns immediately or after a short time, do not keep resetting — move on to the next step.

  3. Check for visible moisture or leaks around the boiler DIY safe

    Look carefully underneath and around the boiler casing for drips, damp patches, or water staining. Even a small internal leak can cause PCB damage if left unchecked. If you find any signs of water, turn the boiler off at the mains and do not restart it until an engineer has assessed it.

  4. Check system pressure (if sub-code 15 or 16 is showing) DIY safe

    If your display shows E594-15 or E594-16, glance at the pressure gauge on your boiler. Normal operating pressure for most Navien combi systems is between 1.0 and 1.5 bar when cold. If pressure is very low (below 0.5 bar), you can top it up via the filling loop following your boiler manual. If pressure is normal or high, leave it alone and report the reading to the engineer.

  5. Call a Gas Safe registered engineer to diagnose and repair the fault Gas Safe engineer

    All internal investigation — including inspecting the PCB, testing the exhaust sensor, checking the flame rod, measuring sensor output voltages, and replacing any components — must be carried out by a Gas Safe registered engineer. The engineer will use a multimeter to test voltage and continuity across the PCB, inspect wiring looms and connectors, and determine whether the board needs reconfiguration, repair, or full replacement. Do not open the boiler casing or attempt to disconnect any internal components yourself.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£500, depending on the underlying cause.

Frequently asked questions

What does the sub-code next to E594 mean on my Navien boiler?

Navien displays a sub-code alongside E594 to pinpoint the fault. Sub-code 0 relates to the heat exchanger high-limit switch; sub-code 1 to the exhaust sensor; sub-code 2 to the flame rod; sub-codes 3–14 all point to the PCB itself; sub-code 15 means the pressure sensor is reading below its expected range; and sub-code 16 means it is reading above range. Always tell your engineer which sub-code you see — it can save them 30–60 minutes of diagnostic time.

Can I fix Navien E594 myself?

The only safe DIY steps are noting the sub-code, performing a single power reset, checking for visible leaks, and (for sub-codes 15 or 16) checking the system pressure gauge. Everything beyond that — opening the boiler casing, testing the PCB, replacing sensors or the flame rod — requires a Gas Safe registered engineer. Attempting internal repairs yourself is both dangerous and illegal under UK gas safety regulations.

How much does it cost to fix E594 on a Navien boiler?

For sensor-related sub-codes (exhaust sensor, flame rod, or pressure sensor), repairs typically cost £150–£300 including parts and labour. If the PCB itself needs replacing, expect to pay £300–£500 for most Navien models in 2025, though a minor repair such as reflowing a solder joint may come in closer to £150–£200. In exceptional cases — for example where water damage has also affected surrounding wiring — costs can climb higher. Navien offers manufacturer-backed warranties of up to seven years, so check whether your boiler is still covered before authorising any paid repair.

My Navien PCB was recently replaced and now E594 is showing — why?

This is a recognised issue with newly fitted Navien PCBs. After replacement, the board must be configured and synchronised to the specific boiler model using setup codes. If this step was skipped or done incorrectly, E594 can appear as a memory or configuration fault rather than a hardware failure. Contact the engineer who carried out the replacement — this should be resolved under their warranty of works at no additional charge to you.

Affected models: Navien NCB series, Navien LCB series, Navien NFC series, Navien NPE series, Navien NHB series

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Navien E594 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →