Potterton E09 Fault Code: Causes, Fixes & Repair Costs

What does the Potterton E09 fault code mean?

The E09 fault code on a Potterton boiler indicates that the boiler's control board has detected a problem with the gas valve connection. This could be an intermittent signal, a weak connection, or no signal at all between the PCB and the gas valve. Because the boiler cannot reliably control gas flow to the burner, it treats this as a safety risk and shuts down completely — locking out rather than continuing to run. You will need a Gas Safe registered engineer to diagnose and resolve this fault; there is no safe DIY fix for E09.

Lockout — engineer likely May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Do not repeatedly reset the boiler DIY safe

    Pressing the reset button will not cure E09 — the boiler will lock out again almost immediately each time. Repeated resets do not help and can mask whether the fault is worsening. Limit resets to one attempt at most.

  2. Check that your gas supply is working DIY safe

    Confirm that other gas appliances in your home (such as the hob or gas fire) are working normally. If they are not, contact your gas supplier or the National Gas Emergency Service on 0800 111 999 rather than an engineer.

  3. Ventilate the property if you smell gas DIY safe

    If at any point you detect the smell of gas, do not operate any electrical switches. Open windows and doors, leave the property, and call the National Gas Emergency Service on 0800 111 999 immediately.

  4. Turn off the boiler and call a Gas Safe registered engineer DIY safe

    Because E09 relates directly to the gas valve circuit, all further diagnosis and repair must be carried out by a Gas Safe registered engineer. Switch the boiler off at the programmer or thermostat while you wait.

  5. Engineer to inspect gas valve wiring and connector blocks Gas Safe engineer

    The engineer will systematically check the full wiring loom from the PCB to the gas valve, looking for loose connectors, corroded pins, chafed insulation, and any signs of water damage. Loose connectors are re-seated or replaced; damaged cables are repaired or renewed.

  6. Engineer to test PCB output voltage Gas Safe engineer

    Using a multimeter, the engineer will verify that the PCB is sending the correct voltage signal to the gas valve. If the voltage is absent or incorrect despite intact wiring, the PCB is likely the source of the fault.

  7. Engineer to test or replace the gas valve if required Gas Safe engineer

    If wiring and PCB are confirmed to be working correctly, the engineer will test the gas valve's solenoid coil resistance. A failed coil or mechanically seized valve will require replacement — all gas valve work must be done by a Gas Safe registered professional.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£350, depending on the underlying cause.

Frequently asked questions

Is it safe to keep using my boiler when E09 is showing?

No. E09 causes a full boiler lockout precisely because the boiler cannot safely control the flow of gas. You should leave the boiler switched off until a Gas Safe registered engineer has inspected it. If you smell gas at any point, leave the property and call the National Gas Emergency Service on 0800 111 999.

How much does it cost to fix a Potterton E09 fault?

For the most common repairs — wiring replacement or a gas valve replacement — expect to pay roughly £150–£350 including labour and parts. A straightforward wiring repair at the lower end, and a gas valve swap at the higher end. If the PCB also needs replacing, costs can rise to around £400–£500 depending on the specific board required and the engineer's rates. If your boiler is over 10–12 years old and facing a combined repair bill approaching or exceeding £500, it is worth getting a new boiler quote for comparison.

Can I reset my Potterton boiler to clear E09?

A single reset is worth trying, but E09 is a hard lockout fault and the boiler will almost certainly lock out again immediately. If resetting does not clear the fault, do not keep trying — it will not fix the underlying wiring or valve problem, and could delay getting the right help.

How can I prevent E09 from happening again?

The best preventative measure is an annual boiler service by a Gas Safe registered engineer. During a service, the engineer will check electrical connections, look for early signs of water leaks near wiring, and assess component condition — all of which can catch the early stages of a wiring or gas valve fault before it causes a lockout.

Affected models: Potterton Promax, Potterton Promax Store, Potterton Performa, Potterton Titanium, Potterton Gold

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Potterton E09 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →