Potterton E134 Fault Code: Causes, Fixes & Repair Costs

What does the Potterton E134 fault code mean?

The E134 fault code appears when the boiler's PCB (printed circuit board) has sent the signal to open the gas valve, but the boiler cannot confirm that gas is actually reaching the burner. Because the boiler cannot establish a flame within the allowed time window, it locks out as a safety precaution. This is sometimes described as 'elapsed time gas valve open without gas' — essentially the boiler tried to fire, waited, and detected nothing. Do not repeatedly reset the boiler; if the underlying cause has not been fixed, the lockout will simply repeat, and persistent resets on a gas-flow fault carry a safety risk.

Lockout — engineer likely May need a Gas Safe engineer 4 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check your other gas appliances DIY safe

    Turn on a gas hob ring or check another gas appliance in the property. If nothing is working, the issue is likely with the mains gas supply rather than the boiler itself. In that case, contact your gas network operator (e.g. Cadent, SGN, or Wales & West Utilities) rather than a boiler engineer.

  2. Check the gas isolation valve on the boiler supply pipe DIY safe

    Locate the gas isolation valve on the pipe leading into the boiler — when the slot is parallel to the pipe, the valve is open; when it is perpendicular, it is closed. Ensure it is fully open. Do not touch any other valves or gas fittings.

  3. Attempt a single reset DIY safe

    If the gas supply appears normal, press and hold the reset button (or follow the reset procedure in your boiler's user guide) once. Allow the boiler to run through its ignition sequence. If it fires and runs normally, monitor it over the next 24 hours. If it locks out again, do not keep resetting — move to the next step.

  4. Call a Gas Safe registered engineer to diagnose the fault Gas Safe engineer

    If the boiler locks out again after one reset, or if you have any doubt about the gas supply, contact a Gas Safe registered engineer. They will carry out gas pressure tests, inspect the gas valve electrically and mechanically, check PCB outputs, and advise whether adjustment, a valve replacement, or a PCB replacement is needed. You can verify an engineer's Gas Safe registration at gassaferegister.co.uk.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £200–£420, depending on the underlying cause.

Frequently asked questions

Can I reset the boiler myself when E134 appears?

You can try a single reset to see whether it was a one-off ignition failure, but that is as far as a homeowner should go. If the boiler locks out again with E134, do not keep pressing reset. Repeatedly restarting the boiler when gas flow is not being confirmed is a safety risk, and the root cause — whether a pressure issue, a stuck valve, or a PCB fault — will not resolve itself through resetting.

How much does it cost to fix a Potterton E134 fault?

Most people pay somewhere between £200 and £420 for a diagnosis and repair, depending on what the engineer finds. A gas valve recalibration at the lower end of the scale costs relatively little beyond the callout and labour. A gas valve replacement typically adds up to around £300 all-in for parts and labour. A PCB replacement can reach £450–£550 and is worth weighing against the age and overall condition of the boiler — if other major components are also showing wear, a new boiler may be more cost-effective.

Is E134 the same fault on all Potterton boilers?

The E134 code carries the same fundamental meaning across Potterton's gas boiler range — the PCB opened the gas valve but detected no gas flow. However, the specific gas valve part number, its location, and the PCB design vary between models such as the Promax, Promax Store, Performa, and Titanium. Always give your engineer the full model name and serial number so they can source the correct components.

Should I replace my boiler rather than repair it when E134 appears?

It depends on the boiler's age and wider condition. If the fix is a valve recalibration or a straightforward valve swap and the rest of the boiler is in good shape, repair is usually the better value. If the engineer also finds issues with the pump, fan, heat exchanger, or other expensive parts, the combined repair cost may approach or exceed the cost of a new, more efficient boiler. Ask your engineer to give an honest assessment of the boiler's overall condition before committing to an expensive repair.

Affected models: Potterton Promax, Potterton Promax Store, Potterton Performa, Potterton Titanium

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Potterton E134 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →