Potterton E87 Fault Code: Causes, Fixes & Repair Costs

What does the Potterton E87 fault code mean?

The E87 fault code on a Potterton boiler indicates that the boiler has lost communication with the room controller or thermostat. In plain terms, the boiler cannot 'hear' the device that is supposed to tell it when to fire up. This is part of a family of related communication fault codes — E83, E84, E85, E86, and E87 — all of which point to a breakdown in the link between the room controller and the boiler. While the specific sub-code displayed can hint at whether the issue is with pairing, signal quality, or the controller itself, the root cause category is the same across all five. Importantly, E87 is not a gas-safety fault; it will not put your household at risk from gas or carbon monoxide. However, it will typically prevent your heating and hot water from working normally until the communication link is restored.

Engineer may be needed Some DIY checks possible 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Reset the boiler DIY safe

    Locate the reset button on your Potterton boiler's control panel and hold it for approximately three to five seconds. If the E87 code returns quickly after resetting, do not keep repeating the reset more than two or three times in total — a persistent fault needs investigation rather than repeated resets.

  2. Check the room thermostat has power DIY safe

    If you have a wireless thermostat, check that its batteries are not flat and replace them if needed. For a wired thermostat, confirm that power is reaching the unit. A thermostat with no power cannot send any signal to the boiler.

  3. Re-pair the thermostat with the boiler receiver DIY safe

    Consult the pairing section of your thermostat's instruction manual. Most Potterton-compatible wireless thermostats have a dedicated pairing button or a menu option to re-establish the link with the boiler receiver. Follow the steps carefully — the receiver usually needs to be put into 'learn' mode at the same time. A successful re-pair will often clear the E87 fault immediately.

  4. Check and change the RF channel if neighbours use a similar thermostat DIY safe

    If you suspect signal interference from a neighbouring property, your thermostat manual will explain how to change the radio channel. Both the thermostat head and the receiver unit must be set to the same new channel. Try at least two or three different channels and reset the boiler after each change to see if the fault clears.

  5. Visually inspect any accessible thermostat wiring DIY safe

    On wired installations, switch off the boiler at the fused spur before touching any wiring. Check the terminals at the thermostat backplate and at the boiler connection point for obvious signs of looseness, corrosion, or damage. Gently re-seat any loose cables. Do not attempt to work on wiring inside the boiler casing — this must be done by a qualified engineer.

  6. Call a Gas Safe registered engineer if the fault persists Gas Safe engineer

    If re-pairing, channel changes, and a boiler reset have not cleared the E87 code, the fault lies with components that need professional diagnosis — most likely the wiring inside the boiler, the receiver unit, or the PCB. A Gas Safe registered engineer will carry out a full electrical diagnostic, test the communication circuit, and replace whichever component is at fault. Do not attempt to open the boiler casing yourself.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£350, depending on the underlying cause.

Frequently asked questions

Is the Potterton E87 fault code dangerous?

No. Unlike fault codes that relate to gas pressure, flue gases, or ignition failures, E87 is purely an electrical communication error between the thermostat and the boiler. It poses no direct safety risk from gas or carbon monoxide. Your boiler will typically lock out or run in a limited mode until the communication link is restored, but you do not need to evacuate or isolate the gas supply.

What is the difference between E83, E84, E85, E86, and E87 on a Potterton boiler?

All five codes belong to the same communication fault family and indicate the boiler has lost contact with the room controller. The slight differences between them point to where in the communication process the breakdown is occurring — for example, E83 may suggest no signal is being received at all, while E85–E87 can indicate the signal is being received but is invalid or out of sync. In practice, the diagnosis and fix are very similar for all five: start with re-pairing the thermostat and checking the wiring before escalating to an engineer.

Can I fix the E87 fault myself without calling an engineer?

Quite possibly, yes. The most common cause is simply a lost pairing between a wireless thermostat and the boiler receiver, which you can fix yourself by following the re-pairing instructions in your thermostat's manual. Replacing flat batteries and changing the RF channel are also straightforward homeowner tasks. If these steps do not work, however, the fault is likely inside the boiler — wiring or the PCB — and you will need a Gas Safe registered engineer to investigate safely.

How much does it cost to fix a Potterton E87 fault code in the UK?

For the most common cause — a thermostat replacement or re-pairing job — you can expect to pay roughly £100–£350 including parts and an engineer's call-out. Wiring repairs tend to sit at the lower end of that range. If the PCB turns out to be the culprit, parts and labour can push the total to £450–£700 depending on your region and the specific board required; this is worth bearing in mind on older boilers where the overall value of further repairs should be weighed against the cost of a replacement boiler.

Affected models: Potterton Assure, Potterton Titanium, Potterton Profile, Potterton Performa, Potterton Gold

Last reviewed 8 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Potterton E87 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →