P

Protherm F.42 Fault Code: Causes, Fixes & Repair Costs

What does the Protherm F.42 fault code mean?

The F.42 code appears on Protherm boilers when the control board detects that the coding resistor (R1) is returning a value outside the expected range. The coding resistor is a small component on the PCB that effectively tells the boiler's electronics what type of appliance it is and how it should behave. When this value doesn't match what the board expects — whether because the resistor has failed, the wrong product code was programmed in at installation, or the PCB itself is damaged — the boiler locks out and displays F.42 as a safety precaution. This is a board-level electronic fault and sits in the more serious category of Protherm error codes (F.20–F.42), meaning it will not clear on its own without the underlying issue being addressed.

Lockout — engineer likely May need a Gas Safe engineer 4 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Do not keep resetting the boiler repeatedly DIY safe

    Unlike some simple lockouts, F.42 is an electronic fault that will not resolve itself with repeated resets. One reset attempt is fine to confirm the fault persists, but cycling the power repeatedly risks stressing other components on the board. If the code returns immediately after a reset, leave the boiler off and move to the next steps.

  2. Check your gas supply is working DIY safe

    Before calling an engineer, quickly confirm that other gas appliances in your home (such as a gas hob) are functioning normally. This rules out a wider gas supply interruption as a contributing factor, though it is unlikely to be the direct cause of F.42.

  3. Note whether F.42 is alternating with F.70 DIY safe

    If your display is cycling between F.42 and F.70, make a note of this and tell your engineer. This pattern strongly suggests the issue is an incorrectly programmed product code rather than a hardware failure, which is a quicker and cheaper fix.

  4. Have a Gas Safe engineer measure the resistance of R1 Gas Safe engineer

    An engineer will isolate the boiler electrically, access the control board, and use a calibrated multimeter to measure the resistance of R1. The reading is compared against the value specified in the Protherm technical documentation for your specific model. If the resistor is out of tolerance, it can be replaced without necessarily changing the entire PCB.

  5. Ask the engineer to verify the programmed product code Gas Safe engineer

    If R1 measures within specification, the engineer should check the installation menu to confirm the correct product code is entered for your exact boiler model and output rating. Correcting a misconfigured code is a simple fix that avoids unnecessary component replacement.

  6. Replace the PCB if R1 and the product code are both correct Gas Safe engineer

    If the coding resistor tests correctly and the product code is accurate, the fault lies within the control board itself. A Gas Safe engineer will source and fit a compatible replacement PCB for your Protherm model, re-programme it correctly, and verify the boiler fires and operates safely before leaving.

  7. Call a Gas Safe registered engineer Gas Safe engineer

    All of the diagnostic and repair work for F.42 involves the boiler's electrical control board and must be carried out by a qualified Gas Safe registered engineer. You can verify an engineer's registration at the Gas Safe Register website (gassaferegister.co.uk). Ask them to diagnose whether only R1 needs attention or whether a full PCB swap is required, as this significantly affects the cost.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£380, depending on the underlying cause.

Frequently asked questions

Can I fix a Protherm F.42 fault myself?

No — this is not a homeowner repair. The F.42 fault is rooted in the boiler's electronic control board, and any work on PCB components must be carried out by a Gas Safe registered engineer. There are no homeowner-safe checks that will resolve this fault beyond a single reset attempt.

How much does it typically cost to repair a Protherm F.42 fault?

Most people pay somewhere between £150 and £380 all-in, depending on whether the coding resistor alone needs replacing (cheaper, around £150–£200 including labour and call-out) or whether the entire PCB needs swapping (typically £250–£380 for parts and labour). If your boiler requires a particularly hard-to-source board, costs can occasionally climb higher — worth factoring in if the boiler is over ten years old.

Why is F.42 sometimes showing alongside F.70 on my Protherm boiler?

If your display alternates between F.42 and F.70, this is a strong indicator that the product code entered in the boiler's installation menu does not match the actual model. This is a programming issue rather than a hardware failure and is typically one of the quicker fixes — your engineer simply needs to access the installation settings and enter the correct code for your specific Protherm appliance.

Is it worth repairing a Protherm boiler showing F.42, or should I replace it?

If your boiler is under ten years old and otherwise in good condition, repair is almost always the more cost-effective route. If it is older than ten to twelve years, already needed several repairs recently, or spare parts are difficult to source, it may be worth getting a quote for a new boiler alongside the repair estimate. A Gas Safe engineer can give you an honest view of the boiler's overall condition during the diagnostic visit.

Affected models: Protherm Gepard (Cheetah), Protherm Panther, Protherm Bear, Protherm Tiger

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.