Ravenheat E31 Fault Code: Causes, Fixes & Repair Costs

What does the Ravenheat E31 fault code mean?

The E31 code on a Ravenheat boiler signals that the OpenTherm communication link between the boiler and its connected thermostat or controller has broken down. OpenTherm is a digital, two-way protocol that allows a compatible thermostat to continuously adjust the boiler's heat output in real time — rather than simply switching it on and off. When E31 appears, this dialogue has been interrupted, and the boiler cannot receive the commands it needs to operate correctly. The fault may be triggered by something as minor as flat thermostat batteries or a temporary signal dropout, but it can also point to wiring issues, a faulty thermostat receiver, or a problem with the boiler's PCB.

Lockout — engineer likely Some DIY checks possible May need a Gas Safe engineer 4 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Reset the boiler DIY safe

    Press the reset button (or cycle the boiler's on/off switch, depending on your model) to attempt to clear the fault. A temporary communication dropout will often resolve itself after a single reset. If the fault clears and does not return within a normal heating cycle, no further action is needed. Avoid resetting more than two or three times — repeated resets without resolution suggest an underlying fault that needs investigation.

  2. Check and replace the thermostat batteries DIY safe

    If your OpenTherm thermostat runs on batteries, remove them and fit a fresh set. Even batteries that show a partial charge can struggle to maintain a stable communication signal. After fitting new batteries, allow the thermostat a minute or two to reconnect, then attempt a boiler reset.

  3. Check that the thermostat has power and is switched on DIY safe

    Confirm the thermostat display is active and that it has not been accidentally switched off or lost its mains power supply (for hardwired models). Check any associated fuse spur is switched on and has not tripped.

  4. Gently clean the thermostat DIY safe

    If your thermostat has an accessible interior (such as a removable cover), use a dry, soft brush or a can of compressed air to remove any visible dust from around the circuit board and terminals. Do not use water or spray cleaners. Reassemble, restore power, and retry the boiler reset.

  5. Inspect wiring connections between the thermostat and boiler Gas Safe engineer

    A heating engineer should check the OpenTherm wiring terminals at both the thermostat and the boiler for loose connections, corrosion, or cable damage. The two OpenTherm wires carry both power and data, so even a partially loose terminal can cause intermittent faults. This work requires knowledge of the boiler's wiring diagram and should not be attempted by a homeowner.

  6. Test or replace the thermostat and receiver Gas Safe engineer

    A heating engineer can use diagnostic equipment to determine whether the thermostat or its wireless receiver is generating a valid OpenTherm signal. If the device is found to be faulty or incompatible with your Ravenheat boiler, replacing it with a confirmed-compatible OpenTherm controller will resolve the E31 fault.

  7. Have the boiler PCB inspected and replaced if necessary Gas Safe engineer

    If the wiring, thermostat, and receiver all test correctly, the fault is likely to lie within the boiler's PCB — specifically the OpenTherm communication circuitry. A Gas Safe registered engineer can test the PCB and advise whether repair or replacement is appropriate. On older Ravenheat boilers, the cost of a new PCB may make full boiler replacement a more sensible option.

  8. Call a Gas Safe registered engineer Gas Safe engineer

    If the fault persists after you have tried the homeowner checks above, contact a Gas Safe registered engineer. They can carry out a full diagnostic of the OpenTherm system, wiring, thermostat, and boiler PCB, and carry out any necessary repairs safely and correctly.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £60–£300, depending on the underlying cause.

Frequently asked questions

Can I fix the Ravenheat E31 fault myself?

Some of the most common causes are absolutely within a homeowner's reach — replacing flat batteries, cleaning the thermostat, and resetting the boiler cost nothing and take only a few minutes. However, if those steps do not clear the fault, you will need a heating engineer to investigate the wiring, thermostat receiver, or boiler PCB. Gas components and PCB work must always be handled by a Gas Safe registered professional.

Will the E31 fault come back after a reset?

If the original cause was a one-off communication glitch, a single reset is usually enough and the fault will not return. If E31 reappears after each heating cycle or within a few hours of resetting, there is an underlying fault — most likely with the wiring, the thermostat, or the boiler PCB — that needs a proper diagnosis rather than repeated resetting.

How much does it cost to fix the Ravenheat E31 fault?

Most people with an E31 fault pay somewhere between £60 and £300 all in. A straightforward thermostat replacement or wiring repair typically falls at the lower end of that range. If the boiler's PCB turns out to be the cause, parts and labour can push the bill towards £400 or more. On Ravenheat boilers that are over ten years old, a full boiler replacement is often better value than replacing a PCB, and a new condensing boiler will typically cut your heating bills as well.

Is OpenTherm the same as a standard on/off thermostat connection?

No — they are quite different. A conventional thermostat simply switches the boiler on when heat is needed and off when the set temperature is reached. An OpenTherm thermostat communicates digitally with the boiler, continuously adjusting the target flow temperature to match demand. This modulating control is more efficient but requires both devices to speak the same OpenTherm protocol. If you swap your thermostat for a non-OpenTherm model, the E31 fault will clear but you will lose the efficiency benefits of modulation.

Affected models: Ravenheat RSF range, Ravenheat LS range, Ravenheat CSI range, Any Ravenheat boiler with OpenTherm connectivity

Last reviewed 2 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Ravenheat E31 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →