Remeha A.02.06 Fault Code: Causes, Fixes & Repair Costs

What does the Remeha A.02.06 fault code mean?

The A.02.06 code is Remeha's water pressure warning, meaning the system pressure has dropped below the minimum threshold needed for safe, reliable operation. Unlike a full lockout, the boiler may continue running in a reduced state, but the fault must be addressed promptly. Left unattended, the warning can escalate first to a blocking (boiler stops heating) and then to a lockout (manual reset required). The target pressure for most Remeha systems is between 1 and 2 bar when cold; anything below 1 bar will typically trigger this warning.

Engineer may be needed Some DIY checks possible 4 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the pressure gauge DIY safe

    Locate the pressure gauge on the boiler — it may be a dial gauge or a digital reading in the boiler's display menu. A healthy cold-system pressure is typically 1–1.5 bar. If it reads below 1 bar, the system needs topping up. If it reads within range and the warning is still showing, the sensor itself may be at fault.

  2. Top up the system pressure using the filling loop DIY safe

    Most Remeha boilers use either a built-in Easyfill link (a green lever or knob under the appliance) or an external braided filling loop with two isolation valves. Slowly open the valve(s), watch the gauge rise to around 1.2–1.5 bar, then close the valve(s) fully. Never overfill beyond 2 bar. Refer to your boiler's user guide for the exact filling procedure for your model.

  3. Reset the boiler DIY safe

    Once pressure is back in range, press and hold the reset button (usually marked with a flame and line symbol) for a few seconds until the boiler attempts to restart. If it fires up and the warning clears, monitor the pressure over the next few days. Avoid resetting more than two or three times without understanding why the fault appeared.

  4. Inspect all accessible pipework and radiators for leaks DIY safe

    Walk around the property checking every radiator, thermostatic radiator valve (TRV), lockshield valve, and any visible pipe runs for signs of dripping water, damp patches on walls or floors, or white limescale residue. Also check under the boiler casing (if accessible without tools) and look outside for drips from the PRV discharge pipe.

  5. If pressure keeps dropping, arrange a Gas Safe engineer visit Gas Safe engineer

    If the system pressure falls below 1 bar again within a few days of repressurising — particularly without any obvious external leak — there is likely an underlying problem such as a failing expansion vessel, a weeping PRV, or a hidden internal leak. A Gas Safe registered engineer can test the expansion vessel charge, inspect internal components, and carry out the necessary repair safely. Do not continue to repressurise repeatedly as a long-term fix.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £80–£350, depending on the underlying cause.

Frequently asked questions

Can I fix the Remeha A.02.06 warning myself?

In many cases, yes. If the system pressure has simply dropped below 1 bar — perhaps after bleeding radiators — repressurising via the filling loop is a straightforward DIY task described in your boiler's user guide. However, if the pressure keeps dropping or you cannot find a reason for the loss, you should call a Gas Safe engineer rather than repeatedly topping up, as you could be masking an internal leak or a failed expansion vessel.

How often should my boiler lose pressure?

A properly sealed central heating system should hold its pressure for months without needing a top-up. Losing more than around 0.2–0.3 bar in a few days is a sign something is wrong. Occasional small drops over a year are normal due to dissolved gases escaping, but frequent drops — especially after repressurising — almost always point to a leak or a faulty expansion vessel.

How much does it cost to fix low boiler pressure in the UK?

If you can repressurise the boiler yourself, there is no cost. An engineer callout to do the same typically runs £80–£150 depending on your area. If an expansion vessel needs recharging or replacing, expect £150–£350 including parts and labour. A pressure sensor or PRV replacement usually sits in the £100–£200 range all-in. Complex internal leaks or a heat exchanger issue can push costs considerably higher — a Gas Safe engineer's diagnosis will clarify what is needed.

What is the correct pressure for a Remeha boiler?

Remeha recommends a cold-fill pressure of 1–2 bar for most of their residential combi and system boilers. A setting of around 1.2–1.5 bar when the system is cold gives a comfortable margin — it will rise slightly when the heating is running, but should not exceed 2.5–3 bar at full operating temperature. If the gauge regularly climbs above 2.5 bar when hot, the expansion vessel may not be doing its job correctly.

Affected models: Remeha Quinta Ace, Remeha Avanta, Remeha Calenta, Remeha Tzerra

Last reviewed 2 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Remeha A.02.06 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →