Remeha E.00.17 Fault Code: Causes, Fixes & Repair Costs

What does the Remeha E.00.17 fault code mean?

The E.00.17 fault code appears on Remeha boilers — most commonly the Quinta Ace commercial and semi-commercial range — and sits within the E.00.XX series, which monitors thermal sensors and water-circuit parameters. Based on the numbering pattern of verified nearby codes (E.00.04 covers the return temperature sensor; E.00.40 covers the water pressure sensor), E.00.17 most likely relates to a flow temperature sensor fault or a maximum flow temperature monitoring anomaly. In plain terms, the boiler's control board has detected a reading from a temperature sensor that is outside its expected range — either an implausibly high or low value, or no signal at all — and has locked out as a safety precaution. Because the full Quinta Ace service documentation is not freely indexed online, the precise trigger condition for E.00.17 is best confirmed by an authorised Remeha engineer with access to the official commissioning manual for your specific model and generation. If you see this code, note down your exact boiler model and serial number before taking any action.

Lockout — engineer likely May need a Gas Safe engineer 6 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Note down the full fault code, boiler model, and serial number DIY safe

    Before you do anything else, write down 'E.00.17', your boiler's model name (e.g. Quinta Ace 65), and the serial number from the data plate. If you have to call Remeha technical support (Remeha House, Wokingham, Berkshire) or an engineer, this saves time and ensures they can pull the correct service documentation.

  2. Check that your gas supply is working DIY safe

    Confirm other gas appliances in your property — a gas hob or fire — are functioning normally. If there is no gas supply to the property, contact your gas supplier rather than resetting the boiler.

  3. Attempt a single boiler reset DIY safe

    Press and hold the reset button on the boiler's front panel for the time specified in your user guide (typically 3–5 seconds). Wait at least 60 seconds to see whether the boiler fires up normally. If it locks out again with E.00.17, do not reset more than two or three times in total — repeated resets on a genuine sensor or overtemperature fault will not fix the underlying problem and can mask important diagnostic information.

  4. Check system pressure DIY safe

    Glance at the pressure gauge or digital pressure reading. For most Remeha systems, normal operating pressure is between 1.0 and 2.0 bar when cold. If pressure is below 0.5 bar, top it up via the filling loop following your user manual's instructions. Low pressure alone is unlikely to cause E.00.17 specifically, but it is worth ruling out before calling an engineer.

  5. Have a Gas Safe engineer inspect the flow temperature sensor and its wiring Gas Safe engineer

    An engineer will locate the flow temperature sensor on the primary circuit, inspect its mounting clip and insulation, and test its resistance with a multimeter to check it falls within the manufacturer's specified range. They will also check the wiring loom back to the PCB connector for continuity and insulation integrity. This work involves accessing internal boiler components and must be carried out by a qualified Gas Safe registered engineer.

  6. Engineer to test and replace the sensor if required Gas Safe engineer

    If the thermistor is out of specification, the engineer will replace it with the correct Remeha-approved part (such as temperature sensor part 720480501, available from UK Remeha spares stockists). After replacement, the fault code must be cleared from the boiler's memory and the unit recommissioned to confirm normal operation.

  7. Engineer to inspect the PCB if the fault persists after sensor replacement Gas Safe engineer

    Should the E.00.17 code return following a confirmed sensor and wiring replacement, the control board itself may have a faulty sensor-input channel. PCB diagnosis and replacement is a specialist task and must remain with a Gas Safe engineer; fitting the wrong board or incorrect firmware version can cause further faults.

  8. Call a Gas Safe registered engineer if you have not already done so Gas Safe engineer

    If the boiler has not responded to a reset and you are unable to identify an obvious cause such as low pressure, contact a Gas Safe registered engineer. When booking, give them the full code (E.00.17), your boiler model, and its approximate age. You can verify any engineer's Gas Safe registration at GasSafeRegister.co.uk before they visit.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£350, depending on the underlying cause.

Frequently asked questions

Is E.00.17 dangerous — do I need to leave my home?

An E.00.17 lockout means the boiler has shut itself down safely as a precaution; it is not a gas-leak or carbon-monoxide alarm. You do not need to evacuate, but you should not attempt to bypass the lockout or reset the boiler repeatedly. If you smell gas at any point, leave the property, avoid using electrical switches, and call the National Gas Emergency Service on 0800 111 999.

Can I fix E.00.17 myself, or do I need an engineer?

A homeowner can safely attempt one or two resets and check system pressure via the filling loop. Beyond that, diagnosing and replacing a temperature sensor, testing wiring, or assessing the PCB all require access to internal boiler components — this work must be done by a Gas Safe registered engineer. Remeha also recommends that servicing and fault clearance on the Quinta Ace range be carried out by an authorised Remeha engineer with access to the correct service documentation.

How much will it cost to fix E.00.17?

If the cause is a faulty flow temperature sensor and the wiring is undamaged, most UK homeowners pay in the region of £120–£350 including parts and labour (sensor parts typically cost £30–£50; a Gas Safe engineer's call-out and diagnostic labour typically runs £80–£150). If the fault has led to PCB damage, a replacement board can add £200–£350 to the bill, though this is uncommon for a straightforward sensor fault. Booking a standard appointment rather than an emergency call-out will keep costs down.

Why does E.00.17 keep coming back after I reset it?

Repeated lockouts after a reset almost always mean the underlying fault — most likely a degraded sensor, a loose wiring connection, or a genuine overtemperature condition — has not been resolved. Resetting clears the lockout temporarily but does not fix the hardware. If the code returns more than twice, stop resetting and arrange for a Gas Safe engineer to investigate; persistent resets can obscure fault-history data that helps an engineer diagnose the problem more quickly.

Which Remeha boilers show E.00.XX fault codes?

The E.00.XX series is associated primarily with the Remeha Quinta Ace and Quinta Pro commercial and semi-commercial condensing boilers. The domestic Avanta range uses a different, simpler fault-code format (E0, E1, E2, etc.). If you own an Avanta and see a code beginning with 'E.00', double-check the display — it may be showing a different format. If you are unsure which range your boiler belongs to, the model name is printed on the data label inside the front panel.

Affected models: Remeha Quinta Ace, Remeha Quinta Pro, Remeha Quinta Ace 45, Remeha Quinta Ace 65, Remeha Quinta Ace 90, Remeha Quinta Ace 115

Last reviewed 15 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Remeha E.00.17 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →