Remeha E.04.18 Fault Code: Causes, Fixes & Repair Costs

What does the Remeha E.04.18 fault code mean?

The Remeha E.04.18 fault is part of the E04 (also shown as E4) ignition lockout family, with the .18 sub-code providing a more granular diagnostic on newer models such as the Quinta and Avanta ranges. In plain terms, the boiler attempted to light and failed — so it has shut itself down as a safety precaution. The three underlying scenarios covered by sub-codes in this family are: (1) no ignition spark is produced at all, (2) a spark is generated but no flame forms, or (3) a flame is present but the ionisation current detected is below the safe threshold of around 3 µA. In all three cases the boiler locks out and will not restart until the fault is investigated and the unit is manually reset. This lockout behaviour is intentional — it stops the boiler from repeatedly attempting to fire gas into a chamber where combustion cannot be confirmed, which would be dangerous.

Lockout — engineer likely May need a Gas Safe engineer 6 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check that other gas appliances in your home are working DIY safe

    Turn on your gas hob, oven, or gas fire to confirm gas is reaching your property. If none of your gas appliances work, the issue is with your gas supply rather than the boiler — contact your gas supplier or call the National Gas Emergency Service on 0800 111 999 if you suspect a leak.

  2. Check your system pressure DIY safe

    Look at the pressure gauge on the boiler — it should read between 1.0 and 1.5 bar when cold. If it has dropped below 0.8 bar, top it up using the filling loop (usually a flexible braided hose or a built-in valve beneath the boiler). Fill slowly until the gauge reaches around 1.2 bar, then close the valve fully. Do not overfill above 2.5 bar.

  3. In cold weather, check for a frozen condensate pipe DIY safe

    Locate the white plastic condensate pipe — usually 21 mm or 32 mm diameter — that exits the boiler and runs to an external drain or gulley. If it feels solid or you can see ice around the joint, it is likely frozen. Gently thaw it by pouring warm (not boiling) water along the pipe or wrapping it in a warm cloth. Once cleared, reset the boiler. Consider lagging the pipe to prevent a recurrence.

  4. Reset the boiler once DIY safe

    Press and hold the reset button (consult your user manual for its location — on most Remeha models it is clearly labelled on the control panel) for around three seconds. Allow the boiler a full minute to complete its start-up sequence. If it fires successfully, monitor it over the next hour to confirm it stays running. Do not reset more than two or three times in total — repeated resets without fixing the underlying fault are unsafe.

  5. If the boiler locks out again, stop resetting and call a Gas Safe registered engineer Gas Safe engineer

    Continuing to reset a boiler that keeps locking out asks the boiler to repeatedly attempt ignition despite a fault it has already judged unsafe. An engineer will carry out a systematic inspection: testing the ignition and ionisation electrode (and replacing it along with the burner gasket service kit if needed), checking gas supply pressure and the gas valve operation, inspecting the flue for blockages or recirculation, testing all cabling to the ignition transformer and electrode, and assessing the PCB only after all other causes have been excluded. You can verify a Gas Safe engineer's registration at gassaferegister.co.uk.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£350, depending on the underlying cause.

Frequently asked questions

Can I fix a Remeha E.04.18 fault myself?

There are a handful of checks a homeowner can safely carry out: confirming the gas supply is live, topping up boiler pressure, thawing a frozen condensate pipe in cold weather, and attempting a single reset. Beyond that, any work inside the boiler — including touching the electrode, the gas valve, the burner, or the PCB — must be done by a Gas Safe registered engineer. It is illegal for an unregistered person to work on gas appliances in the UK, and doing so also invalidates your home insurance.

Why does my Remeha boiler keep coming back with E04 after I reset it?

A lockout that returns after resetting almost always means the root cause has not been addressed. Common culprits for a recurring E04 include a worn or cracked ignition/ionisation electrode, deteriorated burner seals allowing combustion air to escape, a gas valve that is not opening correctly, or a flue issue causing exhaust gas recirculation. Repeatedly resetting without a repair is both ineffective and potentially unsafe — call a Gas Safe engineer who can diagnose and fix the underlying fault.

How much does it typically cost to repair a Remeha E.04.18 fault?

Most homeowners pay between £120 and £350 all-in for this type of fault, which usually covers the call-out, an electrode replacement (often supplied as part of a service kit including burner gaskets), and labour. A gas valve replacement sits towards the higher end at roughly £200–£300 including parts and labour. If the PCB turns out to be the cause, the part alone can cost £250–£400 and the total bill may exceed £500 — though PCB faults are relatively rare and are only diagnosed once everything else has been checked. Prices in London and the South East are typically 15–25% higher, and out-of-hours or weekend callouts attract a further uplift of 30–50%.

My Remeha boiler is showing E04 in freezing weather — is it the condensate pipe?

Very possibly, yes. When outdoor temperatures drop below zero, the external condensate drain pipe can freeze, causing condensate to back up inside the boiler and trigger a lockout. The boiler may display it as an E04 ignition fault because it cannot complete a firing sequence. You can safely attempt to thaw the pipe yourself using warm water poured along its length. Once the blockage clears, reset the boiler. If it fires and stays on, lagging the exposed section of pipe will help prevent a repeat. If the fault returns or the pipe does not appear to be frozen, another cause is likely and an engineer visit is needed.

Affected models: Remeha Quinta, Remeha Quinta Ace, Remeha Avanta, Remeha Avanta Plus, Remeha Calenta, Remeha Gas 210 Eco

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer