Remeha E5 Fault Code: Causes, Fixes & Repair Costs

What does the Remeha E5 fault code mean?

The E5 fault code on Remeha boilers — most commonly seen on the Avanta and Avanta Plus — indicates that the boiler has attempted to ignite and establish a stable flame but has failed to confirm one through its ionisation sensing system. Specifically, the boiler made five or more unsuccessful attempts to detect a valid ionisation signal during a single heat demand before locking out for safety. The ionisation current needs to sit between 3 and 9 microAmperes for the boiler to accept the flame as stable; if that threshold is not consistently met, the boiler shuts down. This is a lockout fault, meaning the boiler will not restart automatically and must be reset — though a reset alone will rarely cure the underlying problem.

Lockout — engineer likely May need a Gas Safe engineer 4 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check that your gas supply is working normally DIY safe

    Turn on a gas hob or check another gas appliance in the property. If nothing works, there may be a supply interruption — contact your gas network operator (e.g. Cadent, SGN, or Northern Gas Networks). Do not attempt to work on any gas pipework yourself.

  2. Reset the boiler (once or twice only) DIY safe

    Press and hold the reset button for a few seconds until the boiler attempts to restart. You can try this up to two or three times, but if E5 returns each time it is a clear sign the underlying fault has not been resolved. Repeated resets without a repair will not help and may mask the problem.

  3. Check the system pressure DIY safe

    Look at the pressure gauge on the boiler front panel. It should read between 1.0 and 1.5 bar when the system is cold. If it is below 0.8 bar, top it up via the filling loop following the instructions in your boiler manual. Low pressure alone is unlikely to cause E5 but is worth ruling out.

  4. Book a Gas Safe registered engineer for a full combustion inspection Gas Safe engineer

    A qualified engineer should carry out combustion analysis, check the ionisation current with a microAmmeter, inspect the electrode and burner gasket, verify the flue and air-inlet connections, and adjust the CO₂ setting on the gas block. On the Remeha Avanta, experienced engineers typically fit a service kit (which includes the electrode and related consumables) plus a new ignition transformer as a package, then re-commission with combustion analysis.

  5. Engineer to inspect and replace the burner gasket if needed Gas Safe engineer

    The burner bar gasket is a common and inexpensive cause of E5. The engineer should remove the burner assembly, inspect the gasket for cracking or distortion, and replace it. Remeha recommend this is done approximately every two years regardless.

  6. Engineer to check thermostat parameter P5 if fault persists Gas Safe engineer

    If the boiler is connected to a room thermostat that incorporates an anticipation resistor, the engineer should access the boiler's installer parameters and confirm that P5 is set to 1 rather than the default of 0. This is a documented cause of recurring E5 faults that is easily overlooked.

  7. Engineer to test or replace the ignition transformer and, as a last resort, the PCB Gas Safe engineer

    If all combustion components and settings have been addressed but E5 continues to return, the ignition transformer output should be measured. A weak or inconsistent output confirms the transformer needs replacing. Should the transformer also prove sound, the PCB may be at fault and will need to be replaced by a qualified engineer.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£380, depending on the underlying cause.

Frequently asked questions

Can I fix the Remeha E5 fault myself without calling an engineer?

Your only safe homeowner actions are to check the gas supply is on, try a reset once or twice, and verify the system pressure. Everything else — adjusting the gas block, replacing electrodes, checking the ignition transformer, or accessing boiler parameters — must be carried out by a Gas Safe registered engineer. Working on gas appliances without the correct registration is illegal and dangerous.

Will resetting the boiler clear the E5 fault permanently?

Almost certainly not. A reset gets the boiler running again temporarily, but if the underlying cause — a worn electrode, failed burner gasket, incorrect CO₂ setting, or similar — has not been fixed, the fault will return, often within the same heating cycle. Repeated resets without a proper repair can delay diagnosis and sometimes cause additional wear. Book an engineer rather than relying on resets.

How much does it typically cost to repair a Remeha E5 fault?

Most homeowners pay somewhere between £150 and £380 all-in, depending on which components need attention. A full service with a new electrode kit, burner gasket, and combustion re-commissioning tends to fall in the £150–£250 range. If the ignition transformer also needs replacing, add roughly £100–£150 to that. A gas valve replacement usually costs £200–£350 including labour. The PCB is the most expensive possibility — parts alone can reach £250–£300, with the total repair typically £350–£500 — but PCB replacement is a last resort and is worth mentioning to your engineer before agreeing to it.

Could the Remeha E5 fault be caused by my thermostat?

Yes, in some cases. If your room thermostat has an anticipation resistor built in, there is a documented parameter setting — P5 — inside the boiler that must be changed from 0 to 1 to suit that thermostat type. Without this change, the boiler can cycle in a way that repeatedly triggers ignition failures and ultimately an E5 lockout. If your boiler has had electrodes and a gasket replaced but E5 keeps returning, ask your engineer to check the P5 parameter.

Affected models: Remeha Avanta, Remeha Avanta Plus, Remeha Avanta System, Remeha Quinta

Last reviewed 2 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Remeha E5 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →