Viessmann 94 Fault Code: Causes, Fixes & Repair Costs

What does the Viessmann 94 fault code mean?

Fault code 94 on Viessmann boilers signals that the solar control module has detected a short circuit on the domestic hot water (DHW) cylinder temperature sensor (referred to in Viessmann documentation as sensor %). When this sensor's electrical resistance collapses, the control module can no longer trust the temperature readings coming from the storage cylinder, so it suspends solar DHW heating as a precaution. Importantly, this is not necessarily a full boiler lockout — the main burner and central heating may continue to operate normally, but your solar thermal contribution to hot water will be inactive until the fault is cleared. Code 94 sits within a family of solar-related sensor fault codes: codes 90 and 91 relate to short circuits on other sensors at the solar control module, code 92 covers a short on the solar collector sensor, code 93 is a collector sensor short in control mode, and code 94 specifically points to the DHW tank sensor. If you see 94 on your display, the solar side of your system needs attention from a qualified engineer.

Engineer may be needed May need a Gas Safe engineer 2 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check that your boiler's main gas supply and mains power are both on DIY safe

    Before anything else, confirm that the gas isolation valve near the boiler is open and that the boiler has mains power. These are basic checks that rule out unrelated supply issues.

  2. Note whether central heating is still working DIY safe

    Fault code 94 targets solar DHW heating specifically. If your radiators are still warming up, the main boiler burner is likely unaffected. Make a note of what is and is not working — this helps the engineer diagnose quickly.

  3. Attempt a single boiler reset DIY safe

    Press and hold the reset button on your Viessmann boiler as described in your user guide (typically 3–5 seconds). Do this no more than once or twice. If the fault clears and solar DHW resumes, monitor the boiler closely. If code 94 returns, do not keep resetting — a recurring fault needs professional investigation.

  4. Inspect the cylinder sensor and its wiring visually (engineer task) Gas Safe engineer

    A Gas Safe registered engineer will locate the DHW cylinder temperature sensor (sensor %) and examine it for visible damage, corrosion, moisture ingress, or signs of heat stress. They will also trace the cable back to the solar control module looking for chafed or pinched insulation.

  5. Test plug-in connections at the solar control module (engineer task) Gas Safe engineer

    The engineer will check that all connectors at the solar control module or Vitosolic unit are fully seated, clean, and free from oxidation. Loose connections are an easy fix but must be done carefully to avoid damage to the module.

  6. Electrically test the sensor and wiring (engineer task) Gas Safe engineer

    Using a multimeter, the engineer will measure the resistance of the tank temperature sensor and continuity of the wiring loom. A shorted sensor will typically read close to 0 ohms rather than the expected resistance value for its temperature range.

  7. Replace the DHW cylinder temperature sensor if faulty (engineer task) Gas Safe engineer

    If testing confirms the sensor has failed, the engineer will fit a compatible replacement sensor and recheck the solar control module's readings before resetting the fault.

  8. Replace the solar control module if sensor and wiring are both sound (engineer task) Gas Safe engineer

    Should the sensor and cabling prove to be in good condition, the fault lies within the solar control module itself. The engineer will source and fit the correct replacement module for your Viessmann installation.

  9. Reset and verify the system (engineer task) Gas Safe engineer

    After the repair, the engineer will perform a controlled reset of the boiler control unit, confirm that fault code 94 has cleared, and verify that solar DHW heating has resumed correctly. They should also check that no related fault codes (90–93) are present.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£380, depending on the underlying cause.

Frequently asked questions

Will my boiler still heat my home if fault code 94 appears?

In most cases, yes. Fault code 94 suspends solar DHW heating — meaning the solar thermal panel contribution to your hot water cylinder is disabled — but the main gas burner can usually continue providing central heating and conventional (non-solar) hot water. Check whether your radiators and taps are still working normally and report this to the engineer when you call.

Can I fix Viessmann fault code 94 myself?

Resetting the boiler once or twice is the only DIY action worth trying. All other work — testing the sensor, checking wiring, replacing components on the solar control module — must be carried out by a Gas Safe registered engineer. Solar thermal systems are specialist equipment, and incorrect work could damage the control module or create an unsafe situation.

How much does it cost to repair fault code 94 in the UK?

Most homeowners pay between £120 and £380 all in, depending on what has failed. A wiring fault or loose connection is at the cheaper end; replacing the DHW tank sensor typically costs £100–£200 including labour. If the Vitosolic or solar control module itself needs replacing, costs can rise to £350–£500 or more, since the module itself can cost upwards of £200 before labour. Rates are generally higher in London and the South East.

Why does fault code 94 keep coming back after I reset the boiler?

A recurring code 94 means the underlying fault — most likely a failing sensor, degraded wiring, or a deteriorating solar control module — has not been resolved. Repeated resets will not fix a hardware fault and may mask the problem temporarily. If the code returns more than once or twice, stop resetting and book a Gas Safe engineer to carry out a proper diagnosis before the fault worsens.

Is fault code 94 covered under my Viessmann warranty?

It may be, depending on the age of your boiler and whether you have kept up with annual servicing by a Viessmann-accredited engineer. Viessmann's extended warranty terms typically require regular professional servicing — skipping a service can invalidate your cover and leave you paying the full repair cost. Check your warranty documentation or contact Viessmann UK directly to confirm your entitlement before booking a repair.

Affected models: Vitodens 200-W (with solar thermal integration), Any Viessmann boiler fitted with a Vitosolic or built-in solar control module

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Viessmann 94 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →