Vokera AL34 Fault Code: Causes, Fixes & Repair Costs

What does the Vokera AL34 fault code mean?

AL34 is a lockout fault on Vokera boilers, particularly the Mynute VHE series, indicating that the control board is not receiving a valid speed signal from the boiler fan. The fan contains a small tachometer (tacho) sensor that continuously reports its rotational speed back to the PCB. If that signal is absent, too weak, or outside the expected range — whether because the fan is stationary, spinning too slowly, or the signal wire is damaged — the boiler locks out as a safety measure. Because the fan is responsible for expelling combustion gases safely through the flue, the boiler will not attempt to fire without confirmation that it is working correctly.

Lockout — engineer likely May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Note down the fault code before doing anything else DIY safe

    Take a photo of the display showing AL34 or write it down. If the fault recurs after a reset, having a record helps the engineer diagnose the issue faster and may indicate whether it is an intermittent or permanent failure.

  2. Check that the gas supply to the boiler is on DIY safe

    Confirm that the gas isolation valve on the supply pipe to the boiler is in the open position (handle in line with the pipe). Check that other gas appliances in the property, such as the hob, are working normally. If no gas appliances are working, contact your gas supplier rather than resetting the boiler.

  3. Attempt a single boiler reset DIY safe

    Press and hold the reset button (labelled R on most Vokera models) for approximately 3–5 seconds until the fault code stops flashing, then release. Allow the boiler a full minute to complete its start-up sequence. If it fires successfully and runs without returning AL34, monitor it over the next 24 hours. Do not reset the boiler more than two or three times in total — repeated unsuccessful resets will not fix the underlying problem and can mask important diagnostic information.

  4. If the fault returns, do not attempt further resets — contact a Gas Safe engineer Gas Safe engineer

    AL34 requires hands-on investigation of the fan, its wiring, and potentially the PCB. These components sit within the boiler's sealed casing alongside the gas train and heat exchanger. A Gas Safe registered engineer will remove the fan, test the motor windings with a multimeter, inspect the tacho signal wire continuity, and check the air pressure switch. If the fan is confirmed faulty it will almost always need replacing rather than repairing, as labour costs make repair uneconomical.

  5. Engineer to inspect and test the fan assembly Gas Safe engineer

    The engineer will spin the fan by hand to feel for bearing roughness, measure motor resistance across the windings, and verify that the tacho output voltage is within specification under power. A seized or electrically failed fan will be replaced like-for-like with a compatible Vokera part or an approved equivalent.

  6. Engineer to check tacho wiring and PCB signal integrity Gas Safe engineer

    Using a multimeter the engineer will trace the signal wire from the fan connector to the PCB, looking for breaks, high resistance joints, or damaged insulation. If the wiring is intact and the new fan still produces AL34, the PCB may need to be tested or replaced.

  7. Engineer to inspect for system blockages if overheat-related faults are also present Gas Safe engineer

    AL34 sits alongside other lockout codes in the Vokera fault hierarchy. If there are signs of overheating — such as AL10, AL20, or AL21 also appearing — the engineer should check that the circulating pump is running freely, that thermostats and thermistors are reading correctly, and that there are no significant blockages in the system pipework.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £220–£350, depending on the underlying cause.

Frequently asked questions

Can I fix Vokera AL34 myself?

The safe DIY actions are limited to resetting the boiler once or twice and noting whether the fault clears. The fan, its wiring, and the PCB are all inside the boiler casing alongside gas components, so any further investigation must be done by a Gas Safe registered engineer. Attempting to work on the fan yourself could invalidate your boiler warranty and, if gas pipework is disturbed, create a serious safety hazard.

How much does it cost to fix AL34 on a Vokera boiler?

For the majority of AL34 faults the repair is a fan replacement. Parts typically cost £100–£150 for a compatible fan, and most Gas Safe engineers charge £100–£200 in labour depending on location and how straightforward the job is, giving a common all-in cost of roughly £220–£350. If the fault turns out to be a faulty PCB rather than the fan, PCB replacement can add another £180–£250 in parts on top of labour, pushing the total higher. If your Vokera is more than 10 years old it is worth weighing repair costs against the price of a new boiler.

Why does my Vokera boiler keep showing AL34 after I reset it?

If AL34 comes back every time you reset, the underlying hardware fault has not been fixed — the reset simply clears the lockout temporarily. Worn fan bearings in particular can allow the fan to start occasionally but fail once the motor warms up, causing the fault to return within minutes or hours. Persistent recurrence means a Gas Safe engineer needs to carry out a proper diagnosis rather than relying on further resets.

Is AL34 dangerous — do I need to stop using the boiler immediately?

Yes, you should stop attempting to use the boiler until it has been inspected. The fan's job is to push combustion gases, including carbon monoxide, safely out through the flue. If the fan is not operating correctly, continuing to fire the boiler risks incomplete combustion or flue gas spillage into the property. The boiler's own safety system has already locked it out for this reason. Make sure you have a working carbon monoxide alarm in the property and keep it in place while the boiler is off.

Affected models: Vokera Mynute VHE, Vokera Mynute, Vokera Unica, Vokera Linea ONE, Vokera Vision

Last reviewed 8 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Vokera AL34 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →