Vokera AL60 Fault Code: Causes, Fixes & Repair Costs

What does the Vokera AL60 fault code mean?

The AL60 code on a Vokèra boiler indicates a jumper tag fault. A jumper tag (also known as a configuration link) is a small connector or resistor mounted on the boiler's PCB (printed circuit board) that communicates essential configuration information to the control system — such as the boiler's output rating and model-specific operating parameters. When the PCB cannot read this tag correctly, whether because it is missing, damaged, or unreadable, the boiler treats this as a safety-critical condition, locks out, and displays AL60. This is classed as a 'Final' alarm, meaning the boiler will not restart on its own and requires investigation before normal operation can resume. AL60 is documented in the Vokèra Mynute VHE Series service manual and may appear on other Vokèra models sharing the same control platform.

Lockout — engineer likely May need a Gas Safe engineer 4 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the boiler's gas supply DIY safe

    Before doing anything else, confirm that other gas appliances in your home (hob, fire) are working normally. If there is no gas supply to the property, contact your gas supplier rather than attempting a boiler reset.

  2. Attempt a single boiler reset DIY safe

    On most Vokèra models, press and hold the reset button (marked 'R') for around 3–5 seconds until the fault code stops flashing, then release and allow the boiler to restart. On dial-operated models, turn the selector to the reset or OFF/RESET position and hold briefly. If the boiler fires up and runs normally, monitor it over the next few hours. Do not attempt more than two or three resets in total — repeated resetting without identifying the underlying cause can mask a genuine fault.

  3. Note whether the fault reappears DIY safe

    If AL60 clears but returns within a short period, or if it does not clear at all, the underlying cause needs to be investigated by a qualified engineer. Make a note of when the code first appeared and whether any recent boiler work was carried out — this will help the engineer diagnose the problem more quickly.

  4. Arrange inspection of the jumper tag by a Gas Safe engineer Gas Safe engineer

    An engineer will need to open the boiler casing and examine the PCB to confirm whether the jumper tag is present, correctly seated, and free from corrosion or damage. This work involves accessing internal electrical components and must only be carried out by a Gas Safe registered engineer.

  5. Replace the jumper tag if missing or damaged Gas Safe engineer

    If the tag is found to be faulty, the engineer will source and fit the correct model-specific replacement. Jumper tags are low-cost components, so if this is the sole cause, the overall repair bill should be modest — primarily covering labour and call-out.

  6. PCB inspection and replacement if the fault persists Gas Safe engineer

    Should the jumper tag be intact but AL60 continue to appear, the PCB itself is likely at fault and will need to be tested and potentially replaced. PCB replacement is a more significant cost; see the FAQs below for guidance on whether repair still makes sense for older Vokèra boilers.

  7. Call a Gas Safe registered engineer Gas Safe engineer

    If you have not already done so, contact a Gas Safe registered engineer to diagnose and resolve the fault. You can verify an engineer's registration at gassaferegister.co.uk. Vokèra's own service line can be reached on 0344 391 0999 if you prefer a manufacturer-backed repair.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£280, depending on the underlying cause.

Frequently asked questions

Can I fix the Vokèra AL60 fault myself?

The reset is the only step a homeowner can safely carry out. Beyond that, resolving AL60 requires opening the boiler casing and inspecting or replacing components on the PCB — work that must be performed by a Gas Safe registered engineer. Attempting it yourself risks further damage and may invalidate any remaining warranty.

How much does it cost to fix a Vokèra AL60 fault in the UK?

If the cause is simply a missing or damaged jumper tag, you are typically looking at £100–£280 once call-out, labour, and the low-cost part are combined. If the PCB has failed, the part alone can cost £300–£500 depending on the model, pushing the total repair bill considerably higher. For an older Vokèra boiler already showing multiple fault codes, it is worth getting a quote for a new boiler alongside the repair quote before committing.

Should I repair or replace my Vokèra boiler if it needs a new PCB?

If the boiler is under ten years old and otherwise in good condition, a PCB replacement can be worthwhile. On a boiler over twelve to fifteen years old — particularly one that has locked out on multiple occasions — the cost of a new PCB may be difficult to justify given that other components are likely to fail soon as well. A Gas Safe engineer will be able to give you an honest assessment, and many boiler installers will provide a free replacement quote at the same time.

Why did AL60 appear after my boiler was serviced?

AL60 appearing shortly after a service is a strong clue that the jumper tag was accidentally disturbed during the work. Engineers sometimes need to move or remove components near the PCB, and the tag can be dislodged without anyone noticing at the time. Contact the engineer who carried out the service and explain what has happened — they should return to investigate and rectify it.

Affected models: Vokèra Mynute VHE Series, Vokèra Mynute, Vokèra Linea, Vokèra Unica

Last reviewed 8 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Vokera AL60 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →