VVokera logo

Vokera E060 Fault Code: Causes, Fixes & Repair Costs

What does the Vokera E060 fault code mean?

The E060 code appears on Vokera boilers when the control board cannot obtain a reliable temperature reading from the domestic hot water (DHW) probe — also known as a thermistor. This small sensor continuously monitors the temperature of your hot water supply by measuring changes in its electrical resistance; as water heats up, resistance drops, and those readings are fed back to the PCB to regulate output. When the signal falls outside expected parameters — due to a failing sensor, damaged wiring, or a PCB issue — the boiler flags E060 and may display fluctuating hot water temperatures or refuse to produce hot water altogether.

Engineer may be needed May need a Gas Safe engineer 6 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Reset the boiler DIY safe

    Press and hold the reset button (labelled R on most Vokera models) for 3–5 seconds until the fault code stops flashing, then release and allow the boiler to restart. On dial-control models, turn the selector to the reset or OFF/RESET position and hold briefly. If hot water returns and the code does not come back, monitor the boiler over the next day or two. Avoid resetting more than 2–3 times — repeated resets without a fix are not a solution.

  2. Check that your gas supply is active DIY safe

    Confirm that other gas appliances in your home — such as a hob or gas fire — are working normally. If they are not, contact your gas supplier rather than resetting the boiler further.

  3. Call a Gas Safe registered engineer to inspect the DHW probe and wiring Gas Safe engineer

    A qualified engineer will locate the DHW thermistor, check for loose terminals, and use a multimeter to measure the probe's resistance across a range of temperatures. A reading that falls outside the manufacturer's specification confirms the sensor has failed and needs replacing. This is a straightforward job and the most common resolution for E060.

  4. Engineer to test and replace the DHW thermistor if required Gas Safe engineer

    Compatible NTC temperature sensors for Vokera boilers are widely available from heating spares suppliers. The engineer will fit a replacement probe, clear the fault code, and verify that hot water temperature control has returned to normal before leaving.

  5. Engineer to inspect the PCB if the fault persists after sensor replacement Gas Safe engineer

    If E060 reappears with a new probe installed, the PCB input channel handling the DHW sensor signal may be faulty. The engineer will test the board and advise on repair or replacement. PCB work is always engineer-only territory and represents a more significant repair cost.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £100–£250, depending on the underlying cause.

Frequently asked questions

Can I fix the Vokera E060 fault myself?

The only homeowner-safe step is a boiler reset — press and hold the reset button for 3–5 seconds. If the code clears and hot water works normally, you may be fine. If E060 comes back, the probe, wiring, or PCB needs professional testing. Probes are internal components that require a Gas Safe registered engineer to access, test with a multimeter, and replace safely.

How much does it cost to fix a Vokera E060 fault?

For a straightforward DHW probe replacement you should typically expect to pay between £100 and £250 all-in, covering the call-out charge, labour, and the part itself (which is inexpensive — usually £15–£30). If the PCB turns out to be the root cause, costs rise significantly; a replacement PCB for a Vokera boiler commonly runs £180–£400 for the part alone, so total costs including labour could reach £350–£500 or more. Vokera also offer a fixed-price repair service that covers call-out, labour, and parts under warranty.

Will E060 stop my boiler heating my home as well as hot water?

E060 is specifically a domestic hot water probe fault, so central heating is often unaffected. Many homeowners notice the boiler continues to heat radiators normally but struggles to deliver consistent hot water temperatures or stops producing hot water altogether. That said, if the fault is severe enough the boiler may lock out entirely, so it is worth getting it looked at promptly.

How do I find a Gas Safe engineer to repair my Vokera boiler?

You can search for registered engineers in your area at gassaferegister.co.uk — the official UK authority for gas safety. Always ask to see an engineer's Gas Safe ID card before allowing work to start. Some engineers specialise in Vokera boilers, which can be worth asking about when booking, particularly if the repair may involve a PCB.

Affected models: Vokera Unica, Vokera Mynute, Vokera Easi-Heat, Vokera Vision, Vokera Linea, Vokera Ion

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Vokera E060 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →