Worcester Bosch F0 242 Fault Code: Causes, Fixes & Repair Costs

What does the Worcester Bosch F0 242 fault code mean?

The F0 242 fault code on a Worcester Bosch boiler signals a problem with the burner control unit — known as the KIM. When this code appears, the boiler has detected an issue with the KIM's wiring or its operating characteristics, and in some cases the main PCB may also be involved. The boiler will typically lock out, cutting off heating and hot water, and you'll usually see the fault indicator LED flashing alongside the RESET button. The F0 prefix covers a family of internal component faults; sub-codes in the range F0 242 through F0 272 all point specifically to the burner control unit as the source of the problem. Sub-code 242 is the most commonly reported, but if your display shows anything from 243 to 272 alongside F0, the diagnosis and repair path are essentially the same: the KIM wiring and operation need professional inspection, and replacement of the unit may be required.

Lockout — engineer likely May need a Gas Safe engineer 8 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Note the exact code on the display and any symptoms DIY safe

    Write down the full code as shown — for example 'F0 242' — and record whether heating, hot water, or both have stopped. Note if there was a recent power cut or electrical storm. This information will help your engineer understand the fault history and potentially speed up diagnosis.

  2. Attempt a single reset DIY safe

    Press and hold the boiler's reset button for around three seconds, then release. If the fault clears, monitor the boiler closely. If F0 242 reappears, do not keep resetting — repeated resets will not fix an underlying component fault and may mask useful diagnostic information. Two to three attempts is the absolute maximum.

  3. Do not remove the boiler casing or inspect internal components Gas Safe engineer

    Internal checks on the KIM, PCB, wiring looms, or any other electronic component must only be carried out by a Gas Safe registered engineer. Opening the casing yourself is unsafe, could void any remaining warranty, and is not permitted for gas appliances under UK regulations.

  4. Call a Gas Safe registered engineer to diagnose and repair the fault Gas Safe engineer

    An engineer will test the KIM wiring and plug connections, verify the unit's operating characteristics, and replace the burner control unit if testing confirms it has failed. They will also inspect the PCB for any associated damage. This is not a fault that resolves without professional intervention.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£380, depending on the underlying cause.

Frequently asked questions

Can I reset a Worcester Bosch F0 242 fault myself?

Yes, one reset is worth trying — hold the reset button for about three seconds. If the code disappears and stays away, an electrical glitch may have been the cause. However, if F0 242 comes back, stop resetting and book an engineer. Repeatedly resetting the boiler will not fix a faulty KIM or PCB, and it can make diagnosis harder.

What is the burner control unit (KIM) and how much does it cost to replace?

The KIM is a dedicated electronic module that controls the ignition sequence and burner operation. It sits separately from the main PCB. Having a Gas Safe engineer supply and fit a replacement KIM typically costs in the region of £150–£350 depending on the specific boiler model, parts availability, and your location. Labour alone is usually £80–£120 on top of the part price.

My boiler is showing F0 243 (or another number between 243 and 272) — is that the same fault?

Yes. Sub-codes F0 242 through F0 272 all relate to the burner control unit. The exact sub-code indicates a slightly different condition detected within the KIM, but the diagnosis and repair process are the same across the whole range: the engineer will check the KIM wiring and operating characteristics and replace the unit if necessary.

Could a PCB replacement be needed, and is it worth the cost on an older boiler?

A PCB replacement is occasionally required alongside or instead of the KIM, particularly if a power surge has caused wider damage. PCB replacement typically costs £450–£700 including parts and labour, which is significantly more than a KIM swap. If your boiler is over 10 years old or out of manufacturer warranty, it is worth getting a quote for a new boiler at the same time — modern A-rated condensing boilers are considerably more efficient and the long-term running cost savings can outweigh the upfront investment.

Affected models: Worcester Bosch Greenstar 25i, Worcester Bosch Greenstar 30i, Worcester Bosch Greenstar 40i, Worcester Bosch Greenstar 25Si, Worcester Bosch Greenstar 30Si, Worcester Bosch Greenstar 8000 Style, Worcester Bosch Greenstar 4000, Worcester Bosch Greenstar CDi Classic

Last reviewed 2 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Worcester Bosch F0 242 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →