Alpha Red A and B Illuminated Fault Code: Causes, Fixes & Repair Costs

What does the Alpha Red A and B Illuminated fault code mean?

When both the A and B indicator lights on your Alpha boiler are illuminated continuously in solid red, the boiler is telling you that the burner has failed to light. The boiler has locked out as a safety measure and will not attempt to fire again until the fault is cleared. It is worth noting that the A and B lights can display several different patterns, each with a different meaning: both lights flashing alternately points to low system pressure; both flashing simultaneously suggests a blocked flue or fan fault; A flashing with B illuminated indicates a pump or restricted flow issue. This page focuses specifically on both A and B lit continuously and solidly — the burner ignition lockout.

Lockout — engineer likely May need a Gas Safe engineer 7 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check that your gas supply is working DIY safe

    Turn on another gas appliance in your home — a gas hob or gas fire, for example. If those work normally, the supply to your property is fine. If nothing gas-powered works, contact your gas supplier or call the National Gas Emergency Service on 0800 111 999 immediately.

  2. Reset the boiler DIY safe

    On Alpha boilers, turn the selector switch to the reset position (marked as position 3 on many models) and hold it there. The boiler will pause for approximately 25–30 seconds before attempting to restart the ignition sequence. You can attempt a reset two or three times, but do not reset repeatedly if the boiler keeps locking out — this can mask a more serious fault.

  3. Check the system pressure DIY safe

    Look at the pressure gauge on the boiler. It should read between 1 and 1.5 bar when the system is cold. If it is below 1 bar, the boiler may not fire. Use the filling loop — usually a braided metal hose with one or two valves beneath the boiler — to top up the pressure. Open the valve(s) slowly, watch the gauge rise to around 1.2–1.5 bar, then close the valve(s) firmly. Note: if the A and B lights are flashing alternately rather than both lit solidly, low pressure is the likely culprit.

  4. Check for a frozen condensate pipe in cold weather DIY safe

    If temperatures have dropped below freezing and the boiler's condensate pipe runs outside or through an unheated space, it may have frozen. You can thaw it by pouring warm (not boiling) water over the external section of the pipe, starting at the outlet end and working back towards the boiler. Once cleared, reset the boiler as described above.

  5. Call a Gas Safe registered engineer Gas Safe engineer

    If the boiler continues to lock out after a reset, or if you cannot identify a simple cause such as low pressure or a frozen condensate pipe, the fault requires professional diagnosis. A Gas Safe engineer will inspect the ignition electrode, burner, gas valve, flame sensor, and flue to identify and resolve the root cause. Do not attempt to open the boiler casing or work on any gas components yourself — this is illegal without Gas Safe registration and is extremely dangerous.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£350, depending on the underlying cause.

Frequently asked questions

Can I just keep resetting my Alpha boiler when the red A and B lights come on?

You can try a reset two or three times, but repeatedly resetting a boiler that keeps locking out is not a solution and can sometimes make diagnosis harder. If the boiler relights and runs normally after a single reset, monitor it closely. If the fault returns within a short time, or if the boiler fails to light at all after resetting, you need a Gas Safe engineer to investigate the underlying cause.

What is the difference between the A and B lights flashing and being lit solidly?

The pattern of the A and B indicator lights matters. Both lit continuously and solidly means the burner has failed to light — which is what this page covers. Both flashing alternately usually indicates low system pressure, which you can often resolve yourself by topping up via the filling loop. Both flashing simultaneously points to a flue blockage or fan issue. A flashing with B solid suggests a pump or flow problem. Always note the exact pattern before calling an engineer, as it helps with diagnosis.

How much does it typically cost to fix this fault on an Alpha boiler in the UK?

For the most common causes — ignition electrode replacement, flame sensor, or a burner clean — most people pay between £120 and £350 including parts and labour. A gas valve replacement tends to sit toward the higher end of that range. More complex repairs such as a PCB replacement can cost more, and a heat exchanger failure — which is rare but possible — can run to £400–£600, at which point it is worth comparing the repair cost against a new boiler installation, particularly if your boiler is more than ten years old.

Is it safe to use my boiler while it is showing this fault?

No. When the A and B lights are illuminated solidly, the boiler has locked out and is not operating — so there is no immediate danger from the boiler running unsafely. However, you should not attempt to force the boiler to run by repeated resets if it is consistently failing to light. Leave diagnosis and repair to a Gas Safe registered engineer.

Affected models: Alpha CD25X, Alpha CD28X, Alpha CB24, Alpha CB28, Alpha E-Tec, Alpha E-Tec Plus, Alpha InTec

Last reviewed 2 July 2026 · verified by our team.