Alpha Red A Red B Alternating Fault Code: Causes, Fixes & Repair Costs

What does the Alpha Red A Red B Alternating fault code mean?

When the A and B indicator lights on your Alpha boiler flash alternately — each one lighting up in turn — the boiler is telling you that system pressure has dropped too low for safe operation. You will typically see the pressure gauge sitting below 1 bar, outside the green zone. The boiler shuts down to protect itself until pressure is restored to the correct level (between 1.0 and 1.5 bar). This is one of the most straightforward fault indicators on Alpha boilers and, in many cases, can be resolved by the homeowner without any tools. Note: do not confuse this with a red A light flashing alongside a steady yellow B light, which signals a burner ignition failure — that is a separate fault requiring an engineer.

Engineer may be needed Some DIY checks possible 6 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the pressure gauge on the boiler DIY safe

    Look at the pressure gauge (either a dial or a digital reading on the display). If it reads below 1 bar the low-pressure diagnosis is confirmed. Make a note of the reading before you do anything else — this gives you a baseline.

  2. Locate the filling loop and repressurise the system DIY safe

    The filling loop on most Alpha boilers is a short braided flexible hose with one or two valves, usually found beneath the boiler casing or inside a cupboard on the pipework. Slowly open the valve(s) by turning a quarter-turn and watch the gauge rise. Stop when the needle reaches 1.2–1.5 bar (in the green zone). Close the valve(s) fully. Do not overfill — if the pressure goes above 1.5 bar, bleed a small amount of water from a radiator bleed valve until it drops back into range.

  3. Reset the boiler DIY safe

    Once pressure is back in the green zone, reset the boiler by rotating the selector dial to the RESET position. Hold it there for approximately 30 seconds, then return the dial to your normal heating or hot water setting. The alternating lights should stop and the boiler should fire up normally.

  4. Monitor the pressure over the next few days DIY safe

    Check the gauge daily for four or five days. If pressure holds steady above 1 bar, the issue was simply gradual seepage or a recent radiator bleed. If it drops again within a week or two, there is an underlying problem that needs professional investigation — do not simply keep topping up without finding the cause.

  5. Inspect visible pipework, radiator valves, and underneath the boiler for leaks DIY safe

    Run your hand along accessible pipework and around the base of radiators to feel for damp. Look for mineral staining (white or brown deposits) around joints, which indicates that water has been escaping and evaporating. Check the condensate pipe and its connections too. Report any findings to the engineer.

  6. Call a Gas Safe registered engineer to diagnose recurring pressure loss Gas Safe engineer

    If the pressure drops repeatedly, or if you found any signs of a leak during your inspection, you need a Gas Safe registered engineer. They will pressure-test the system, check the expansion vessel pre-charge pressure, inspect the PRV, and trace any hidden leaks. Do not continue to top up the system without finding the root cause — persistent low pressure can eventually damage the pump and heat exchanger.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £80–£320, depending on the underlying cause.

Frequently asked questions

Can I repressurise my Alpha boiler myself to fix the Red A Red B fault?

Yes — repressurising is explicitly described in Alpha's own user manuals as a homeowner task. Locate the filling loop beneath the boiler, open the valve(s) until the gauge reaches 1.0–1.5 bar, then close the valve and reset the boiler. If you are comfortable following those steps there is no need to call an engineer for a one-off pressure drop. However, if the pressure falls again within a short time, that points to a leak or a failing expansion vessel and you should get a Gas Safe engineer to investigate rather than keep topping up.

Why does my Alpha boiler keep losing pressure even after I top it up?

Recurring pressure loss usually means one of three things: a slow leak somewhere on the system (often at a radiator valve, a compression fitting, or the boiler's own connections), a weeping pressure relief valve that is releasing water through the discharge pipe, or a waterlogged expansion vessel that can no longer compensate for normal pressure fluctuations. A Gas Safe engineer can pressure-test the system, recharge or replace the expansion vessel, and replace a faulty PRV. Continuing to top up without fixing the root cause can mask a worsening leak and risk longer-term damage to the pump.

How much does it cost to fix the cause of low boiler pressure in the UK?

If a single top-up solves the problem, the fix is free. For a professional repair, costs depend on what is wrong: replacing or recharging an expansion vessel typically runs £150–£250 including labour; replacing a pressure relief valve is usually £80–£180; tracing and repairing a system leak generally costs £150–£350 depending on where the leak is and how accessible the pipework is. Very large jobs such as a corroded heat exchanger can cost considerably more, but those are rarely the cause of straightforward low-pressure faults — mention any concerns about big-ticket components to your engineer before they start work.

What is the correct pressure for an Alpha boiler when cold?

Alpha recommends a cold-system pressure of 1.0–1.5 bar, shown in the green zone on the pressure gauge. When the system is fully up to operating temperature the pressure will rise slightly — typically to around 1.5–2.0 bar — which is normal. If the gauge reads above 2.5 bar when cold, or if the PRV discharge pipe is dripping, the system may be overpressurised and you should call an engineer rather than adding more water.

Affected models: Alpha CB24, Alpha CB28, Alpha CD25X, Alpha CD28X, Alpha E-Tec Plus, Alpha E-Tec

Last reviewed 2 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →