AAndrews logo

Andrews A03 Fault Code: Causes, Fixes & Repair Costs

What does the Andrews A03 fault code mean?

The A03 fault code on Andrews boilers (including Andrews Water Heaters commercial units) signals a protective lockout, most commonly triggered by one of three underlying issues: overtemperature protection activating when the flow temperature climbs too high, a fan fault where the flue-gas extraction fan is not running correctly, or in some model variants, an ignition failure. Because Andrews produces a range of commercial and domestic hot water appliances — many sharing control platforms with Ariston and Vokera-derived systems — the precise trigger can differ between models. In all cases the boiler or water heater shuts itself down as a safety measure. Do not attempt to override this lockout; the cause must be identified and corrected before normal operation can resume.

Lockout — engineer likely May need a Gas Safe engineer 4 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check the system pressure gauge DIY safe

    Look at the pressure gauge on the appliance or boiler panel. On a sealed central heating system it should read between 1 and 1.5 bar when cold. If it reads below 1 bar, low pressure may be contributing to the fault. Refer to your boiler's user manual for instructions on using the filling loop to bring pressure back up to approximately 1.2 bar, then attempt a single reset.

  2. Bleed radiators and purge air from the system DIY safe

    Using a radiator bleed key, open each radiator bleed valve in turn (starting from the ground floor) until water runs steadily with no air sputtering out. Recheck system pressure afterwards and top up if it has dropped. This removes trapped air that can cause localised overheating and trigger the A03 protection.

  3. Check the flue terminal is unobstructed DIY safe

    Go outside and visually inspect the flue outlet. Make sure it is not blocked by debris, bird nesting material, or — in cold weather — a build-up of ice. Do not probe inside the flue or touch any components; this is a visual check only. A blocked terminal restricts draught, loads the fan, and can contribute to an A03 lockout.

  4. Attempt a single boiler reset DIY safe

    Once pressure has been checked and the system bled, press and hold the reset button as described in your user manual. Allow the appliance to complete its full start-up sequence before deciding whether the fault has cleared. If the A03 code returns immediately, do not keep resetting — repeated resets without fixing the underlying cause will not help and may worsen the situation.

  5. Engineer to inspect and test the fan assembly Gas Safe engineer

    A Gas Safe registered engineer will check fan speed against the manufacturer's specification, inspect motor windings and bearings, look for mechanical obstructions within the fan housing, and verify that all electrical connectors to the fan harness are secure and corrosion-free. A faulty fan must be replaced like-for-like; this is not a DIY task on a gas appliance.

  6. Engineer to test the temperature sensors and high-limit thermostat Gas Safe engineer

    The engineer will use a multimeter to check NTC resistance values against the temperature–resistance curve for the specific sensor fitted, confirm the sensor is correctly seated in its pocket, and inspect wiring for damage or corrosion. A defective high-limit thermostat will be replaced at this stage.

  7. Engineer to check the circulation pump and system flow rate Gas Safe engineer

    The pump will be tested for correct rotation, adequate flow rate, and signs of seizure or sludge ingress. If the system has not been chemically flushed recently, the engineer may recommend a power flush to clear magnetite and scale that could be restricting flow.

  8. Engineer to inspect the gas valve and ignition components (where A03 relates to ignition) Gas Safe engineer

    If the model variant is displaying A03 as an ignition lockout, the gas valve, igniter electrode, and flame-sense electrode will all be examined. The engineer will confirm correct gas supply pressure and that the valve opens and closes as commanded by the PCB.

  9. Engineer to test or replace the PCB if all other components pass Gas Safe engineer

    If the fan, sensors, pump, and gas valve all prove serviceable, the PCB becomes the suspect. The engineer may run a diagnostic routine, swap the board for a tested unit, or arrange a manufacturer warranty repair depending on the appliance's age and service history.

  10. Call a Gas Safe registered engineer if the fault persists or you cannot identify the cause Gas Safe engineer

    Andrews commercial appliances and domestic water heaters should be serviced by a Gas Safe registered engineer experienced with commercial equipment. Contact Andrews (Baxi Commercial) technical support or your regular heating engineer. Do not continue operating an appliance that keeps locking out on A03 — it is shutting down for a safety reason.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£450, depending on the underlying cause.

Frequently asked questions

Is the Andrews A03 fault code always the same fault, or does it vary by model?

It can vary. On Andrews appliances sharing an Ariston-derived platform the A03 code typically signals an overtemperature lockout, meaning the flow temperature has exceeded a safe threshold. On units built on Vokera-related control systems it most commonly points to a fan fault. Some variants use A03 for ignition failures. Check your specific model's user manual or contact Andrews (Baxi Commercial) technical support with your appliance serial number to confirm the exact meaning before any repair work is carried out.

Can I fix the Andrews A03 fault myself?

There are a few checks a homeowner can safely carry out: verify the system pressure is between 1 and 1.5 bar, bleed the radiators to remove trapped air, and visually inspect the flue terminal for blockages. One reset attempt after these checks is reasonable. However, any work involving the fan, sensors, pump, gas valve, or PCB must be carried out by a Gas Safe registered engineer. On commercial Andrews water heaters, even routine fault diagnosis is best left to a qualified specialist.

How much does it cost to repair an Andrews boiler showing A03?

For the most common repairs — fan replacement or sensor and thermostat work — most UK homeowners pay between £150 and £450 including parts and labour. A straightforward sensor swap typically sits at the lower end; a fan replacement usually falls in the £200–£350 range. If the PCB turns out to be faulty, costs can rise to £400–£600 or more depending on the model, as commercial-grade boards tend to be more expensive than domestic equivalents. If two major components need replacing simultaneously it is worth obtaining a quote for a new or refurbished appliance for comparison.

Why does the Andrews A03 fault keep coming back after a reset?

A reset does not fix the underlying problem — it simply clears the lockout condition so the appliance can attempt to start again. If A03 returns quickly or repeatedly, it means the root cause (overheating, fan degradation, a failing sensor, or another issue) is still present. Repeated resets without a repair can mask a developing fault and, in some cases, cause the boiler to go into a deeper lockout state. Book a Gas Safe engineer to diagnose and resolve the fault properly rather than relying on resets.

Affected models: Andrews WH series commercial water heaters, Andrews WHi condensing range, Andrews EVO range, Andrews packaged units (Baxi Commercial platform)

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Andrews A03 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →