Andrews A05 Fault Code: Causes, Fixes & Repair Costs

What does the Andrews A05 fault code mean?

The A05 code indicates that the boiler or water heater has shut itself down because it cannot confirm the combustion fan is running correctly. The fan is responsible for expelling harmful flue gases safely out of the appliance — without a confirmed fan signal, the unit will refuse to fire as a safety precaution. This lockout protects against dangerous gases building up inside the property. The fault may point to a failed fan motor, a wiring issue between the fan and the control board, a blocked flue or condensate pipe, a faulty air pressure switch, or in some cases a PCB fault mimicking fan failure.

Lockout — engineer likely May need a Gas Safe engineer 4 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check your gas supply is live DIY safe

    Make sure other gas appliances in the property (hob, gas fire) are working normally. If there is no gas supply to the house, contact your gas supplier before doing anything else. A loss of gas pressure can sometimes prevent the fan sequence from completing.

  2. Look and listen when the unit tries to start DIY safe

    Stand near the appliance and attempt a restart. You should hear the fan spin up — a low hum or whirr — before ignition is attempted. If you hear nothing, or the fan sounds laboured or intermittent, that points strongly to a fan or wiring problem. Note what you observe to report to the engineer.

  3. Inspect the flue terminal for obvious blockages DIY safe

    Go outside and look at where the flue exits the building. Check for visible obstructions such as leaves, a bird's nest, ice, or a damaged terminal cap. Do not attempt to dismantle any flue pipework — simply note and photograph any obstruction. A clear external terminal is a good sign; if blocked, call an engineer to clear it safely.

  4. Thaw a frozen condensate pipe if cold weather is a factor DIY safe

    In freezing temperatures the condensate pipe — usually a white plastic pipe running from the boiler to an external drain — can ice up and cause safety shutdowns. You can carefully pour warm (not boiling) water over the visible external section or wrap it with a warm damp cloth to thaw it. Once thawed, reset the boiler. Insulating the pipe with foam lagging helps prevent a recurrence.

  5. Reset the boiler (up to two or three times) DIY safe

    Press and hold the reset button as described in your Andrews appliance manual. Wait for the startup sequence to complete. If the A05 code clears and the unit runs normally, monitor it over the next hour. If the fault returns or does not clear after two or three reset attempts, stop resetting — repeated failed ignitions can cause other issues — and move on to calling an engineer.

  6. Call a Gas Safe registered engineer to diagnose and repair the fault Gas Safe engineer

    If the fault persists after the checks above, the repair requires a qualified professional. The engineer will test the fan motor speed and operation, check the wiring harness for continuity and connection quality, test the air pressure switch with a multimeter, inspect the flue and condensate system internally, and test the PCB fan-signal outputs. Do not attempt to open the casing, touch internal wiring, or handle any components yourself.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£375, depending on the underlying cause.

Frequently asked questions

Is the Andrews A05 code dangerous — should I keep using the appliance?

The boiler or water heater will have locked itself out, so it will not fire while the fault is active. That means there is no immediate risk of carbon monoxide from combustion, but you also have no hot water or heating. Do not attempt to bypass the lockout or force the unit to run — the fan lockout exists precisely to prevent unsafe venting of flue gases. Get the fault diagnosed promptly.

Can I fix the Andrews A05 fault myself?

A few homeowner-safe checks are worthwhile: confirming the gas supply is on, listening for fan noise on startup, inspecting the external flue terminal for blockages, thawing a frozen condensate pipe in cold weather, and attempting a reset up to two or three times. Beyond that, opening the casing or touching internal components requires a Gas Safe registered engineer. Fan motors, wiring harnesses, air pressure switches, and PCBs must all be worked on by a qualified professional.

How much does it cost to fix an A05 fan fault on an Andrews appliance?

For the most common repair — replacing the fan motor — expect to pay roughly £150 to £375 including parts and labour, depending on the specific Andrews model and your location. An air pressure switch swap typically costs £100 to £180 all in. If the PCB turns out to be the culprit, parts alone can run to £250 to £400 or more, making it a significantly pricier repair — worth mentioning to your engineer before authorising the work so you can weigh it against the age of the appliance.

Why does the A05 code keep coming back after I reset it?

A fault that clears on reset but returns within hours or days usually means an underlying component is failing intermittently — most often a fan motor with worn bearings, a loose wiring connector that vibrates back into contact, or an air pressure switch that is borderline functional. Each reset without a proper repair simply delays the inevitable and can mask a worsening fault. Book a Gas Safe engineer to carry out a proper diagnostic rather than continuing to reset.

Affected models: Andrews ECOflo, Andrews CLASSICflo, Andrews MAXXflo, Andrews commercial water heaters (various)

Last reviewed 1 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Andrews A05 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →