Andrews E29 Fault Code: Causes, Fixes & Repair Costs

What does the Andrews E29 fault code mean?

The E29 code on an Andrews boiler indicates a flame-loss lockout. Unlike a fault where the boiler fails to ignite in the first place, E29 means the boiler successfully established a flame but then lost it during operation — and has shut itself down as a safety measure. The control system detected that a safe, stable flame could not be maintained, so it locked out rather than continuing to attempt ignition. This is normal protective behaviour; the boiler is doing exactly what it should. The fault needs to be investigated and resolved before the boiler will fire again. Note that the precise trigger can vary between Andrews models (including commercial water heater ranges), so always cross-reference with your specific model's service manual or contact Andrews directly if you are unsure.

Lockout — engineer likely May need a Gas Safe engineer 6 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check that your gas supply is active DIY safe

    Check whether other gas appliances in your home — such as a gas hob or gas fire — are working normally. If nothing gas-powered is working, the issue may be with your meter, a closed isolation valve, or a wider supply interruption. Contact your gas supplier if you suspect a network issue. If gas supply is confirmed as normal, move on to the next step.

  2. Inspect the condensate pipe for freezing (cold weather only) DIY safe

    Locate the white plastic pipe that exits your boiler and runs outside, usually discharging near a drain. If the weather is at or below freezing and the pipe feels solid, it is likely frozen. Gently pour warm — not boiling — water along the frozen section until it clears. Dry the pipe, then attempt a reset. Consider lagging the pipe with foam insulation to prevent a recurrence.

  3. Reset the boiler once DIY safe

    Press and hold the reset button on your Andrews boiler as described in your user guide. Allow the boiler a full ignition attempt — this typically takes 30–60 seconds. If it fires up and runs normally, monitor it over the next few hours. Do not reset more than two or three times in quick succession; repeated resets without resolving the underlying cause can cause further damage and mask the real fault.

  4. Check system pressure if applicable to your model DIY safe

    Some Andrews boilers operate with a sealed system that has a pressure gauge. If the gauge reads below 1 bar, the system may need topping up via the filling loop. Consult your user manual for the correct procedure. Note that not all Andrews appliances use a pressurised system — check whether this applies to your model before proceeding.

  5. Do not attempt to open the boiler casing or inspect internal components Gas Safe engineer

    Internal inspection of the gas valve, burner, ignition electrodes, flame sensor, flue, or PCB must only be carried out by a Gas Safe registered engineer. Removing the casing and working on gas components without the correct qualifications is illegal under UK gas safety regulations and will invalidate your warranty.

  6. Contact a Gas Safe registered engineer to diagnose and repair the fault Gas Safe engineer

    If the boiler has not recovered after the steps above, a qualified engineer needs to attend. They will carry out systematic checks including gas inlet pressure, valve operation, electrode condition and alignment, flame sensor signal, flue integrity, and PCB function. You can verify any engineer's Gas Safe registration at gassaferegister.co.uk before they begin work.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £80–£350, depending on the underlying cause.

Frequently asked questions

Can I reset my Andrews boiler myself when E29 appears?

Yes — a single reset attempt is safe and sensible. Press the reset button and allow the boiler a full ignition cycle. If it lights and runs normally, keep an eye on it over the next day or two. However, if E29 returns after one or two resets, repeated resetting is not advisable. The boiler is locking out for a reason, and masking the fault by continually resetting can cause further component wear. At that point, call a Gas Safe registered engineer.

Is E29 dangerous — do I need to evacuate my home?

The E29 lockout itself means the boiler has already shut down safely, so there is no ongoing combustion risk from the appliance. However, if you smell gas at any point, do not reset the boiler — leave the property immediately, avoid using any switches or flames, and call the National Gas Emergency Service on 0800 111 999. If you have any suspicion of a carbon monoxide leak (symptoms include headaches, dizziness, or nausea), evacuate and call 999.

My Andrews boiler keeps coming back to E29 after being reset — what does that mean?

A recurring E29 lockout almost always points to a component fault rather than a one-off event. The most common culprits are a gas valve that is sticking or failing, a flame sensor that is coated in deposits and needs cleaning or replacing, or — less commonly — a PCB that is not processing the flame signal correctly. A Gas Safe engineer can measure the flame ionisation signal with test equipment to pinpoint which component is at fault. If your boiler is over 12–15 years old and has already had several repairs, it may be worth discussing replacement with your engineer rather than investing further in an ageing appliance.

How much does it typically cost to fix an Andrews E29 fault?

For the most common repairs — cleaning or replacing the flame sensor and electrode — most homeowners pay in the region of £80–£200 including labour. Replacing a gas valve typically adds up to around £250–£350 all-in. These figures cover the majority of E29 faults. In rarer cases where the PCB needs replacing, costs can rise to £400–£600 depending on the model and part availability; if that applies to your situation your engineer will advise you before proceeding.

Affected models: Andrews Super Series, Andrews Meridian, Andrews HS Series, Andrews HWA Series, Andrews WH Series, Andrews commercial water heaters (various)

Last reviewed 16 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Andrews E29 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →