BBaxi logo

Baxi H.02-.04 Fault Code: Causes, Fixes & Repair Costs

What does the Baxi H.02-.04 fault code mean?

The H.02-.04 fault code on Baxi boilers indicates a parameter error — the boiler's control board has either lost, corrupted, or is unable to read its own stored settings. As a safety measure, the boiler shuts down rather than operate with unreliable configuration data. On Baxi 200 and 400 series models this typically appears as a temporary blocking fault labelled as a parameter error, while on newer Baxi 600 and 800 series boilers the same code can reflect the PCB being unable to read its stored settings at all. In either case the boiler will not fire until the underlying cause is resolved. A single reset attempt is always worth trying first, but if the fault returns the issue almost certainly lies with the PCB itself and will require a Gas Safe registered engineer.

Lockout — engineer likely May need a Gas Safe engineer 6 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Reset the boiler once DIY safe

    Locate the reset button on the front panel — on most Baxi models it is marked with a flame symbol or the word 'Reset'. Press and hold it for 3–5 seconds until the boiler attempts to restart. Stand back and allow a full restart cycle (up to two minutes). If the boiler fires up and runs normally, monitor it over the next few hours. Do not reset more than once or twice; repeated resets on a locked-out boiler can mask a more serious issue and will not address the root cause.

  2. Check for an obvious internal leak DIY safe

    While the boiler is not firing, open the front casing panel if it lifts away easily (no tools required on most Baxi models) and look for any signs of dripping water, staining, or corrosion around pipework joints and the pump. Do not touch any wiring or components. If you spot a leak, note its location and report it to your engineer — this is likely the cause of the PCB fault.

  3. Check mains power supply and isolator switch DIY safe

    Make sure the boiler's fused spur or isolator switch is fully on and that there has not been a recent tripped circuit breaker in your consumer unit. A partial or intermittent power supply can corrupt PCB memory. If a breaker has tripped repeatedly, there may be an electrical fault that also requires an electrician.

  4. Engineer to diagnose and reconfigure PCB parameters Gas Safe engineer

    A Gas Safe registered engineer will connect to the boiler's diagnostic interface and check whether the stored parameters match the expected values for your model. In many cases — particularly after a power surge or a previous PCB replacement — the settings simply need to be re-entered or reset to factory defaults. This is the quickest and least expensive resolution and is often completed within a single visit.

  5. Engineer to inspect PCB for physical damage or moisture Gas Safe engineer

    If a parameter reconfiguration does not clear the fault, the engineer will remove and examine the PCB. They will look for burnt tracks, corrosion, swollen capacitors, or cracked solder joints. Moisture damage will also be investigated in the context of any leak found inside the casing. This inspection determines whether repair or full replacement is the appropriate course of action.

  6. Engineer to replace the PCB if necessary Gas Safe engineer

    If the board is found to be faulty beyond reconfiguration, a replacement PCB will be sourced, fitted, and programmed with the correct parameters for your boiler model. This is the most involved and costly resolution but is often the only option when the board's internal memory or circuitry has failed. Always ask your engineer whether a repair (re-soldering, component-level work) is viable before committing to a full board replacement, as this can meaningfully reduce costs.

  7. Contact a Gas Safe registered engineer if the fault persists after your reset attempt Gas Safe engineer

    If the boiler locks out again after your single reset, do not keep cycling the reset button. Call a Gas Safe registered engineer to carry out a full diagnosis. You can find accredited engineers at gassaferegister.co.uk. If your Baxi boiler is within its warranty period and has been serviced annually by a Baxi-accredited installer, this repair may be covered at no cost — check your warranty documents before booking an independent engineer.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£500, depending on the underlying cause.

Frequently asked questions

Can I fix Baxi H.02-.04 myself just by resetting the boiler?

A single reset is always the right first step and occasionally clears the fault if it was triggered by a brief power interruption or transient glitch. However, if the code returns after resetting, the underlying issue — usually a corrupted or failing PCB — cannot be resolved without a Gas Safe registered engineer. Repeated resets will not fix a hardware or configuration problem and may delay proper diagnosis.

How much does it cost to fix a Baxi H.02-.04 fault in the UK?

If the engineer simply needs to reconfigure the PCB parameters, you are typically paying for the call-out and labour only — expect around £80–£150 all in. If the PCB needs replacing, the part itself usually costs £250–£400 for a Baxi board, plus £100–£150 labour, putting a full replacement in the £350–£500 range for most UK households. In rare cases where an older or discontinued board is difficult to source, costs can edge above £600 — if you are quoted significantly more than that, it is worth getting a second opinion or considering whether a new boiler makes better financial sense, particularly if the boiler is over ten years old.

Why does H.02-.04 appear on a brand new Baxi boiler or after a PCB replacement?

A new PCB — whether fitted in a new boiler or installed as a replacement part — must be programmed with the specific parameters for that boiler model before it will operate. If the installer skipped or did not complete this configuration step, H.02-.04 will appear almost immediately. This is a straightforward fix: the engineer returns and completes the programming. It should be covered at no extra charge if the board was installed recently.

Will my Baxi warranty cover the H.02-.04 fault code repair?

Baxi offers a standard two-year warranty on all new boilers, extendable up to ten years when the boiler is installed by a Baxi-accredited installer and serviced annually. If both conditions are met, PCB faults — including those causing H.02-.04 — are generally covered under the extended warranty. Check your warranty certificate and contact Baxi directly on their customer helpline before booking an independent engineer, as using a non-approved engineer for a warranty repair may affect your cover.

Affected models: Baxi 200 Series, Baxi 400 Series, Baxi 600 Series, Baxi 800 Series, Baxi Platinum, Baxi Duo-tec

Last reviewed 2 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Baxi H.02-.04 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.