Biasi E07 Fault Code: Causes, Fixes & Repair Costs

What does the Biasi E07 fault code mean?

The E07 (also displayed as ER07 on some Biasi models) fault code indicates that the boiler's PCB has detected a problem with the domestic hot water (DHW) NTC temperature sensor — sometimes referred to as the hot water probe. This sensor continuously feeds temperature readings back to the PCB so the boiler can regulate hot water output safely. When those readings fall outside acceptable limits, or stop arriving altogether, the PCB assumes something is wrong and shuts the boiler down into lockout to prevent potential damage. In practical terms: your boiler will stop working and the E07 or ER07 code will sit on the display until the underlying fault is identified and fixed. On some newer Biasi models this fault may appear as E164 or A07, which carries the same meaning — a DHW temperature sensor fault or excessive hot water temperature.

Lockout — engineer likely May need a Gas Safe engineer 7 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Attempt a single boiler reset DIY safe

    Locate the reset button on the Biasi boiler's front panel — it is usually marked with a flame or reset symbol. Press and hold it for around 5–10 seconds until the display changes and the boiler attempts to restart. Allow up to 10 minutes for the boiler to complete its start-up sequence. If the E07 code returns immediately or within a short time, do not keep resetting repeatedly — a reset clears the lockout but does not fix the underlying fault. Move on to the next step.

  2. Check that your gas supply is working DIY safe

    Verify that other gas appliances in your home (such as a gas hob) are working normally. If there is no gas supply to the property, contact your gas supplier rather than an engineer. If other appliances work fine, the gas supply is not the issue here.

  3. Do not attempt to open the boiler casing Gas Safe engineer

    Accessing the DHW NTC probe, wiring, or PCB requires removing the boiler casing. Working inside a gas appliance without Gas Safe registration is illegal in the UK and potentially dangerous. Do not attempt this yourself.

  4. Call a Gas Safe registered engineer to diagnose the fault Gas Safe engineer

    A qualified engineer will use a multimeter to measure the resistance of the DHW NTC probe across its expected temperature range and to test continuity and integrity of the wiring loom. This tells them definitively whether the probe, its wiring, or the PCB is responsible for the E07 code.

  5. Engineer replaces the faulty component Gas Safe engineer

    If the probe is confirmed faulty, it will be replaced with the correct Biasi-compatible NTC sensor. If wiring is the issue, connectors will be resecured or the harness repaired. If limescale is suspected, a descale or powerflush of the secondary heat exchanger may be recommended. In the less common scenario where the PCB is at fault, the engineer will advise on replacement costs versus the age of the boiler.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £140–£320, depending on the underlying cause.

Frequently asked questions

Can I fix the Biasi E07 fault myself?

Unfortunately not. Diagnosing and replacing the DHW NTC probe or any associated wiring requires opening the boiler casing, which legally constitutes work on a gas appliance in the UK. Only a Gas Safe registered engineer is permitted to do this. The one thing you can safely try yourself is a single reset — but if the code comes straight back, stop resetting and call an engineer.

How much does it cost to repair a Biasi E07 fault?

For the most common repair — replacing the DHW NTC temperature sensor and any associated wiring work — most UK homeowners pay somewhere between £140 and £320 including parts and labour. If the fault turns out to be a failed PCB, costs are higher, typically £350–£550 or more depending on the model. On older Biasi boilers, if a PCB quote is approaching £500, it is worth getting a new boiler quote at the same time, as replacement can make more financial sense in the long run.

My boiler shows ER07 rather than E07 — is it the same fault?

Yes, ER07 and E07 refer to the same underlying fault on Biasi boilers. The ER prefix is simply how certain Biasi display panels render the error — the meaning (DHW NTC probe failure) and the fix are identical. Some newer Biasi models may show this fault as E164 or A07, which also indicates a DHW temperature sensor issue.

Will the E07 fault affect my central heating as well as hot water?

Because E07 is specifically linked to the domestic hot water temperature sensor, it primarily affects the hot water circuit. However, because the boiler enters full lockout when E07 triggers, both your hot water and central heating will be unavailable until the fault is cleared. Once the sensor or wiring issue is repaired and the boiler is reset by the engineer, both functions should return to normal.

Affected models: Biasi Riva Plus, Biasi Riva Advance, Biasi Parva, Biasi Garda, Biasi Advance Plus, Biasi M96A, Biasi M90E

Last reviewed 8 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Biasi E07 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →