Biasi E08 Fault Code: Causes, Fixes & Repair Costs

What does the Biasi E08 fault code mean?

The Biasi E08 (also displayed as ER 08) fault code indicates that the boiler's external NTC (Negative Temperature Coefficient) temperature probe has either failed, is producing readings outside the expected range, or has a wiring fault between the sensor and the PCB. NTC sensors are thermistors whose electrical resistance changes predictably with temperature — when the boiler's control board detects a reading that doesn't make sense, or gets no signal at all, it locks out and displays E08. This sensor is only present on systems set up for outdoor weather compensation; if your boiler's PCB is configured to expect an external sensor but none is physically connected, E08 can also appear for that reason.

Engineer may be needed May need a Gas Safe engineer 6 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Attempt a single boiler reset DIY safe

    Locate the reset button on the boiler's front panel — on most Biasi models it is clearly labelled. Press and hold it for approximately 5–10 seconds until the display changes or the boiler begins its restart sequence. Allow up to 10 minutes for the boiler to complete its ignition cycle before deciding whether the fault has cleared. Do not reset more than two or three times in total; repeated resets without an underlying repair will not fix E08 and can mask the true problem.

  2. Check whether an external sensor is physically installed DIY safe

    Have a look outside the property for a small sensor unit — typically a white or grey plastic box — mounted on a north-facing external wall and connected by a thin cable that runs through the wall to the boiler. If you know for certain that no such sensor has ever been fitted, let the engineer know when you call; it may be a simple matter of changing the boiler's configuration settings.

  3. Inspect the sensor cable for obvious damage DIY safe

    If a sensor is fitted, visually check the cable along its route from the sensor to where it enters the building. Look for sections that appear crushed, chafed, or where the outer sheath has been cut. Do not disconnect or interfere with any wiring — this inspection is visual only.

  4. Arrange for a Gas Safe engineer to diagnose the fault Gas Safe engineer

    If the reset does not clear E08, the next steps require a Gas Safe registered engineer. They will use a multimeter to measure the sensor's resistance at various temperatures and compare it against the NTC characteristic curve, inspect all wiring terminations at both the sensor and the PCB, verify the boiler's configuration settings, and confirm whether the sensor, the wiring, or the PCB is at fault before recommending a repair.

  5. Sensor replacement or wiring repair by the engineer Gas Safe engineer

    Once the root cause is confirmed, the engineer will replace the faulty NTC sensor, repair or re-route damaged wiring, or adjust the PCB configuration if no sensor is required on the installation. Biasi external NTC sensors are widely stocked by UK heating merchants and are generally available on next-day delivery, so this is usually a straightforward repair visit.

  6. PCB replacement if all other causes have been ruled out Gas Safe engineer

    If the sensor and wiring both test correctly but E08 persists, the engineer may conclude that the control board is at fault. PCB replacement is a more costly repair and the engineer should confirm the diagnosis carefully before proceeding. For an older Biasi boiler, it is worth asking the engineer whether a new boiler would be a more economical long-term solution at this point.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £120–£280, depending on the underlying cause.

Frequently asked questions

Can I fix Biasi E08 myself without calling an engineer?

The only DIY step that is safe and worthwhile is a single reset. Beyond that, E08 requires electrical testing of the NTC sensor and its wiring, which means using a multimeter on live components and potentially replacing parts — work that should be carried out by a Gas Safe registered engineer. This is not a gas-safety issue in the same way as a gas valve fault, but the electrical diagnostics involved are not suitable for a homeowner to attempt.

My Biasi boiler shows E08 but I don't have an external weather sensor fitted — why?

Some Biasi PCBs are shipped with weather-compensation mode enabled by default, or a previous installer may have configured it that way. If the board is told to look for an external sensor and none is wired in, it will raise E08. A Gas Safe engineer can check the boiler's configuration and disable the external sensor setting if one is not needed on your system — this may resolve the fault without any parts being needed at all.

How much does it typically cost to fix the Biasi E08 fault code?

For the most common repair — replacing the external NTC sensor including parts and labour — most homeowners pay in the region of £120 to £200. If the fault turns out to be damaged wiring rather than the sensor itself, costs are similar. If the PCB is ultimately found to be the cause, a replacement board typically adds £150–£250 to the bill on top of labour, which can push the total towards £350–£400. For an older boiler approaching that level of expenditure, it is worth getting a boiler replacement quote for comparison.

Will the Biasi E08 fault cause my boiler to stop working completely?

It depends on how the boiler is configured. In many cases E08 will cause a lockout, meaning the boiler stops firing until the fault is cleared. In some configurations the boiler may continue to operate but ignore the outdoor sensor, falling back to a fixed flow temperature. Either way, E08 will not resolve itself — the sensor or wiring issue will remain until an engineer investigates and carries out the appropriate repair.

Affected models: Biasi Riva Advance M296.24SM, Biasi Riva Advance M296.28SM, Biasi Riva Plus, Biasi Garda HE, Biasi Parva, Biasi Prisma

Last reviewed 8 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Biasi E08 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →