Biasi E12 Fault Code: Causes, Fixes & Repair Costs

What does the Biasi E12 fault code mean?

The E12 code appears on Biasi boilers when the control board cannot obtain a valid signal from the central heating return temperature sensor — a thermistor known as an NTC (Negative Temperature Coefficient) probe. This probe sits on the return pipe of the primary heat exchanger and continuously feeds temperature data to the PCB so the boiler can regulate heating safely. When the reading falls outside acceptable parameters, or disappears entirely, the boiler locks out and displays E12. On some Biasi models the display alternates between 'Er' and 'RESET', indicating a safety lockout that requires a confirmed repair before normal operation can resume.

Lockout — engineer likely May need a Gas Safe engineer 5 models affected

General guidance only — not a substitute for professional advice, and not certified by a Gas Safe engineer. Always have your specific appliance assessed by a qualified professional. Any gas work must be carried out by a Gas Safe registered engineer. If you smell gas or suspect carbon monoxide, leave the property and call the National Gas Emergency line on 0800 111 999.

Common causes

How to fix it

  1. Check for a gas supply issue first DIY safe

    Before assuming the fault is a failed sensor, confirm that your gas supply is on — check that other gas appliances in your home are working normally. If there is no gas supply, contact your gas supplier rather than an engineer.

  2. Reset the boiler once or twice DIY safe

    Press and hold the reset button (or follow your model's reset procedure as shown in the user manual) to attempt a restart. If E12 clears and the boiler runs normally, monitor it closely. If the code returns within a short time, a reset is not fixing the underlying problem and further resets are unlikely to help.

  3. Do not attempt to access or test the NTC probe yourself Gas Safe engineer

    The return NTC probe is an electrical component mounted on the boiler's primary pipework. Testing it requires disconnecting wiring and measuring resistance with a multimeter against Biasi's specification values. This work must only be carried out by a Gas Safe registered engineer.

  4. Have a Gas Safe engineer inspect the probe wiring Gas Safe engineer

    The engineer will trace the wiring loom from the return probe back to the PCB, checking terminal connections, looking for corrosion, and testing continuity. A loose or corroded connector is sometimes all that is causing the fault.

  5. Have the engineer test the return NTC probe resistance Gas Safe engineer

    With the probe electrically disconnected, the engineer measures its resistance and compares it against the manufacturer's values for a given temperature. A reading that is open-circuit, short-circuit, or far outside the expected range confirms the probe has failed and needs replacing.

  6. Replace the return NTC probe if faulty Gas Safe engineer

    Biasi return NTC probes are a low-cost, widely stocked spare part. Replacement is straightforward for a qualified engineer and in most cases resolves E12 immediately. After fitting, the engineer will reset the boiler, run a heating cycle, and confirm the fault code does not return.

  7. Investigate and flush the system if sludge is suspected Gas Safe engineer

    If the probe tests correctly but the readings were erratic, the engineer may recommend a power flush or a chemical system cleanse to remove sludge, followed by dosing with a quality corrosion inhibitor and fitting a magnetic filter if one is not already present.

  8. Have the PCB tested or replaced if the fault persists Gas Safe engineer

    If a new probe and clean wiring do not clear E12, the control board itself may be at fault. PCB diagnosis and replacement must be carried out by a Gas Safe engineer and is typically the last step in the diagnostic process.

Parts you may need

The exact spare depends on your boiler's GC number (on the data badge). Check this against the part before buying.

Typical repair cost

Expect to pay roughly £150–£280, depending on the underlying cause.

Frequently asked questions

Can I just keep resetting the boiler to clear E12?

Resetting will sometimes get the boiler running briefly, but E12 is a safety lockout that is triggered by a genuine sensor fault — the boiler shuts down to protect itself. Each time the underlying problem is still present, the code will return. Repeated resets without a repair can also mask a developing fault and delay the right fix, so it is best to call a Gas Safe engineer after the first one or two unsuccessful resets.

How much does it cost to fix a Biasi E12 fault?

For most homeowners, the repair involves replacing the return NTC probe — a cheap part — plus an engineer call-out and an hour or so of labour. Expect to pay roughly £150–£280 in total. If the PCB turns out to be the cause rather than the probe, the control board itself can cost £150–£250 for the part alone, pushing the overall bill higher, but this outcome is comparatively uncommon.

Is my Biasi boiler still under warranty?

Biasi offers warranties of five to seven years depending on the model and registration. If your boiler is within that period, contact Biasi directly before paying for a repair — a valid warranty may cover both parts and labour. You will usually need proof of annual servicing to keep the warranty intact.

What can I do to prevent the E12 fault coming back?

The best preventive measure is an annual service by a Gas Safe engineer, during which the probes and wiring are inspected and connection quality is checked. Keeping your heating circuit clean with a quality inhibitor and a magnetic filter reduces the sludge build-up that can coat and degrade NTC probes over time. Bleeding radiators annually and maintaining the correct system pressure also helps the boiler run efficiently with less thermal stress on its components.

Affected models: Biasi Rinnova, Biasi Riva, Biasi Advance, Biasi M90, Biasi Parva

Last reviewed 8 July 2026 · verified by our team.

Are you a heating engineer? Join our network and get local jobs sent to you.

Find a Gas Safe engineer

✓ Your boiler details: Biasi E12 — one step done already.

We pass your details to up to 3 vetted local engineers. No payment is taken here.

Can't find your boiler or fault code?

Tell us what you need — we'll help, and we can put you in touch with a Gas Safe registered engineer.

Get in touch →